| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| On IROAD v9 devices, the dashcam has hardcoded default credentials ("qwertyuiop") that cannot be changed by the user. This allows an attacker within Wi-Fi range to connect to the device's network to perform sniffing. |
| In the IROAD APK 5.2.5, there are Hardcoded Credentials in the APK for ports 9091 and 9092. The mobile application for the dashcam contains hardcoded credentials that allow an attacker on the local Wi-Fi network to access API endpoints and retrieve sensitive device information, including live and recorded footage. |
| On IROAD v9 devices, one can Remotely Dump Video Footage and the Live Video Stream. The dashcam exposes endpoints that allow unauthorized users, who gained access through other means, to list and download recorded videos, as well as access live video streams without proper authentication. |
| An issue was discovered on ROADCAM X3 devices. It has a uniform default credential set that cannot be modified by users, making it easy for attackers to gain unauthorized access to multiple devices. |
| An issue was discovered in the G-Net GNET APK 2.6.2. Hardcoded credentials exist in in APK for ports 9091 and 9092. The GNET mobile application contains hardcoded credentials that provide unauthorized access to the dashcam's API endpoints on ports 9091 and 9092. Once the GNET SSID is connected to, the attacker sends a crafted authentication command with TibetList and 000000 to list settings of the dashcam at port 9091. There's a separate set of credentials for port 9092 (stream) that is also exposed in cleartext: admin + tibet. For settings, the required credentials are adim + 000000. |
| A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions), UL Resi High End 40A w/15118 Hw (8EM1312-4CF18-0FA3) (All versions), UL Resi High End 48A w/15118 Hw (8EM1312-5CF18-0FA3) (All versions), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions). Affected devices do not contain an Immutable Root of Trust in M0 Hardware. An attacker with physical access to the device could use this to execute arbitrary code. |
| A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger. |
| A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX RX1400 (All versions < V2.16.5), RUGGEDCOM ROX RX1500 (All versions < V2.16.5), RUGGEDCOM ROX RX1501 (All versions < V2.16.5), RUGGEDCOM ROX RX1510 (All versions < V2.16.5), RUGGEDCOM ROX RX1511 (All versions < V2.16.5), RUGGEDCOM ROX RX1512 (All versions < V2.16.5), RUGGEDCOM ROX RX1524 (All versions < V2.16.5), RUGGEDCOM ROX RX1536 (All versions < V2.16.5), RUGGEDCOM ROX RX5000 (All versions < V2.16.5). The 'ping' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges. |
| A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX RX1400 (All versions < V2.16.5), RUGGEDCOM ROX RX1500 (All versions < V2.16.5), RUGGEDCOM ROX RX1501 (All versions < V2.16.5), RUGGEDCOM ROX RX1510 (All versions < V2.16.5), RUGGEDCOM ROX RX1511 (All versions < V2.16.5), RUGGEDCOM ROX RX1512 (All versions < V2.16.5), RUGGEDCOM ROX RX1524 (All versions < V2.16.5), RUGGEDCOM ROX RX1536 (All versions < V2.16.5), RUGGEDCOM ROX RX5000 (All versions < V2.16.5). The 'tcpdump' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges. |
| A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX RX1400 (All versions < V2.16.5), RUGGEDCOM ROX RX1500 (All versions < V2.16.5), RUGGEDCOM ROX RX1501 (All versions < V2.16.5), RUGGEDCOM ROX RX1510 (All versions < V2.16.5), RUGGEDCOM ROX RX1511 (All versions < V2.16.5), RUGGEDCOM ROX RX1512 (All versions < V2.16.5), RUGGEDCOM ROX RX1524 (All versions < V2.16.5), RUGGEDCOM ROX RX1536 (All versions < V2.16.5), RUGGEDCOM ROX RX5000 (All versions < V2.16.5). The 'traceroute' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges. |
| Successful exploitation of this vulnerability could result in the product failing to re-establish communication once the certificate expires. |
| The following APIs for the Silcon Labs SiWx91x prior to vesion 3.4.0 failed to check the size of the output buffer of the caller which could lead to data corruption on the host (Cortex-M4) application.
sl_si91x_aes
sl_si91x_gcm
sl_si91x_ccm
sl_si91x_sha |
| A vulnerability has been identified in BACnet ATEC 550-440 (All versions), BACnet ATEC 550-441 (All versions), BACnet ATEC 550-445 (All versions), BACnet ATEC 550-446 (All versions). Affected devices improperly handle specific incoming BACnet MSTP messages. This could allow an attacker residing in the same BACnet network to send a specially crafted MSTP message that results in a denial of service condition of the targeted device. A power cycle is required to restore the device's normal operation. |
| Under certain conditions, SAP Gateway Client allows a high-privileged user to access restricted information beyond the scope of the application. Due to the possibility of influencing application behavior or performance through misuse of the exposed data, this may potentially lead to low impact on confidentiality, integrity, and availability. |
| Under certain conditions Promotion Management Wizard (PMW) allows an attacker to access information which would otherwise be restricted.This has High impact on Confidentiality with Low impact on Integrity and Availability of the application. |
| SAP GUI for Windows allows an unauthenticated attacker to exploit insecure obfuscation algorithms used by the GuiXT application to store user credentials. While this issue does not impact the Integrity or Availability of the application, it may have a Low impact on the Confidentiality of data. |
| SAP Supplier Relationship Management (Master Data Management Catalogue) allows an unauthenticated attacker to execute malicious scripts in the application, potentially leading to a Cross-Site Scripting (XSS) vulnerability. This has no impact on the availability of the application, but it can have some minor impact on its confidentiality and integrity. |
| SAP S/4HANA Cloud Private Edition or on Premise (SCM Master Data Layer (MDL)) allows an authenticated attacker with SAP standard authorization to execute a certain function module remotely and replace arbitrary ABAP programs, including SAP standard programs. This is due to lack of input validation and no authorization checks. This has low Confidentiality impact but high impact on integrity and availability to the application. |
| JHipster before v.8.9.0 allows privilege escalation via a modified authorities parameter. Upon registering in the JHipster portal and logging in as a standard user, the authorities parameter in the response from the api/account endpoint contains the value ROLE_USER. By manipulating the authorities parameter and changing its value to ROLE_ADMIN, the privilege is successfully escalated to an Admin level. This allowed the access to all admin-related functionalities in the application. NOTE: this is disputed by the Supplier because there is no privilege escalation in the context of the JHipster backend (the report only demonstrates that, after using JHipster to generate an application, one can make a non-functional admin screen visible in the front end of that application). |
| The Frontend Dashboard plugin for WordPress is vulnerable to Privilege Escalation due to a missing capability check on the ajax_request() function in versions 1.0 to 2.2.7. This makes it possible for authenticated attackers, with Subscriber-level access and above, to control where the plugin sends outgoing emails. By pointing SMTP to their own server, attackers could capture password reset emails intended for administrators, and elevate their privileges for full site takeover. |