| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability was found in SGAI Space1 NAS N1211DS up to 1.0.915. This issue affects the function GET_FACTORY_INFO/GET_USER_INFO of the file /cgi-bin/JSONAPI of the component gsaiagent. The manipulation results in unprotected storage of credentials. The attack can be launched remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Argo Workflows Chart is used to set up argo and its needed dependencies through one command. Prior to 0.44.0, the workflow-role has excessive privileges, the worst being create pods/exec, which will allow kubectl exec into any Pod in the same namespace, i.e. arbitrary code execution within those Pods. If a user can be made to run a malicious template, their whole namespace can be compromised. This affects versions of the argo-workflows Chart that use appVersion: 3.4 and above, which no longer need these permissions for the only available Executor, Emissary. It could also affect users below 3.4 depending on their choice of Executor in those versions. This only affects the Helm Chart and not the upstream manifests. This vulnerability is fixed in 0.44.0. |
| An issue was discovered in Grandstream GXP14XX 1.0.8.9 and GXP16XX 1.0.7.13, allows remote attackers to escalate privileges via incorrect access control using an end-user session-identity token. |
| A vulnerability has been found in E-Lins H685, H685f, H700, H720, H750, H820, H820Q, H820Q0 and H900 up to 3.2 and classified as critical. This vulnerability affects unknown code of the component OEM Backend. The manipulation leads to hard-coded credentials. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. It is recommended to change the configuration settings. The vendor was contacted early about this disclosure but did not respond in any way. |
| SAP GUI for Windows allows an unauthenticated attacker to exploit insecure obfuscation algorithms used by the GuiXT application to store user credentials. While this issue does not impact the Integrity or Availability of the application, it may have a Low impact on the Confidentiality of data. |
| Attackers with local access to the medical office computer can
escalate their Windows user privileges to "NT AUTHORITY\SYSTEM" by
overwriting one of two Elefant service binaries with weak permissions. The default installation directory of Elefant is "C:\Elefant1" which is
writable for all users. In addition, the Elefant installer registers two
Firebird database services which are running as “NT AUTHORITY\SYSTEM”.
Path: C:\Elefant1\Firebird_2\bin\fbserver.exe
Path: C:\Elefant1\Firebird_2\bin\fbguard.exe
Both service binaries are user writable. This means that a local
attacker can rename one of the service binaries, replace the service
executable with a new executable, and then restart the system. Once the
system has rebooted, the new service binary is executed as "NT
AUTHORITY\SYSTEM". |
| A vulnerability classified as problematic has been found in Audi Universal Traffic Recorder App 2.0. Affected is an unknown function of the component FTP Credentials. The manipulation leads to use of hard-coded password. Attacking locally is a requirement. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. Upgrading to version 2.89 and 2.90 is able to address this issue. It is recommended to upgrade the affected component. The vendor was contacted early about these issues and acted very professional. Version 2.89 is fixing this issue for new customers and 2.90 is going to fix it for existing customers. |
| A vulnerability classified as problematic was found in Audi UTR Dashcam 2.0. Affected by this vulnerability is an unknown functionality of the component Video Stream Handler. The manipulation leads to hard-coded credentials. The attack can only be initiated within the local network. The exploit has been disclosed to the public and may be used. Upgrading to version 2.89 and 2.90 is able to address this issue. It is recommended to upgrade the affected component. The vendor was contacted early about these issues and acted very professional. Version 2.89 is fixing this issue for new customers and 2.90 is going to fix it for existing customers. |
| NVIDIA GPU Display Driver for Windows contains a vulnerability in the kernel mode layer when the driver is performing an operation at a privilege level that is higher than the minimum level required. A successful exploit of this vulnerability may lead to code execution, denial of service, escalation of privileges, information disclosure, and data tampering. |
| A vulnerability in the Incoming Goods Suite allows a user with unprivileged access to the underlying system (e.g. local or via SSH) a privilege escalation to the administrative level due to the usage of component vendor Docker images running with root permissions. Exploiting this misconfiguration leads to the fact that an attacker can gain administrative control. over the whole system. |
| Medtronic MyCareLink Patient Monitor has a built-in user account with an empty password, which allows an attacker with physical access to log in with no password and access modify system functionality.
This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025 |
| In BootRom, there is a possible unchecked write address. This could lead to local escalation of privilege with no additional execution privileges needed. |
| In BootRom, there's a possible unchecked command index. This could lead to local escalation of privilege with no additional execution privileges needed. |
| A vulnerability has been found in TOZED ZLT M30S and ZLT M30S PRO 1.47/3.09.06. Affected is an unknown function of the component Web Interface. Such manipulation leads to hard-coded credentials. The attack needs to be initiated within the local network. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A Plaintext Storage of a Password vulnerability in SUSE exposes the credentials for the HTTP proxy in the log files. This issue affects Container suse/manager/4.3/proxy-httpd:4.3.16.9.67.1: from ? before 4.3.33-150400.3.55.2; Container suse/manager/5.0/x86_64/proxy-httpd:5.0.5.7.23.1: from ? before 5.0.14-150600.4.17.1; Container suse/manager/5.0/x86_64/server:5.0.5.7.30.1: from ? before 5.0.14-150600.4.17.1; Image SLES15-SP4-Manager-Proxy-4-3-BYOS: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Proxy-4-3-BYOS-Azure: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Proxy-4-3-BYOS-EC2: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Proxy-4-3-BYOS-GCE: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-Azure: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-EC2: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-GCE: from ? before 4.3.33-150400.3.55.2; SUSE Manager Proxy Module 4.3: from ? before 4.3.33-150400.3.55.2; SUSE Manager Server Module 4.3: from ? before 4.3.33-150400.3.55.2. |
| WF2220 exposes endpoint /cgi-bin-igd/netcore_get.cgi that returns configuration of the device to unauthorized users. Returned configuration includes cleartext password.
The vendor was contacted early about this disclosure but did not respond in any way. |
| The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS. |
| The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS. |
| The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS. |
| On affected platforms running Arista EOS with a gNMI transport enabled, running the gNOI File TransferToRemote RPC with credentials for a remote server may cause these remote-server credentials to be logged or accounted on the local EOS device or possibly on other remote accounting servers (i.e. TACACS, RADIUS, etc). |