| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| INIM Electronics Smartliving SmartLAN/G/SI <=6.x contains hard-coded credentials in its Linux distribution image that cannot be changed through normal device operations. Attackers can exploit these persistent credentials to log in and gain unauthorized system access across multiple SmartLiving device models. |
| A vulnerability classified as critical was found in IROAD Dash Cam X5 and Dash Cam X6 up to 20250308. Affected by this vulnerability is an unknown functionality of the component Device Pairing. The manipulation leads to hard-coded credentials. Access to the local network is required for this attack to succeed. The complexity of an attack is rather high. The exploitation appears to be difficult. The vendor was contacted early about this disclosure but did not respond in any way. |
| Project AI is a platform designed to create AI agents. Prior to the pre-beta version, a hardcoded API key was present in the source code. This issue has been patched in the pre-beta version. |
| Ubiquiti U7-Pro 7.0.35 was discovered to contain a hardcoded password vulnerability in /etc/shadow, which allows attackers to log in as root. NOTE: this is disputed by the Supplier because the observation only established that a password is present in a firmware image; however, the device cannot be deployed without setting a new password during installation. |
| ui/pref/ProxyPrefView.java in weasis-core in Weasis 4.5.1 has a hardcoded key for symmetric encryption of proxy credentials. |
| Ubiquiti U6-LR 6.6.65 was discovered to contain a hardcoded password vulnerability in /etc/shadow, which allows attackers to log in as root. NOTE: In Ubiquiti's view there is no vulnerability as the Hardcoded Password should be after setup not before. |
| A hardcoded decryption key in Thinkware Cloud APK v4.3.46 allows attackers to access sensitive data and execute arbitrary commands with elevated privileges. |
| Ever Traduora 0.20.0 and below is vulnerable to Privilege Escalation due to the use of a hard-coded JWT signing key. |
| Neye3C v4.5.2.0 was discovered to contain a hardcoded encryption key in the firmware update mechanism. |
| A vulnerability was discovered in the storage policy for certain sets of encryption keys in the HPE Telco Network Function Virtual Orchestrator. Successful Exploitation could lead to unauthorized parties gaining access to sensitive system information. |
| NVIDIA AIStore contains a vulnerability in AuthN. A successful exploit of this vulnerability might lead to escalation of privileges, information disclosure, and data tampering. |
| Use of Hard-coded Credentials vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5 and newer versions |
| hippo4j 1.0.0 to 1.5.0, uses a hard-coded secret key in its JWT (JSON Web Token) creation. This allows attackers with access to the source code or compiled binary to forge valid access tokens and impersonate any user, including privileged ones such as "admin". The vulnerability poses a critical security risk in systems where authentication and authorization rely on the integrity of JWTs. |
| The firmware of all Wattsense Bridge devices contain the same hard-coded user and root credentials. The user password can be easily recovered via password cracking attempts. The recovered credentials can be used to log into the device via the login shell that is exposed by the serial interface. The backdoor user has been removed in firmware BSP >= 6.4.1. |
| Infoblox BloxOne v2.4 was discovered to contain a business logic flaw due to thick client vulnerabilities. |
| FLIR Thermal Camera F/FC/PT/D firmware version 8.0.0.64 contains hard-coded SSH credentials that cannot be changed through normal camera operations. Attackers can leverage these persistent, unmodifiable credentials to gain unauthorized remote access to the thermal camera system. |
| A vulnerability exists in multiple Radiometer products that allow an attacker with physical access to the analyzer possibility to extract credential information. The vulnerability is due to a weakness in the design and insufficient credential protection in operating system.
Other related CVE's are CVE-2025-14095 & CVE-2025-14097.
Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency.
Required Configuration for Exposure:
Attacker requires physical access to the analyzer.
Temporary work Around:
Only authorized people can physically access the analyzer.
Permanent solution:
Local Radiometer representatives will contact all affected customers to discuss a permanent solution.
Exploit Status:
Researchers have provided a working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication. |
| An issue in H3C Magic M Device M2V100R006 allows a remote attacker to execute arbitrary code via the default password |
| An issue in H3C Device R365V300R004 allows a remote attacker to execute arbitrary code via the default password. NOTE: the Supplier's position is that their "product lines enforce or clearly prompt users to change any initial credentials upon first use. At most, this would be a case of misconfiguration if an administrator deliberately ignored the prompts, which is outside the scope of CVE definitions." |
| The program libraries (DLL) and binaries used by exos 9300 contain multiple hard-coded secrets. One notable example is the function "EncryptAndDecrypt" in the library Kaba.EXOS.common.dll. This algorithm uses a simple XOR encryption technique combined with a cryptographic key (cryptoKey) to transform each character of the input string. However, it's important to note that this implementation does not provide strong encryption and should not be considered secure for sensitive data. It's more of a custom encryption approach rather than a common algorithm used in cryptographic applications. The key itself is static and based on the founder's name of the company. The functionality is for example used to encrypt the user PINs before storing them in the MSSQL database. |