| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Baker Hughes – Bently Nevada 3500 System TDI Firmware version 5.05
contains a vulnerability in their password retrieval functionality which could allow an attacker to access passwords stored on the device. |
|
Baker Hughes – Bently Nevada 3500 System TDI Firmware version 5.05
contains a replay vulnerability which could allow an attacker to
replay older captured packets of traffic to the device to gain access.
|
|
Santesoft Sante FFT Imaging lacks proper validation of user-supplied data when parsing DICOM files. This could lead to an out-of-bounds read. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process. |
|
Sante DICOM Viewer Pro lacks proper validation of user-supplied data when parsing DICOM files. This could lead to an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process.
|
|
Sante DICOM Viewer Pro lacks proper validation of user-supplied data when parsing DICOM files. This could lead to a stack-based buffer overflow. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process.
|
|
In Weintek's cMT3000 HMI Web CGI device, the cgi-bin command_wb.cgi contains a stack-based buffer overflow, which could allow an anonymous attacker to hijack control flow and bypass login authentication.
|
|
In Weintek's cMT3000 HMI Web CGI device, an anonymous attacker can execute arbitrary commands after login to the device.
|
|
In Weintek's cMT3000 HMI Web CGI device, the cgi-bin codesys.cgi contains a stack-based buffer overflow, which could allow an anonymous attacker to hijack control flow and bypass login authentication.
|
| The cookie session ID is of insufficient length and can be exploited by
brute force, which may allow a remote attacker to obtain a valid
session, bypass authentication, and manipulate the transmitter.
|
|
The application interface allows users to perform certain actions via
HTTP requests without performing any validity checks to verify the
requests. This can be exploited to perform certain actions with
administrative privileges if a logged-in user visits a malicious web
site.
|
|
The application suffers from improper access control when editing users.
A user with read permissions can manipulate users, passwords, and
permissions by sending a single HTTP POST request with modified
parameters.
|
|
The application suffers from a privilege escalation vulnerability. A
user with read permissions can elevate privileges by sending a HTTP POST
to set a parameter.
|
|
Sielco PolyEco1000 is vulnerable to a session hijack vulnerability due to the cookie being vulnerable to a brute force attack, lack of SSL, and the session being visible in requests.
|
|
Sielco PolyEco1000 uses a weak set of default administrative credentials that can be easily guessed in remote password attacks and gain full control of the system.
|
|
Sielco PolyEco1000 is vulnerable to an attacker escalating their privileges by modifying passwords in POST requests.
|
|
Sielco PolyEco1000 is vulnerable to an information disclosure vulnerability due to improper access control enforcement. An unauthenticated remote attacker can exploit this via a specially crafted request to gain access to sensitive information.
|
|
Sielco PolyEco1000 is vulnerable to an attacker bypassing authorization and accessing resources behind protected pages. The application interface allows users to perform certain actions via HTTP requests without performing any validity checks to verify the requests.
|
|
Sielco PolyEco1000 is vulnerable to an improper access control vulnerability when the application provides direct access to objects based on user-supplied input. As a result of this vulnerability attackers can bypass authorization and access resources behind protected pages.
|
|
Sielco PolyEco1000 is vulnerable to an authentication bypass vulnerability due to an attacker modifying passwords in a POST request and gain unauthorized access to the affected device with administrative privileges.
|
|
Weintek EasyBuilder Pro contains a vulnerability that, even when the private key is immediately deleted after the crash report transmission is finished, the private key is exposed to the public, which could result in obtaining remote control of the crash report server.
|