| Arris DG860A, TG862A, and TG862G devices with firmware TS0703128_100611 through TS0705125D_031115 have predictable technician passwords, which makes it easier for remote attackers to obtain access via the web management interface, related to a "password of the day" issue. |
| GE Healthcare Optima CT680, CT540, CT640, and CT520 has a default password of #bigguy for the root user, which has unspecified impact and attack vectors. |
| The HIPAA configuration interface in GE Healthcare Optima MR360 has a password of (1) operator for the root account, (2) adw2.0 for the admin account, and (3) adw2.0 for the sdc account, which has unspecified impact and attack vectors. NOTE: it is not clear whether these passwords are default, hardcoded, or dependent on another system or product that requires a fixed value. |
| GE Healthcare Optima MR360 does not require authentication for the HIPAA emergency login procedure, which allows physically proximate users to gain access via an arbitrary username in the Emergency Login screen. NOTE: this might not qualify for inclusion in CVE if unauthenticated emergency access is part of the intended security policy of the product, can be controlled by the system administrator, and is not enabled by default. |
| GE Healthcare CADStream Server has a default password of confirma for the admin user, which has unspecified impact and attack vectors. |
| The Acquisition Workstation for the GE Healthcare Revolution XQ/i has a password of adw3.1 for the sdc user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value. |
| The password-reset feature in as/index.php in SweetRice CMS before 0.6.7.1 allows remote attackers to modify the administrator's password by specifying the administrator's e-mail address in the email parameter. |
| GE Healthcare Centricity Analytics Server 1.1 has a default password of (1) V0yag3r for the SQL Server sa user, (2) G3car3s for the analyst user, (3) G3car3s for the ccg user, (4) V0yag3r for the viewer user, and (5) geservice for the geservice user in the Webmin interface, which has unspecified impact and attack vectors. |
| GE Healthcare Centricity PACS-IW 3.7.3.7, 3.7.3.8, and possibly other versions has a password of A11enda1e for the sa SQL server user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value. |
| The TeraRecon server, as used in GE Healthcare Centricity PACS-IW 3.7.3.7, 3.7.3.8, and possibly other versions, has a password of (1) shared for the shared user and (2) scan for the scan user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value. |
| GE Healthcare Precision MPi has a password of (1) orion for the serviceapp user, (2) orion for the clinical operator user, and (3) PlatinumOne for the administrator user, which has unspecified impact and attack vectors. NOTE: it is not clear whether these passwords are default, hardcoded, or dependent on another system or product that requires a fixed value. |
| GE Healthcare Centricity PACS 4.0 Server has a default password of (1) nasro for the nasro (ReadOnly) user and (2) nasrw for the nasrw (Read/Write) user, which has unspecified impact and attack vectors. |
| GE Healthcare Centricity PACS Workstation 4.0 and 4.0.1, and Server 4.0, has a password of 2charGE for the geservice account, which has unspecified impact and attack vectors related to TimbuktuPro. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires it. |
| EMC PowerPath Virtual Appliance (aka vApp) before 2.0 has default passwords for the (1) emcupdate and (2) svcuser accounts, which makes it easier for remote attackers to obtain potentially sensitive information via a login session. |
| Ceragon FibeAir IP-10 bridges have a default password for the root account, which makes it easier for remote attackers to obtain access via a (1) HTTP, (2) SSH, (3) TELNET, or (4) CLI session. |
| The web interface on SerVision HVG Video Gateway devices with firmware before 2.2.26a100 has a hardcoded administrative password, which makes it easier for remote attackers to obtain access via an HTTP session. |
| Pearson ProctorCache before 2015.1.17 uses the same hardcoded password across different customers' installations, which allows remote attackers to modify test metadata or cause a denial of service (test disruption) by leveraging knowledge of this password. |
| Inductive Automation Ignition 7.7.2 uses MD5 password hashes, which makes it easier for context-dependent attackers to obtain access via a brute-force attack. |
| Fortinet FortiAuthenticator 3.0.0 has a password of (1) slony for the slony PostgreSQL user and (2) www-data for the www-data PostgreSQL user, which makes it easier for remote attackers to obtain access via unspecified vectors. |
| The puppet manifests in the Red Hat openstack-puppet-modules package before 2014.2.13-2 uses a default password of CHANGEME for the pcsd daemon, which allows remote attackers to execute arbitrary shell commands via unspecified vectors. |