Search

Search Results (358816 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-26263 2026-04-15 5.1 Medium
GeoVision ASManager Windows desktop application with the version 6.1.2.0 or less (fixed in 6.2.0), is vulnerable to credentials disclosure due to improper memory handling in the ASManagerService.exe process.
CVE-2025-26278 2026-04-15 7.5 High
A prototype pollution in the lib.set function of dref v0.1.2 allows attackers to cause a Denial of Service (DoS) via supplying a crafted payload.
CVE-2025-26318 2026-04-15 5.8 Medium
hb.exe in TSplus Remote Access before 17.30 2024-10-30 allows remote attackers to retrieve a list of all domain accounts currently connected to the application.
CVE-2025-26326 2026-04-15 8.8 High
A vulnerability was identified in the NVDA Remote (version 2.6.4) and Tele NVDA Remote (version 2025.3.3) remote connection add-ons, which allows an attacker to obtain total control of the remote system by guessing a weak password. The problem occurs because these add-ons accept any password entered by the user and do not have an additional authentication or computer verification mechanism. Tests indicate that more than 1,000 systems use easy-to-guess passwords, many with less than 4 to 6 characters, including common sequences. This allows brute force attacks or trial-and-error attempts by malicious invaders. The vulnerability can be exploited by a remote attacker who knows or can guess the password used in the connection. As a result, the attacker gains complete access to the affected system and can execute commands, modify files, and compromise user security.
CVE-2023-54148 1 Linux 1 Linux Kernel 2026-04-15 7.0 High
In the Linux kernel, the following vulnerability has been resolved: net/mlx5e: Move representor neigh cleanup to profile cleanup_tx For IP tunnel encapsulation in ECMP (Equal-Cost Multipath) mode, as the flow is duplicated to the peer eswitch, the related neighbour information on the peer uplink representor is created as well. In the cited commit, eswitch devcom unpair is moved to uplink unload API, specifically the profile->cleanup_tx. If there is a encap rule offloaded in ECMP mode, when one eswitch does unpair (because of unloading the driver, for instance), and the peer rule from the peer eswitch is going to be deleted, the use-after-free error is triggered while accessing neigh info, as it is already cleaned up in uplink's profile->disable, which is before its profile->cleanup_tx. To fix this issue, move the neigh cleanup to profile's cleanup_tx callback, and after mlx5e_cleanup_uplink_rep_tx is called. The neigh init is moved to init_tx for symmeter. [ 2453.376299] BUG: KASAN: slab-use-after-free in mlx5e_rep_neigh_entry_release+0x109/0x3a0 [mlx5_core] [ 2453.379125] Read of size 4 at addr ffff888127af9008 by task modprobe/2496 [ 2453.381542] CPU: 7 PID: 2496 Comm: modprobe Tainted: G B 6.4.0-rc7+ #15 [ 2453.383386] Hardware name: QEMU Standard PC (Q35 + ICH9, 2009), BIOS rel-1.13.0-0-gf21b5a4aeb02-prebuilt.qemu.org 04/01/2014 [ 2453.384335] Call Trace: [ 2453.384625] <TASK> [ 2453.384891] dump_stack_lvl+0x33/0x50 [ 2453.385285] print_report+0xc2/0x610 [ 2453.385667] ? __virt_addr_valid+0xb1/0x130 [ 2453.386091] ? mlx5e_rep_neigh_entry_release+0x109/0x3a0 [mlx5_core] [ 2453.386757] kasan_report+0xae/0xe0 [ 2453.387123] ? mlx5e_rep_neigh_entry_release+0x109/0x3a0 [mlx5_core] [ 2453.387798] mlx5e_rep_neigh_entry_release+0x109/0x3a0 [mlx5_core] [ 2453.388465] mlx5e_rep_encap_entry_detach+0xa6/0xe0 [mlx5_core] [ 2453.389111] mlx5e_encap_dealloc+0xa7/0x100 [mlx5_core] [ 2453.389706] mlx5e_tc_tun_encap_dests_unset+0x61/0xb0 [mlx5_core] [ 2453.390361] mlx5_free_flow_attr_actions+0x11e/0x340 [mlx5_core] [ 2453.391015] ? complete_all+0x43/0xd0 [ 2453.391398] ? free_flow_post_acts+0x38/0x120 [mlx5_core] [ 2453.392004] mlx5e_tc_del_fdb_flow+0x4ae/0x690 [mlx5_core] [ 2453.392618] mlx5e_tc_del_fdb_peers_flow+0x308/0x370 [mlx5_core] [ 2453.393276] mlx5e_tc_clean_fdb_peer_flows+0xf5/0x140 [mlx5_core] [ 2453.393925] mlx5_esw_offloads_unpair+0x86/0x540 [mlx5_core] [ 2453.394546] ? mlx5_esw_offloads_set_ns_peer.isra.0+0x180/0x180 [mlx5_core] [ 2453.395268] ? down_write+0xaa/0x100 [ 2453.395652] mlx5_esw_offloads_devcom_event+0x203/0x530 [mlx5_core] [ 2453.396317] mlx5_devcom_send_event+0xbb/0x190 [mlx5_core] [ 2453.396917] mlx5_esw_offloads_devcom_cleanup+0xb0/0xd0 [mlx5_core] [ 2453.397582] mlx5e_tc_esw_cleanup+0x42/0x120 [mlx5_core] [ 2453.398182] mlx5e_rep_tc_cleanup+0x15/0x30 [mlx5_core] [ 2453.398768] mlx5e_cleanup_rep_tx+0x6c/0x80 [mlx5_core] [ 2453.399367] mlx5e_detach_netdev+0xee/0x120 [mlx5_core] [ 2453.399957] mlx5e_netdev_change_profile+0x84/0x170 [mlx5_core] [ 2453.400598] mlx5e_vport_rep_unload+0xe0/0xf0 [mlx5_core] [ 2453.403781] mlx5_eswitch_unregister_vport_reps+0x15e/0x190 [mlx5_core] [ 2453.404479] ? mlx5_eswitch_register_vport_reps+0x200/0x200 [mlx5_core] [ 2453.405170] ? up_write+0x39/0x60 [ 2453.405529] ? kernfs_remove_by_name_ns+0xb7/0xe0 [ 2453.405985] auxiliary_bus_remove+0x2e/0x40 [ 2453.406405] device_release_driver_internal+0x243/0x2d0 [ 2453.406900] ? kobject_put+0x42/0x2d0 [ 2453.407284] bus_remove_device+0x128/0x1d0 [ 2453.407687] device_del+0x240/0x550 [ 2453.408053] ? waiting_for_supplier_show+0xe0/0xe0 [ 2453.408511] ? kobject_put+0xfa/0x2d0 [ 2453.408889] ? __kmem_cache_free+0x14d/0x280 [ 2453.409310] mlx5_rescan_drivers_locked.part.0+0xcd/0x2b0 [mlx5_core] [ 2453.409973] mlx5_unregister_device+0x40/0x50 [mlx5_core] [ 2453.410561] mlx5_uninit_one+0x3d/0x110 [mlx5_core] [ 2453.411111] remove_one+0x89/0x130 [mlx5_core] [ 24 ---truncated---
