Search Results (4869 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-32353 2026-04-15 8.2 High
Kaseya Rapid Fire Tools Network Detective 2.0.16.0 has Unencrypted Credentials (for privileged access) stored in the collector.txt configuration file.
CVE-2025-22493 2026-04-15 5.6 Medium
Secure flag not set and SameSIte was set to Lax in the Foreseer Reporting Software (FRS). Absence of this secure flag could lead into the session cookie being transmitted over unencrypted HTTP connections. This security issue has been resolved in the latest version of FRS v1.5.100.
CVE-2025-36751 1 Growatt 2 Mic3300tl-x, Shinelan-x 2026-04-15 N/A
Encryption is missing on the configuration interface for Growatt ShineLan-X and MIC 3300TL-X. This allows an attacker with access to the network to intercept and potentially manipulate communication requests between the inverter and its cloud endpoint.
CVE-2024-27166 1 Toshibatec 50 E-studio-2010-ac, E-studio-2015-nc, E-studio-2018 A and 47 more 2026-04-15 7.4 High
Coredump binaries in Toshiba printers have incorrect permissions. A local attacker can steal confidential information. As for the affected products/models/versions, see the reference URL.
CVE-2025-41647 2026-04-15 5.5 Medium
A local, low-privileged attacker can learn the password of the connected controller in PLC Designer V4 due to an incorrect implementation that results in the password being displayed in plain text under special conditions.
CVE-2024-3742 2026-04-15 7.5 High
Electrolink transmitters store credentials in clear-text. Use of these credentials could allow an attacker to access the system.
CVE-2024-28169 2026-04-15 5.4 Medium
Cleartext transmission of sensitive information for some BigDL software maintained by Intel(R) before version 2.5.0 may allow an authenticated user to potentially enable denial of service via adjacent access.
CVE-2025-10540 1 Imonitor 1 Imonitor Eam 2026-04-15 6.5 Medium
iMonitor EAM 9.6394 transmits communication between the EAM client agent and the EAM server, as well as between the EAM monitor management software and the server, in plaintext without authentication or encryption. An attacker with network access can intercept sensitive information (such as credentials, keylogger data, and personally identifiable information) and tamper with traffic. This allows both unauthorized disclosure and modification of data, including issuing arbitrary commands to client agents.
CVE-2025-56447 1 Tm2 1 Monitoring 2026-04-15 9.8 Critical
TM2 Monitoring v3.04 contains an authentication bypass and plaintext credential disclosure.
CVE-2025-8863 1 Yugabyte 1 Yugabytedb 2026-04-15 3.7 Low
YugabyteDB diagnostic information was transmitted over HTTP, which could expose sensitive data during transmission
CVE-2025-62765 1 General Industrial Controls 1 Lynx+ Gateway 2026-04-15 7.5 High
General Industrial Controls Lynx+ Gateway is vulnerable to a cleartext transmission vulnerability that could allow an attacker to observe network traffic to obtain sensitive information, including plaintext credentials.
CVE-2024-28327 1 Asus 1 Rt-n12\+ B1 2026-04-15 8.4 High
Asus RT-N12+ B1 router stores user passwords in plaintext, which could allow local attackers to obtain unauthorized access and modify router settings.
CVE-2024-23942 2026-04-15 7.1 High
A local user may find a configuration file on the client workstation with unencrypted sensitive data. This allows an attacker to impersonate the device or prevent the device from accessing the cloud portal which leads to a DoS.
CVE-2024-33471 2026-04-15 7.2 High
An issue in the Sensor Settings of AVTECH Room Alert 4E v4.4.0 allows attackers to gain access to SMTP credentials in plaintext via a crafted AJAX request. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.
CVE-2025-2818 2026-04-15 3.5 Low
A vulnerability was reported in version 1.0 of the Bluetooth Transmission Alliance protocol adopted by Motorola Smart Connect Android Application that could allow a nearby attacker within the Bluetooth interaction range to intercept files when transferred to a device not paired in Smart Connect.
CVE-2025-7426 1 Minova 1 Tta 2026-04-15 N/A
Information disclosure and exposure of authentication FTP credentials over the debug port 1604 in the MINOVA TTA service. This allows unauthenticated remote access to an active FTP account containing sensitive internal data and import structures. In environments where this FTP server is part of automated business processes (e.g. EDI or data integration), this could lead to data manipulation, extraction, or abuse.  Debug ports 1602, 1603 and 1636 also expose service architecture information and system activity logs
CVE-2023-28912 2026-04-15 5.7 Medium
The MIB3 unit stores the synchronized phone contact book in clear-text, allowing an attacker with either code execution privilege on the system or physical access to the system to obtain vehicle owner's contact data. The vulnerability was originally discovered in Skoda Superb III car with MIB3 infotainment unit OEM part number 3V0035820. The list of affected MIB3 OEM part numbers is provided in the referenced resources.
CVE-2025-52579 2026-04-15 9.4 Critical
Emerson ValveLink Products store sensitive information in cleartext in memory. The sensitive memory might be saved to disk, stored in a core dump, or remain uncleared if the product crashes, or if the programmer does not properly clear the memory before freeing it.
CVE-2025-52351 2026-04-15 8.8 High
Aikaan IoT management platform v3.25.0325-5-g2e9c59796 sends a newly generated password to users in plaintext via email and also includes the same password as a query parameter in the account activation URL (e.g., https://domain.com/activate=xyz). This practice can result in password exposure via browser history, proxy logs, referrer headers, and email caching. The vulnerability impacts user credential confidentiality during initial onboarding.
CVE-2024-38283 1 Motorolasolutions 1 Vigilant Fixed Lpr Coms Box Bcav1f2 C600 2026-04-15 N/A
Sensitive customer information is stored in the device without encryption.