Search Results (2349 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2011-20002 1 Siemens 3 Simatic, Simatic S7-1200, Simatic S7-1200 Cpu 2026-04-15 7.4 High
A vulnerability has been identified in SIMATIC S7-1200 CPU V1 family (incl. SIPLUS variants) (All versions < V2.0.2), SIMATIC S7-1200 CPU V2 family (incl. SIPLUS variants) (All versions < V2.0.2). Affected controllers are vulnerable to capture-replay in the communication with the engineering software. This could allow an on-path attacker between the engineering software and the controller to execute any previously recorded commands at a later time (e.g. set the controller to STOP), regardless whether or not the controller had a password configured.
CVE-2025-40744 1 Siemens 1 Solid Edge Se2025 2026-04-15 7.5 High
A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 11). Affected applications do not properly validate client certificates to connect to License Service endpoint. This could allow an unauthenticated remote attacker to perform man in the middle attacks.
CVE-2025-40827 1 Siemens 2 Software Center, Solid Edge Se2025 2026-04-15 7.8 High
A vulnerability has been identified in Siemens Software Center (All versions < V3.5), Solid Edge SE2025 (All versions < V225.0 Update 10). The affected application is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code via placing a crafted DLL file on the system.
CVE-2024-43647 1 Siemens 14 Simatic S7-200 Smart Cpu Cr20s, Simatic S7-200 Smart Cpu Cr30s, Simatic S7-200 Smart Cpu Cr40 and 11 more 2026-04-15 7.5 High
A vulnerability has been identified in SIMATIC S7-200 SMART CPU CR40 (6ES7288-1CR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU CR60 (6ES7288-1CR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA1) (All versions). Affected devices do not properly handle TCP packets with an incorrect structure. This could allow an unauthenticated remote attacker to cause a denial of service condition. To restore normal operations, the network cable of the device needs to be unplugged and re-plugged.
CVE-2025-40771 1 Siemens 6 Simatic Cp 1542sp-1, Simatic Cp 1542sp-1 Irc, Simatic Cp 1543sp-1 and 3 more 2026-04-15 9.8 Critical
A vulnerability has been identified in SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.4.24). Affected devices do not properly authenticate configuration connections. This could allow an unauthenticated remote attacker to access the configuration data.
CVE-2024-37997 1 Siemens 2 Jt Open, Plm Xml Sdk 2026-04-15 7.8 High
A vulnerability has been identified in JT Open (All versions < V11.5), JT2Go (All versions < V2406.0003), PLM XML SDK (All versions < V7.1.0.014), Teamcenter Visualization V14.2 (All versions < V14.2.0.13), Teamcenter Visualization V14.3 (All versions < V14.3.0.11), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0003). The affected applications contain a stack based overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process.
CVE-2024-41981 1 Siemens 1 Simcenter Nastran 2026-04-15 7.8 High
A vulnerability has been identified in Simcenter Femap V2306 (All versions), Simcenter Femap V2401 (All versions), Simcenter Femap V2406 (All versions). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted BDF files. This could allow an attacker to execute code in the context of the current process.
CVE-2025-40805 1 Siemens 24 Industrial Edge Cloud Device (iecd), Industrial Edge Device Kit, Industrial Edge Own Device (ieod) and 21 more 2026-04-15 10 Critical
Affected devices do not properly enforce user authentication on specific API endpoints. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that the attacker has learned the identity of a legitimate user.
CVE-2024-33698 1 Siemens 4 Simatic Information Server, Simatic Pcs Neo, Sinec Nms and 1 more 2026-04-15 9.8 Critical
A vulnerability has been identified in Opcenter Quality (All versions < V2406), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions), SINEMA Remote Connect Client (All versions < V3.2 SP3), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 5), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 3). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code.
