| Triangle Research International (aka Tri) Nano-10 PLC devices with firmware before r81 use an incorrect algorithm for bounds checking of data in Modbus/TCP packets, which allows remote attackers to cause a denial of service (networking outage) via a crafted packet to TCP port 502. |
| Multiple buffer overflows in CimWebServer.exe in the WebView component in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY before 8.0 SIM 27, 8.1 before SIM 25, and 8.2 before SIM 19, and Proficy Process Systems with CIMPLICITY, allow remote attackers to execute arbitrary code via crafted data in packets to TCP port 10212, aka ZDI-CAN-1621 and ZDI-CAN-1624. |
| Alstom Grid MiCOM S1 Agile before 1.0.3 and Alstom Grid MiCOM S1 Studio use weak permissions for the MiCOM S1 %PROGRAMFILES% directory, which allows local users to gain privileges via a Trojan horse executable file. |
| Alstom e-terracontrol 3.5, 3.6, and 3.7 allows remote attackers to cause a denial of service (infinite loop) via crafted DNP3 packets. |
| The DNP3 Slave service in SUBNET Solutions SubSTATION Server 2.7.0033 and 2.8.0106 allows remote attackers to cause a denial of service (unhandled exception and process crash) via unspecified vectors. |
| The Kepware DNP Master Driver for the KEPServerEX Communications Platform before 5.12.140.0 allows remote attackers to cause a denial of service (master-station infinite loop) via crafted DNP3 packets to TCP port 20000 and allows physically proximate attackers to cause a denial of service (master-station infinite loop) via crafted input over a serial line. |
| MatrikonOPC SCADA DNP3 OPC Server 1.2.0 allows remote attackers to cause a denial of service (master-station daemon crash) via a malformed DNP3 TCP packet from the IP address of an outstation. |
| Schweitzer Engineering Laboratories (SEL) SEL-2241, SEL-3505, and SEL-3530 RTAC master devices allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet. |
| Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet. |
| Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line. |
| The OSIsoft PI Interface for IEEE C37.118 before 1.0.6.158 allows remote attackers to cause a denial of service (memory consumption or memory corruption, instance shutdown, and data-collection outage) via crafted C37.118 configuration packets. |
| The OSIsoft PI Interface for IEEE C37.118 before 1.0.6.158 allows remote attackers to cause a denial of service (instance shutdown and data-collection outage) via crafted C37.118 configuration packets that trigger an invalid read operation. |
| The universal protocol implementation in Sixnet UDR before 2.0 and RTU firmware before 4.8 allows remote attackers to execute arbitrary code; read, modify, or create files; or obtain file metadata via function opcodes. |
| ProSoft RadioLinx ControlScape before 6.00.040 uses a deficient PRNG algorithm and seeding strategy for passphrases, which makes it easier for remote attackers to obtain access via a brute-force attack. |
| Schweitzer Engineering Laboratories (SEL) SEL-2241, SEL-3505, and SEL-3530 RTAC master devices allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line. |
| The DNP Master Driver in Software Toolbox TOP Server before 5.12.140.0 allows remote attackers to cause a denial of service (master-station infinite loop) via crafted DNP3 packets to TCP port 20000 and allows physically proximate attackers to cause a denial of service (master-station infinite loop) via crafted input over a serial line. |
| Heap-based buffer overflow in Xper in Philips Xper Information Management Physiomonitoring 5 components, Xper Information Management Vascular Monitoring 5 components, and Xper Information Management servers and workstations for Flex Cardio products before XperConnect 1.5.4.053 SP2 allows remote attackers to execute arbitrary code via a crafted HTTP request to the Connect broker on TCP port 6000. |
| The (1) Catapult DNP3 I/O driver before 7.2.0.60 and the (2) GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrv.exe (aka the DNP master station server) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY and iFIX, allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet. |
| The DNP3 component in Cooper Power Systems SMP 4, 4/DP, and 16 gateways allows remote attackers to cause a denial of service (reboot or link outage) via a crafted DNP3 TCP packet. |
| Cooper Power Systems Cybectec DNP3 Master OPC Server allows remote attackers to cause a denial of service (unhandled exception and process crash) via unspecified vectors. |