| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
|
In Weintek's cMT3000 HMI Web CGI device, the cgi-bin codesys.cgi contains a stack-based buffer overflow, which could allow an anonymous attacker to hijack control flow and bypass login authentication.
|
| The cookie session ID is of insufficient length and can be exploited by
brute force, which may allow a remote attacker to obtain a valid
session, bypass authentication, and manipulate the transmitter.
|
|
The application interface allows users to perform certain actions via
HTTP requests without performing any validity checks to verify the
requests. This can be exploited to perform certain actions with
administrative privileges if a logged-in user visits a malicious web
site.
|
|
The application suffers from improper access control when editing users.
A user with read permissions can manipulate users, passwords, and
permissions by sending a single HTTP POST request with modified
parameters.
|
|
The application suffers from a privilege escalation vulnerability. A
user with read permissions can elevate privileges by sending a HTTP POST
to set a parameter.
|
|
Sielco PolyEco1000 is vulnerable to a session hijack vulnerability due to the cookie being vulnerable to a brute force attack, lack of SSL, and the session being visible in requests.
|
|
Sielco PolyEco1000 uses a weak set of default administrative credentials that can be easily guessed in remote password attacks and gain full control of the system.
|
|
Sielco PolyEco1000 is vulnerable to an attacker escalating their privileges by modifying passwords in POST requests.
|
|
Sielco PolyEco1000 is vulnerable to an information disclosure vulnerability due to improper access control enforcement. An unauthenticated remote attacker can exploit this via a specially crafted request to gain access to sensitive information.
|
|
Sielco PolyEco1000 is vulnerable to an attacker bypassing authorization and accessing resources behind protected pages. The application interface allows users to perform certain actions via HTTP requests without performing any validity checks to verify the requests.
|
|
Sielco PolyEco1000 is vulnerable to an improper access control vulnerability when the application provides direct access to objects based on user-supplied input. As a result of this vulnerability attackers can bypass authorization and access resources behind protected pages.
|
|
Sielco PolyEco1000 is vulnerable to an authentication bypass vulnerability due to an attacker modifying passwords in a POST request and gain unauthorized access to the affected device with administrative privileges.
|
|
Weintek EasyBuilder Pro contains a vulnerability that, even when the private key is immediately deleted after the crash report transmission is finished, the private key is exposed to the public, which could result in obtaining remote control of the crash report server.
|
|
The Crimson 3.2 Windows-based configuration tool allows users with administrative access to define new passwords for users and to download the resulting security configuration to a device. If such a password contains the percent (%) character, invalid values will be included, potentially truncating the string if a NUL is encountered. If the simplified password is not detected by the administrator, the device might be left in a vulnerable state as a result of more-easily compromised credentials. Note that passwords entered via the Crimson system web server do not suffer from this vulnerability.
|
|
General Electric MiCOM S1 Agile is vulnerable to an attacker achieving code execution by placing malicious DLL files in the directory of the application.
|
| Zavio CF7500, CF7300, CF7201, CF7501, CB3211, CB3212, CB5220,
CB6231, B8520, B8220, and CD321
IP Cameras
with firmware version M2.1.6.05 has a
command injection vulnerability in their implementation of their
binaries and handling of network requests.
|
| Zavio CF7500, CF7300, CF7201, CF7501, CB3211, CB3212, CB5220,
CB6231, B8520, B8220, and CD321 IP Cameras
with firmware version M2.1.6.05 are
vulnerable to stack-based overflows. During the process of updating
certain settings sent from incoming network requests, the product does
not sufficiently check or validate allocated buffer size. This may lead
to remote code execution.
|
| Zavio CF7500, CF7300, CF7201, CF7501, CB3211, CB3212, CB5220,
CB6231, B8520, B8220, and CD321
IP Cameras
with firmware version M2.1.6.05 are
vulnerable to multiple instances of stack-based overflows. During the
processing and parsing of certain fields in XML elements from incoming
network requests, the product does not sufficiently check or validate
allocated buffer size. This may lead to remote code execution.
|
| Zavio CF7500, CF7300, CF7201, CF7501, CB3211, CB3212, CB5220,
CB6231, B8520, B8220, and CD321
IP CamerasĀ with firmware version M2.1.6.05 are
vulnerable to multiple instances of stack-based overflows. While parsing
certain XML elements from incoming network requests, the product does
not sufficiently check or validate allocated buffer size. This may lead
to remote code execution.
|
| Zavio CF7500, CF7300, CF7201, CF7501, CB3211, CB3212, CB5220,
CB6231, B8520, B8220, and CD321
IP Cameras
with firmware version M2.1.6.05 are
vulnerable to multiple instances of stack-based overflows. While
processing XML elements from incoming network requests, the product does
not sufficiently check or validate allocated buffer size. This may lead
to remote code execution.
|