CVE-2024-38278 1 Siemens 32 Ruggedcom Ros Rmc8388, Ruggedcom Ros Rmc8388nc, Ruggedcom Ros Rs416ncv2 and 29 more 2026-04-15 6.6 Medium
A vulnerability has been identified in RUGGEDCOM RMC8388 V5.X (All versions < V5.9.0), RUGGEDCOM RMC8388NC V5.X (All versions < V5.9.0), RUGGEDCOM RS416NCv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416PNCv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416v2 V5.X (All versions < V5.9.0), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.9.0), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.9.0), RUGGEDCOM RS900GNC(32M) V5.X (All versions < V5.9.0), RUGGEDCOM RS900NC(32M) V5.X (All versions < V5.9.0), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.9.0), RUGGEDCOM RSG2100NC(32M) V5.X (All versions < V5.9.0), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.9.0), RUGGEDCOM RSG2100PNC (32M) V5.X (All versions < V5.9.0), RUGGEDCOM RSG2288 V5.X (All versions < V5.9.0), RUGGEDCOM RSG2288NC V5.X (All versions < V5.9.0), RUGGEDCOM RSG2300 V5.X (All versions < V5.9.0), RUGGEDCOM RSG2300NC V5.X (All versions < V5.9.0), RUGGEDCOM RSG2300P V5.X (All versions < V5.9.0), RUGGEDCOM RSG2300PNC V5.X (All versions < V5.9.0), RUGGEDCOM RSG2488 V5.X (All versions < V5.9.0), RUGGEDCOM RSG2488NC V5.X (All versions < V5.9.0), RUGGEDCOM RSG907R (All versions < V5.9.0), RUGGEDCOM RSG908C (All versions < V5.9.0), RUGGEDCOM RSG909R (All versions < V5.9.0), RUGGEDCOM RSG910C (All versions < V5.9.0), RUGGEDCOM RSG920P V5.X (All versions < V5.9.0), RUGGEDCOM RSG920PNC V5.X (All versions < V5.9.0), RUGGEDCOM RSL910 (All versions < V5.9.0), RUGGEDCOM RSL910NC (All versions < V5.9.0), RUGGEDCOM RST2228 (All versions < V5.9.0), RUGGEDCOM RST2228P (All versions < V5.9.0), RUGGEDCOM RST916C (All versions < V5.9.0), RUGGEDCOM RST916P (All versions < V5.9.0). The affected products with IP forwarding enabled wrongly make available certain remote services in non-managed VLANs, even if these services are not intentionally activated. An attacker could leverage this vulnerability to create a remote shell to the affected system.
CVE-2011-20001 1 Siemens 3 Simatic, Simatic S7-1200, Simatic S7-1200 Cpu 2026-04-15 7.5 High
A vulnerability has been identified in SIMATIC S7-1200 CPU V1 family (incl. SIPLUS variants) (All versions < V2.0.3), SIMATIC S7-1200 CPU V2 family (incl. SIPLUS variants) (All versions < V2.0.3). The web server interface of affected devices improperly processes incoming malformed HTTP traffic at high rate. This could allow an unauthenticated remote attacker to force the device entering the stop/defect state, thus creating a denial of service condition.
CVE-2024-33498 1 Siemens 1 Simatic Rtls Locating Manager 2026-04-15 5.3 Medium
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected applications do not properly release memory that is allocated when handling specifically crafted incoming packets. This could allow an unauthenticated remote attacker to cause a denial of service condition by crashing the service when it runs out of memory. The service is restarted automatically after a short time.
CVE-2023-7066 1 Siemens 2 Jt2go, Teamcenter Visualization 2026-04-15 7.8 High
The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process.
CVE-2024-30321 1 Siemens 3 Simatic Pcs 7, Simatic Wincc, Simatic Wincc Runtime Professional 2026-04-15 5.9 Medium
A vulnerability has been identified in SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 23), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products do not properly handle certain requests to their web application, which may lead to the leak of privileged information. This could allow an unauthenticated remote attacker to retrieve information such as users and passwords.
CVE-2024-31484 1 Siemens 2 Cpc80 Central Processing\/communication, Cpci85 Central Processing\/communication 2026-04-15 7.8 High
A vulnerability has been identified in CPC80 Central Processing/Communication (All versions < V16.41), CPCI85 Central Processing/Communication (All versions < V5.30), CPCX26 Central Processing/Communication (All versions < V06.02), ETA4 Ethernet Interface IEC60870-5-104 (All versions < V10.46), ETA5 Ethernet Int. 1x100TX IEC61850 Ed.2 (All versions < V03.27), PCCX26 Ax 1703 PE, Contr, Communication Element (All versions < V06.05). The affected devices contain an improper null termination vulnerability while parsing a specific HTTP header. This could allow an attacker to execute code in the context of the current process or lead to denial of service condition.
