Search Results (412 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-73167 1 Advantech 2 Eki-1242eims, Eki-1242ieims 2026-09-18 N/A
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in the web management interface of Advantech EKI-1242IEIMS in firmware version V1.06.01 that allows a remote authenticated attacker to execute arbitrary OS commands as root via crafted request parameters.
CVE-2026-73164 1 Advantech 2 Eki-1242eims, Eki-1242ieims 2026-09-18 N/A
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in the web management interface of Advantech EKI-1242IEIMS in firmware version V1.06.01 that allows a remote authenticated attacker to execute arbitrary OS commands as root via crafted request parameters.
CVE-2026-73165 1 Advantech 2 Eki-1242eims, Eki-1242ieims 2026-09-18 N/A
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in the web management interface of Advantech EKI-1242IEIMS in firmware version V1.06.01 that allows a remote authenticated attacker to execute arbitrary OS commands as root via crafted request parameters.
CVE-2026-73170 1 Advantech 2 Eki-1242eims, Eki-1242ieims 2026-09-18 N/A
Nozomi Networks Labs identified a CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability in the Modbus CSV import workflow of Advantech EKI-1242EIMS in firmware version V1.06.01 that allows a remote authenticated attacker to execute arbitrary Lua code on the device via a crafted imported file.
CVE-2026-73173 1 Advantech 2 Eki-1242eims, Eki-1242ieims 2026-09-18 N/A
Nozomi Networks Labs identified a CWE-306: Missing Authentication for Critical Function vulnerability in the edgserver management protocol of Advantech EKI-1242EIMS in firmware version V1.06.01 that allows a remote unauthenticated attacker to invoke critical device-management functions, including network reconfiguration, reboot, reset, and firmware upgrade, by sending crafted requests to TCP port 5058.
CVE-2026-73176 1 Advantech 2 Eki-1242eims, Eki-1242ieims 2026-09-18 N/A
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in the web management interface of Advantech EKI-1242IEIMS in firmware version V1.06.01 that allows a remote authenticated attacker to execute arbitrary OS commands as root via crafted request parameters.
CVE-2026-19535 1 Advantech 2 Eki-1242eims, Eki-1242ieims 2026-09-18 N/A
Nozomi Networks Labs identified a CWE-352: Cross-Site Request Forgery (CSRF) vulnerability in the LuCI administrative web interface of Advantech EKI-1242IEIMS in firmware version V1.06.01 that allows a remote unauthenticated attacker to perform unauthorized state-changing requests on behalf of a logged-in administrator, enabling unauthorized access to privileged management functions.
CVE-2026-73163 1 Advantech 2 Eki-1242eims, Eki-1242ieims 2026-09-18 N/A
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in the web management interface of Advantech EKI-1242IEIMS in firmware version V1.06.01 that allows a remote authenticated attacker to execute arbitrary OS commands as root via crafted request parameters.
CVE-2026-73166 1 Advantech 2 Eki-1242eims, Eki-1242ieims 2026-09-18 N/A
Nozomi Networks Labs identified a CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability in the web management interface of Advantech EKI-1242IEIMS in firmware version V1.06.01 that allows a remote authenticated attacker to execute arbitrary code on the device, including OS commands as root.
CVE-2026-73171 1 Advantech 2 Eki-1242eims, Eki-1242ieims 2026-09-18 N/A
Nozomi Networks Labs identified a CWE-73: External Control of File Name or Path vulnerability in the backup-restore workflow of Advantech EKI-1242EIMS in firmware version V1.06.01 that allows a remote authenticated attacker to overwrite arbitrary files on the device filesystem by uploading a crafted backup archive through the web management interface.
CVE-2026-73172 1 Advantech 2 Eki-1242eims, Eki-1242ieims 2026-09-18 N/A
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in the edgserver management service of Advantech EKI-1242EIMS in firmware version V1.06.01 that allows a remote unauthenticated attacker to execute arbitrary OS commands as root via crafted requests to TCP port 5058.
CVE-2026-73175 1 Advantech 2 Eki-1242eims, Eki-1242ieims 2026-09-18 N/A
Nozomi Networks Labs identified a CWE-400: Uncontrolled Resource Consumption vulnerability in the OPC UA gateway component of Advantech EKI-1242EIMS in firmware version V1.06.01 that allows an adjacent unauthenticated attacker to exhaust the server session pool and cause a complete denial of service to all legitimate OPC UA clients by opening multiple anonymous sessions.
CVE-2026-73177 1 Advantech 2 Eki-1242eims, Eki-1242ieims 2026-09-18 N/A
Nozomi Networks Labs identified a CWE-345: Insufficient Verification of Data Authenticity vulnerability in the firmware upgrade mechanism of the Advantech EKI-1242EIMS in firmware version V1.06.01. The device accepts firmware images through the authenticated web management interface without performing any cryptographic signature or certificate verification. An authenticated administrator-level attacker can install arbitrary modified firmware on the device, enabling full persistent compromise of the platform.
CVE-2026-73169 1 Advantech 2 Eki-1242eims, Eki-1242ieims 2026-09-17 N/A
Nozomi Networks Labs identified a CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Modbus transaction management interface of Advantech EKI-1242EIMS in firmware version V1.06.01 that allows a remote authenticated attacker to store malicious script content that executes in the browser of any administrator who later opens an affected management page.
CVE-2026-73174 1 Advantech 2 Eki-1242eims, Eki-1242ieims 2026-09-17 N/A
Nozomi Networks Labs identified a CWE-319: Cleartext Transmission of Sensitive Information vulnerability in the edgserver management protocol of Advantech EKI-1242EIMS in firmware version V1.06.01 that allows a network-adjacent passive observer to intercept management traffic and recover sensitive device identity and network metadata in cleartext.
CVE-2026-79698 1 Advantech 14 Wise-6610, Wise-6610-cb, Wise-6610-eb and 11 more 2026-09-11 9.9 Critical
A vulnerability was identified in Advantech WISE-6610-NB, WISE-6610-EB, WISE-6610-TB, WISE-6610-JB, WISE-6610-CB, WISE-6610-EL-NB, WISE-6610-EL-EB, WISE-6610-EL-TB, WISE-6610-EL-JB, WISE-6610-EL-CB, WISE-6610P-DEA, WISE-6610P-DNA and WISE-6610P-DTA 1.2.1_20251110. This vulnerability affects the function nodered_lib_apply of the component Node-RED Library. Such manipulation of the argument act leads to command injection. The attack can be launched remotely. The exploit is publicly available and might be used. Upgrading to version 1.2.4_20260821 is able to resolve this issue. It is advisable to upgrade the affected component. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.
CVE-2026-43833 1 Advantech 1 Adam-3600 2026-09-11 5.3 Medium
Full details and mitigation steps are currently restricted and will be published at a later date.
CVE-2026-43832 1 Advantech 1 Adam-3600 2026-09-11 7.5 High
Full details and mitigation steps are currently restricted and will be published at a later date.
CVE-2026-43831 1 Advantech 1 Adam-3600 2026-09-11 7.5 High
Full details and mitigation steps are currently restricted and will be published at a later date.
CVE-2026-43830 1 Advantech 1 Adam-3600 2026-09-11 9.8 Critical
Full details and mitigation steps are currently restricted and will be published at a later date.