| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The Control Panel in Parallels Plesk Panel 10.4.4_build20111103.18 sends incorrect Content-Type headers for certain resources, which might allow remote attackers to have an unspecified impact by leveraging an interpretation conflict involving admin/health/parameters and certain other files. NOTE: it is possible that only clients, not the Plesk product, could be affected by this issue. |
| Heap-based buffer overflow in the in_mod.dll plugin in Winamp before 5.623 allows remote attackers to execute arbitrary code via crafted song message data in an Impulse Tracker (IT) file. NOTE: some of these details are obtained from third party information. |
| The Schneider Electric Quantum Ethernet Module, as used in the Quantum 140NOE771* and 140CPU65* modules, the Premium TSXETY* and TSXP57* modules, the M340 BMXNOE01* and BMXP3420* modules, and the STB DIO STBNIC2212 and STBNIP2* modules, uses hardcoded passwords for the (1) AUTCSE, (2) AUT_CSE, (3) fdrusers, (4) ftpuser, (5) loader, (6) nic2212, (7) nimrohs2212, (8) nip2212, (9) noe77111_v500, (10) ntpupdate, (11) pcfactory, (12) sysdiag, (13) target, (14) test, (15) USER, and (16) webserver accounts, which makes it easier for remote attackers to obtain access via the (a) TELNET, (b) Windriver Debug, or (c) FTP port. |
| Buffer overflow in libtelnet/encrypt.c in telnetd in FreeBSD 7.3 through 9.0, MIT Kerberos Version 5 Applications (aka krb5-appl) 1.0.2 and earlier, Heimdal 1.5.1 and earlier, GNU inetutils, and possibly other products allows remote attackers to execute arbitrary code via a long encryption key, as exploited in the wild in December 2011. |
| The Tencent QQPimSecure (com.tencent.qqpimsecure) application 3.0.2 for Android does not properly protect data, which allows remote attackers to read or modify SMS/MMS messages and a contact list via a crafted application. |
| The Tencent MobileQQ (com.tencent.mobileqq) application 2.2 for Android does not properly protect data, which allows remote attackers to read or modify messages and a friends list via a crafted application. |
| The Tencent WBlog (com.tencent.WBlog) 3.3.1 and MicroBlogPad 1.4.0 applications for Android do not properly protect data, which allows remote attackers to read or modify message drafts and search keywords via a crafted application. |
| The Tencent QQPhoto (com.tencent.qqphoto) application 0.97 for Android does not properly protect data, which allows remote attackers to read or modify contact information and a password hash via a crafted application. |
| Multiple HTC Android devices including Desire HD FRG83D and GRI40, Glacier FRG83, Droid Incredible FRF91, Thunderbolt 4G FRG83D, Sensation Z710e GRI40, Sensation 4G GRI40, Desire S GRI40, EVO 3D GRI40, and EVO 4G GRI40 allow remote attackers to obtain 802.1X Wi-Fi credentials and SSID via a crafted application that uses the android.permission.ACCESS_WIFI_STATE permission to call the toString method on the WifiConfiguration class. |
| Unspecified vulnerability in the server in Certec EDV atvise before 2.1 allows remote attackers to cause a denial of service (daemon crash) via crafted requests to TCP port 4840. |
| Open Automation Software OPC Systems.NET before 5.0 allows remote attackers to cause a denial of service via a malformed .NET RPC packet on TCP port 58723. |
| Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute arbitrary code via vectors related to Unicode strings. |
| Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string. |
| HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cause a denial of service (application crash) by sending crafted data over TCP. |
| Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI. |
| miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request. |
| The server in IBM solidDB 6.5 before FP9 and 7.0 before FP1 allows remote authenticated users to cause a denial of service (daemon crash) via a SELECT statement with a ROWNUM condition involving a subquery. |
| Tor before 0.2.2.34, when configured as a bridge, uses direct DirPort access instead of a Tor TLS connection for a directory fetch, which makes it easier for remote attackers to enumerate bridges by observing DirPort connections. |
| Tor before 0.2.2.34, when configured as a bridge, sets up circuits through a process different from the process used by a client, which makes it easier for remote attackers to enumerate bridges by observing circuit building. |
| Tor before 0.2.2.24-alpha continues to use a reachable bridge that was previously configured but is not currently configured, which might allow remote attackers to obtain sensitive information about clients in opportunistic circumstances by monitoring network traffic to the bridge port. |