CVE-2023-50763 1 Siemens 8 Simatic Cp 1542sp-1, Simatic Cp 1542sp-1 Irc, Simatic Cp 1543sp-1 and 5 more 2026-04-15 4.9 Medium
A vulnerability has been identified in SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.4.8). The web server of affected products, if configured to allow the import of PKCS12 containers, could end up in an infinite loop when processing incomplete certificate chains. This could allow an authenticated remote attacker to create a denial of service condition by importing specially crafted PKCS12 containers.
CVE-2024-31485 1 Siemens 2 Cpci85 Firmware, Sicore Base System 2026-04-15 7.2 High
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V5.30), SICORE Base system (All versions < V1.3.0). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
CVE-2024-30208 1 Siemens 1 Simatic Rtls Locating Manager 2026-04-15 6.3 Medium
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). The "DBTest" tool of SIMATIC RTLS Locating Manager does not properly enforce access restriction. This could allow an authenticated local attacker to extract sensitive information from memory.
CVE-2024-52504 1 Siemens 1 Siprotec 4 2026-04-15 7.5 High
A vulnerability has been identified in SIPROTEC 4 6MD61 (All versions), SIPROTEC 4 6MD63 (All versions), SIPROTEC 4 6MD66 (All versions), SIPROTEC 4 6MD665 (All versions), SIPROTEC 4 7SA522 (All versions), SIPROTEC 4 7SA6 (All versions < V4.78), SIPROTEC 4 7SD5 (All versions < V4.78), SIPROTEC 4 7SD610 (All versions < V4.78), SIPROTEC 4 7SJ61 (All versions), SIPROTEC 4 7SJ62 (All versions), SIPROTEC 4 7SJ63 (All versions), SIPROTEC 4 7SJ64 (All versions), SIPROTEC 4 7SJ66 (All versions), SIPROTEC 4 7SS52 (All versions), SIPROTEC 4 7ST6 (All versions), SIPROTEC 4 7UM61 (All versions), SIPROTEC 4 7UM62 (All versions), SIPROTEC 4 7UT612 (All versions), SIPROTEC 4 7UT613 (All versions), SIPROTEC 4 7UT63 (All versions), SIPROTEC 4 7VE6 (All versions), SIPROTEC 4 7VK61 (All versions), SIPROTEC 4 7VU683 (All versions), SIPROTEC 4 Compact 7RW80 (All versions), SIPROTEC 4 Compact 7SD80 (All versions), SIPROTEC 4 Compact 7SJ80 (All versions), SIPROTEC 4 Compact 7SJ81 (All versions), SIPROTEC 4 Compact 7SK80 (All versions), SIPROTEC 4 Compact 7SK81 (All versions). Affected devices do not properly handle interrupted operations of file transfer. This could allow an unauthenticated remote attacker to cause a denial of service condition. To restore normal operations, the devices need to be restarted.
CVE-2025-40743 1 Siemens 4 Sinumerik 828d, Sinumerik 840d Sl, Sinumerik Mc and 1 more 2026-04-15 8.3 High
A vulnerability has been identified in SINUMERIK 828D PPU.4 (All versions < V4.95 SP5), SINUMERIK 828D PPU.5 (All versions < V5.25 SP1), SINUMERIK 840D sl (All versions < V4.95 SP5), SINUMERIK MC (All versions < V1.25 SP1), SINUMERIK MC V1.15 (All versions < V1.15 SP5), SINUMERIK ONE (All versions < V6.25 SP1), SINUMERIK ONE V6.15 (All versions < V6.15 SP5). The affected application improperly validates authentication for its VNC access service, allowing access with insufficient password verification. This could allow an attacker to gain unauthorized remote access and potentially compromise system confidentiality, integrity, or availability.