| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| AVEVA System Platform versions 2017 through 2020 R2 P01 uses external input to construct a pathname that is intended to identify a file or directory that is located underneath a restricted parent directory, but the software does not properly neutralize special elements within the pathname that can cause the pathname to resolve to a location that is outside of the restricted directory. |
| AVEVA System Platform versions 2017 through 2020 R2 P01 does not perform any authentication for functionality that requires a provable user identity. |
| Connected Components Workbench (v13.00.00 and prior), ISaGRAF Workbench (v6.0 though v6.6.9), and Safety Instrumented System Workstation (v1.2 and prior (for Trusted Controllers)) do not limit the objects that can be deserialized. This allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in arbitrary code execution. This vulnerability requires user interaction to be successfully exploited |
| The affected On-Premise cnMaestro is vulnerable to a pre-auth data exfiltration through improper neutralization of special elements used in an SQL command. This could allow an attacker to exfiltrate data about other user’s accounts and devices. |
| The affected Bachmann Electronic M-Base Controllers of version MSYS v1.06.14 and later use weak cryptography to protect device passwords. Affected controllers that are actively supported include MX207, MX213, MX220, MC206, MC212, MC220, and MH230 hardware controllers, and affected end-of-life controller include MC205, MC210, MH212, ME203, CS200, MP213, MP226, MPC240, MPC265, MPC270, MPC293, MPE270, and CPC210 hardware controllers. Security Level 0 is set at default from the manufacturer, which could allow an unauthenticated remote attacker to gain access to the password hashes. Security Level 4 is susceptible if an authenticated remote attacker or an unauthenticated person with physical access to the device reads and decrypts the password to conduct further attacks. |
| Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed. |
| When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) (disregarding Axeda agent v6.9.2 and v6.9.3) is vulnerable to directory traversal, which could allow a remote unauthenticated attacker to obtain file system read access via web server.. |
| When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send a certain command to a specific port without authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to shut down a specific service. |
| When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) when receiving certain input throws an exception. Services using said function do not handle the exception. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to crash the affected product. |
| An exception is thrown from a function in AVEVA System Platform versions 2017 through 2020 R2 P01, but it is not caught, which may cause a denial-of-service condition. |
| The programming protocol allows for a previously entered password and lock state to be read by an attacker. If the previously entered password was successful, the attacker can then use the password to unlock Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00. |
| Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 passwords are sent as plaintext during unlocking and project transfers. An attacker who has network visibility can observe the password exchange. |
| Softing OPC UA C++ SDK (Software Development Kit) versions from 5.59 to 5.64 exported library functions don't properly validate received extension objects, which may allow an attacker to crash the software by sending a variety of specially crafted packets to access several unexpected memory locations. |
| The affected On-Premise cnMaestro is vulnerable to execution of code on the cnMaestro hosting server. This could allow a remote attacker to change server configuration settings. |
| Inkscape version 0.91 is vulnerable to an out-of-bounds write, which may allow an attacker to arbitrary execute code. |
| Due to an XML external entity reference, the software parses XML in the backup/restore functionality without XML security flags, which may lead to a XXE attack while restoring the backup. |
| File Upload vulnerability in PluckCMS v.4.7.10 allows a remote attacker to execute arbitrary code via the trashcan_restoreitem.php file. |
| SourceCodester Computer Laboratory Management System 1.0 is vulnerable to Incorrect Access Control. via /php-lms/admin/?page=user/list. |
| An XML External Entity (XXE) vulnerability in Elspec Engineering G5 Digital Fault Recorder Firmware v1.2.1.12 allows attackers to cause a Denial of Service (DoS) via a crafted XML payload. |
| An issue was discovered in Elspec G5 digital fault recorder version 1.2.1.12 and earlier. An XML External Entity (XXE) vulnerability may allow an attacker to cause a Denial of Service (DoS) via a crafted XML payload. |