| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| GE UR firmware versions prior to version 8.1x web server interface is supported on UR over HTTP protocol. It allows sensitive information exposure without authentication. |
| GE Gas Power ToolBoxST Version v04.07.05C suffers from an XML external entity (XXE) vulnerability using the DTD parameter entities technique that could result in disclosure and retrieval of arbitrary data on the affected node via an out-of-band (OOB) attack. The vulnerability is triggered when input passed to the XML parser is not sanitized while parsing the XML project/template file. |
| Delta Electronics DIAEnergie (Version 1.7.5 and prior) is vulnerable to cleartext transmission as the web application runs by default on HTTP. This could allow an attacker to remotely read transmitted information between the client and product. |
| A getfile function in MDT AutoSave versions prior to v6.02.06 enables a user to supply an optional parameter, resulting in the processing of a request in a special manner. This can result in the execution of an unzip command and place a malicious .exe file in one of the locations the function looks for and get execution capabilities. |
| An attacker can gain knowledge of a session temporary working folder where the getfile and putfile commands are used in MDT AutoSave versions prior to v6.02.06. An attacker can leverage this knowledge to provide a malicious command to the working directory where the read and write activity can be initiated. |
| A function in MDT AutoSave versions prior to v6.02.06 is used to retrieve system information for a specific process, and this information collection executes multiple commands and summarizes the information into an XML. This function and subsequent process gives full path to the executable and is therefore vulnerable to binary hijacking. |
| An attacker could utilize a function in MDT AutoSave versions prior to v6.02.06 that permits changing a designated path to another path and traversing the directory, allowing the replacement of an existing file with a malicious file. |
| An attacker could decipher the encryption and gain access to MDT AutoSave versions prior to v6.02.06. |
| Two buffer overflows in the built-in web server in Moxa NPort IAW5000A-I/O Series firmware version 2.2 or earlier may allow a remote attacker to cause a denial-of-service condition. |
| Data can be copied without validation in the built-in web server in Moxa NPort IAW5000A-I/O series firmware version 2.2 or earlier, which may allow a remote attacker to cause denial-of-service conditions. |
| Philips Vue PACS versions 12.2.x.x and prior uses a cryptographic key or password past its expiration date, which diminishes its safety significantly by increasing the timing window for cracking attacks against that key. |
| Philips Vue PACS versions 12.2.x.x and prior transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. |
| An exception is thrown from a function in AVEVA System Platform versions 2017 through 2020 R2 P01, but it is not caught, which may cause a denial-of-service condition. |
| The programming protocol allows for a previously entered password and lock state to be read by an attacker. If the previously entered password was successful, the attacker can then use the password to unlock Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00. |
| Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 passwords are sent as plaintext during unlocking and project transfers. An attacker who has network visibility can observe the password exchange. |
| Softing OPC UA C++ SDK (Software Development Kit) versions from 5.59 to 5.64 exported library functions don't properly validate received extension objects, which may allow an attacker to crash the software by sending a variety of specially crafted packets to access several unexpected memory locations. |
| A specially crafted packet sent to the Fernhill SCADA Server Version 3.77 and earlier may cause an exception, causing the server process (FHSvrService.exe) to exit. |
| A relative path traversal attack in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers with service user privileges to upload arbitrary files. By uploading a specially crafted tar file an attacker can execute arbitrary commands. |
| A reflected cross-site scripting (XSS) vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows remote attackers to inject arbitrary web script or HTML into various locations. |
| A XPath injection vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows unauthenticated remote attackers to access sensitive information and escalate privileges. |