CVE-2025-26382 2026-04-15 N/A
Under certain circumstances the iSTAR Configuration Utility (ICU) tool could have a buffer overflow issue
CVE-2025-26383 2026-04-15 N/A
The iSTAR Configuration Utility (ICU) tool leaks memory, which could result in the unintended exposure of unauthorized data from the Windows PC that ICU is running on.
CVE-2025-26396 2026-04-15 7.8 High
The SolarWinds Dameware Mini Remote Control was determined to be affected by Incorrect Permissions Local Privilege Escalation Vulnerability. This vulnerability requires local access and a valid low privilege account to be susceptible to this vulnerability.
CVE-2025-26408 2026-04-15 6.1 Medium
The JTAG interface of Wattsense Bridge devices can be accessed with physical access to the PCB. After connecting to the interface, full access to the device is possible. This enables an attacker to extract information, modify and debug the device's firmware. All known versions are affected.
CVE-2025-26401 2026-04-15 N/A
Weak encoding for password vulnerability exists in HMI ViewJet C-more series. If this vulnerability is exploited, authentication information may be obtained by a local authenticated attacker.
CVE-2025-26402 1 Intel 1 Npu Drivers 2026-04-15 6.5 Medium
Protection mechanism failure for some Intel(R) NPU Drivers within Ring 3: User Applications may allow a denial of service. Unprivileged software adversary with an authenticated user combined with a low complexity attack may enable denial of service. This result may potentially occur via local access when attack requirements are not present without special internal knowledge and requires no user interaction. The potential vulnerability may impact the confidentiality (none), integrity (none) and availability (high) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (none) impacts.
CVE-2025-26403 1 Intel 2 Xeon, Xeon Processors 2026-04-15 7.2 High
Out-of-bounds write in the memory subsystem for some Intel(R) Xeon(R) 6 processors when using Intel(R) SGX or Intel(R) TDX may allow a privileged user to potentially enable escalation of privilege via local access.
CVE-2025-26404 1 Intel 1 Dsa Software 2026-04-15 6.7 Medium
Uncontrolled search path for some Intel(R) DSA software before version 25.2.15.9 may allow an authenticated user to potentially enable escalation of privilege via local access.
CVE-2025-26409 2026-04-15 6.8 Medium
A serial interface can be accessed with physical access to the PCB of Wattsense Bridge devices. After connecting to the interface, access to the bootloader is possible, as well as a Linux login prompt. The bootloader access can be used to gain a root shell on the device. This issue is fixed in recent firmware versions BSP >= 6.4.1.
CVE-2025-26410 2026-04-15 9.8 Critical
The firmware of all Wattsense Bridge devices contain the same hard-coded user and root credentials. The user password can be easily recovered via password cracking attempts. The recovered credentials can be used to log into the device via the login shell that is exposed by the serial interface. The backdoor user has been removed in firmware BSP >= 6.4.1.
CVE-2025-26411 2026-04-15 8.8 High
An authenticated attacker is able to use the Plugin Manager of the web interface of the Wattsense Bridge devices to upload malicious Python files to the device. This enables an attacker to gain remote root access to the device. An attacker needs a valid user account on the Wattsense web interface to be able to conduct this attack. This issue is fixed in recent firmware versions BSP >= 6.1.0.
CVE-2025-26412 2026-04-15 6.8 Medium
The SIMCom SIM7600G modem supports an undocumented AT command, which allows an attacker to execute system commands with root permission on the modem. An attacker needs either physical access or remote shell access to a device that interacts directly with the modem via AT commands.
CVE-2025-26503 1 Windriver 1 Vxworks 2026-04-15 6.7 Medium
A crafted system call argument can cause memory corruption.
CVE-2025-26470 1 Intel 1 Distribution For Python 2026-04-15 6.7 Medium
Incorrect default permissions for some Intel(R) Distribution for Python software installers before version 2025.1.0 may allow an authenticated user to potentially enable escalation of privilege via local access.
CVE-2025-26472 1 Intel 1 Edge Orchestrator Software 2026-04-15 5.7 Medium
Uncontrolled resource consumption for some Edge Orchestrator software before version 24.11.1 for Intel(R) Tiber(TM) Edge Platform may allow an authenticated user to potentially enable denial of service via adjacent access.