| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Automotive Shop Management System v1.0 is vulnerable to SQL Injection via /asms/classes/Master.php?f=delete_product. |
| Water-billing-management-system v1.0 is affected by: Cross Site Scripting (XSS) via /wbms/classes/Users.php?f=save, firstname. |
| Water-billing-management-system v1.0 is vulnerable to SQL Injection via /wbms/classes/Master.php?f=delete_client, id |
| Simple Social Networking Site v1.0 is vulnerable to Cross Site Scripting (XSS) via /sns/classes/Users.php?f=save, firstname. |
| ChatBot App with Suggestion in PHP/OOP v1.0 is vulnerable to SQL Injection via /simple_chat_bot/classes/Master.php?f=delete_response, id. |
| Automotive Shop Management System v1.0 is vulnerable to Cross Site Scripting (XSS) via /asms/classes/Master.php?f=save_product, name. |
| Badminton Center Management System 1.0 is vulnerable to Cross Site Scripting (XSS) via /bcms/classes/Master.php?f=save_court_rental. |
| Badminton Center Management System 1.0 is vulnerable to SQL Injection via /bcms/classes/Master.php?f=delete_court_rental, id. |
| Merchandise Online Store 1.0 is vulnerable to SQL Injection via /vloggers_merch/classes/Master.php?f=delete_product. |
| Tenda Technology Co.,Ltd HG6 3.3.0-210926 was discovered to contain a command injection vulnerability via the pingAddr and traceAddr parameters. This vulnerability is exploited via a crafted POST request. |
| An issue was found on TRENDnet TEW-831DR 1.0 601.130.1.1356 devices. An OS injection vulnerability exists within the web interface, allowing an attacker with valid credentials to execute arbitrary shell commands. |
| An issue was found on TRENDnet TEW-831DR 1.0 601.130.1.1356 devices. The username and password setup for the web interface does not require entering the existing password. A malicious user can change the username and password of the interface. |
| An issue was found on TRENDnet TEW-831DR 1.0 601.130.1.1356 devices. The web interface is vulnerable to CSRF. An attacker can change the pre-shared key of the Wi-Fi router if the interface's IP address is known. |
| An issue was found on TRENDnet TEW-831DR 1.0 601.130.1.1356 devices. The network pre-shared key field on the web interface is vulnerable to XSS. An attacker can use a simple XSS payload to crash the basic.config page of the web interface. |
| An issue was found on TRENDnet TEW-831DR 1.0 601.130.1.1356 devices. The default pre-shared key for the Wi-Fi networks is the same for every router except for the last four digits. The device default pre-shared key for both 2.4 GHz and 5 GHz networks can be guessed or brute-forced by an attacker within range of the Wi-Fi network. |
| Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. According to FSCT-2022-0056, there is a Honeywell ControlEdge hardcoded credentials issue. The affected components are characterized as: SSH. The potential impact is: Remote code execution, manipulate configuration, denial of service. The Honeywell ControlEdge PLC and RTU product line exposes an SSH service on port 22/TCP. Login as root to this service is permitted and credentials for the root user are hardcoded without automatically changing them upon first commissioning. The credentials for the SSH service are hardcoded in the firmware. The credentials grant an attacker access to a root shell on the PLC/RTU, allowing for remote code execution, configuration manipulation and denial of service. |
| Honeywell Experion LX through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0055, there is a Honeywell Experion LX Control Data Access (CDA) EpicMo protocol with unauthenticated functionality issue. The affected components are characterized as: Honeywell Control Data Access (CDA) EpicMo (55565/TCP). The potential impact is: Firmware manipulation, Denial of service. The Honeywell Experion LX Distributed Control System (DCS) utilizes the Control Data Access (CDA) EpicMo protocol (55565/TCP) for device diagnostics and maintenance purposes. This protocol does not have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. There is no authentication functionality on the protocol in question. An attacker capable of invoking the protocols' functionalities could issue firmware download commands potentially allowing for firmware manipulation and reboot devices causing denial of service. |
| In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-refresh-request" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection. |
| In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-acknerr-request" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection. |
| In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-web-viewer-request-off" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection. |