| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The affected On-Premise cnMaestro is vulnerable to an arbitrary file-write through improper limitation of a pathname to a restricted directory inside a specific route. If an attacker supplied path traversal charters (../) as part of a filename, the server will save the file where the attacker chooses. This could allow an attacker to write any data to any file in the server. |
| The affected On-Premise cnMaestro is vulnerable to execution of code on the cnMaestro hosting server. This could allow a remote attacker to change server configuration settings. |
| The affected On-Premise cnMaestro is vulnerable inside a specific route where a user can upload a crafted package to the system. An attacker could abuse this user-controlled data to execute arbitrary commands on the server. |
| Inkscape 0.91 is vulnerable to an out-of-bounds read, which may allow an attacker to have access to unauthorized information. |
| Inkscape version 0.91 can access an uninitialized pointer, which may allow an attacker to have access to unauthorized information. |
| Inkscape version 0.91 is vulnerable to an out-of-bounds write, which may allow an attacker to arbitrary execute code. |
| A malicious attacker could exploit the interface of the Fieldcomm Group HART-IP (release 1.0.0.0) by constructing messages with sufficiently large payloads to overflow the internal buffer and crash the device, or obtain control of the device. |
| The affected ThroughTek P2P products (SDKs using versions before 3.1.5, any versions with nossl tag, device firmware not using AuthKey for IOTC conneciton, firmware using AVAPI module without enabling DTLS mechanism, and firmware using P2PTunnel or RDT module) do not sufficiently protect data transferred between the local device and ThroughTek servers. This can allow an attacker to access sensitive information, such as camera feeds. |
| The main MiCODUS MV720 GPS tracker web server has an authenticated insecure direct object reference vulnerability on endpoint and parameter device IDs, which accept arbitrary device IDs without further verification. |
| SMS-based GPS commands can be executed by MiCODUS MV720 GPS tracker without authentication. |
| The main MiCODUS MV720 GPS tracker web server has an authenticated insecure direct object references vulnerability on endpoint and POST parameter “Device ID,” which accepts arbitrary device IDs. |
| The MiCODUS MV720 GPS tracker API server has an authentication mechanism that allows devices to use a hard-coded master password. This may allow an attacker to send SMS commands directly to the GPS tracker as if they were coming from the GPS owner’s mobile number. |
| The affected product may allow an attacker with access to the Ignition web configuration to run arbitrary code. |
| The X-Frame-Options header in Rockwell Automation MicroLogix 1100/1400 Versions 21.007 and prior is not configured in the HTTP response, which could allow clickjacking attacks. |
| Due to an XML external entity reference, the software parses XML in the backup/restore functionality without XML security flags, which may lead to a XXE attack while restoring the backup. |
| An attacker may be able to execute malicious actions due to the lack of device access protections and device permissions when using the web application. This could lead to uploading python files which can be later executed. |
| AutomationDirect C-more EA9 HTTP webserver uses an insecure mechanism to transport credentials from client to web server, which may allow an attacker to obtain the login credentials and login as a valid user. This issue affects: AutomationDirect C-more EA9 EA9-T6CL versions prior to 6.73; EA9-T6CL-R versions prior to 6.73; EA9-T7CL versions prior to 6.73; EA9-T7CL-R versions prior to 6.73; EA9-T8CL versions prior to 6.73; EA9-T10CL versions prior to 6.73; EA9-T10WCL versions prior to 6.73; EA9-T12CL versions prior to 6.73; EA9-T15CL versions prior to 6.73; EA9-RHMI versions prior to 6.73; EA9-PGMSW versions prior to 6.73; |
| Delta Electronics CNCSoft (All versions prior to 1.01.32) does not properly sanitize input while processing a specific project file, allowing a possible out-of-bounds read condition. |
| Passwords are not adequately encrypted during the communication process between all versions of LS Industrial Systems (LSIS) Co. Ltd LS Electric XG5000 software prior to V4.0 and LS Electric PLCs: all versions of XGK-CPUU/H/A/S/E prior to V3.50, all versions of XGI-CPUU/UD/H/S/E prior to V3.20, all versions of XGR-CPUH prior to V1.80, all versions of XGB-XBMS prior to V3.00, all versions of XGB-XBCH prior to V1.90, and all versions of XGB-XECH prior to V1.30. This would allow an attacker to identify and decrypt the password of the affected PLCs by sniffing the PLC’s communication traffic. |
| Delta Electronics Delta Robot Automation Studio (DRAS) versions prior to 1.13.20 are affected by improper restrictions where the software processes an XML document that can contain XML entities with URIs that resolve to documents outside of the intended sphere of control, causing the product to embed incorrect documents into its output. This may allow an attacker to view sensitive documents and information on the affected host. |