Search

Search Results (365286 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-40673 2026-04-15 N/A
A Missing Authorization vulnerability has been found in DinoRANK. This vulnerability allows an attacker to access invoices of any user via accessing endpoint '/facturas/YYYY-MM/SDRYYMM-XXXXX.pdf' because there is no access control. The pdf filename can be obtained via OSINT, insecure network traffic or brute force.
CVE-2025-40677 1 Summar 1 Portal Del Empleado 2026-04-15 N/A
SQL injection vulnerability in Summar Software´s Portal del Empleado. This vulnerability allows an attacker to retrieve, create, update, and delete the database by sending a POST request using the parameter “ctl00$ContentPlaceHolder1$filtroNombre” in “/MemberPages/quienesquien.aspx”.
CVE-2025-40678 1 Summar 1 Portal Del Empleado 2026-04-15 N/A
Unrestricted upload vulnerability for dangerous file types on Summar Software´s Portal del Empleado. This vulnerability allows an attacker to upload a dangerous file type by sending a POST request using the parameter “cctl00$ContentPlaceHolder1$fuAdjunto” in “/MemberPages/ntf_absentismo.aspx”.
CVE-2025-34074 2026-04-15 N/A
An authenticated remote code execution vulnerability exists in Lucee’s administrative interface due to insecure design in the scheduled task functionality. An administrator with access to /lucee/admin/web.cfm can configure a scheduled job to retrieve a remote .cfm file from an attacker-controlled server, which is written to the Lucee webroot and executed with the privileges of the Lucee service account. Because Lucee does not enforce integrity checks, path restrictions, or execution controls for scheduled task fetches, this feature can be abused to achieve arbitrary code execution. This issue is distinct from CVE-2024-55354.
CVE-2025-40726 2026-04-15 N/A
Reflected Cross-Site Scripting (XSS) vulnerability in /pages/search-results-page in Nosto, which allows remote attackers to execute arbitrary code via the q GET request parameter.
CVE-2025-40710 2026-04-15 N/A
Host Header Injection (HHI) vulnerability in the Hotspot Shield VPN client, which can induce unexpected behaviour when accessing third-party web applications through the VPN tunnel. Although such applications do not present this vulnerability per se, the use of the tunnel, together with a forged Host header, can cause the VPN client to redirect or forward HTTP requests to servers other than those originally intended, leading to consequences such as open redirects or delivery of traffic to infrastructure controlled by an attacker. This does not imply a flaw in the target applications, but in how the VPN client internally handles outgoing headers and requests.
CVE-2025-40722 2026-04-15 N/A
Stored Cross-Site Scripting (XSS) vulnerability in versions prior to Flatboard 3.2.2 of Flatboard Pro, consisting of a stored XSS due to lack of proper validation of user input, through the replace parameter in /config.php/tags.
CVE-2025-40723 2026-04-15 N/A
Stored Cross-Site Scripting (XSS) vulnerability in versions prior to Flatboard 3.2.2 of Flatboard Pro, consisting of a stored XSS due to lack of proper validation of user input, through the footer_text and announcement parameters in config.php.
CVE-2025-40724 2026-04-15 N/A
Stored Cross-Site Scripting (XSS) vulnerability in Pharmacy POS PHP Script. This vulnerability allows an attacker to execute JavaScript code in the victim's browser by sending the victim a malicious URL using the u_medicine_name parameter in /edit_medicine.php. This vulnerability can be exploited to steal sensitive user data such as session cookies or to perform actions on behalf of the user.
CVE-2025-40743 1 Siemens 4 Sinumerik 828d, Sinumerik 840d Sl, Sinumerik Mc and 1 more 2026-04-15 8.3 High
A vulnerability has been identified in SINUMERIK 828D PPU.4 (All versions < V4.95 SP5), SINUMERIK 828D PPU.5 (All versions < V5.25 SP1), SINUMERIK 840D sl (All versions < V4.95 SP5), SINUMERIK MC (All versions < V1.25 SP1), SINUMERIK MC V1.15 (All versions < V1.15 SP5), SINUMERIK ONE (All versions < V6.25 SP1), SINUMERIK ONE V6.15 (All versions < V6.15 SP5). The affected application improperly validates authentication for its VNC access service, allowing access with insufficient password verification. This could allow an attacker to gain unauthorized remote access and potentially compromise system confidentiality, integrity, or availability.
CVE-2025-4075 2026-04-15 4.3 Medium
A vulnerability was found in VMSMan up to 20250416. It has been rated as problematic. Affected by this issue is some unknown functionality of the file /login.php. The manipulation of the argument Email with the input "><script>alert(1)</script> leads to cross site scripting. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-40752 1 Siemens 2 Q100, Q200 2026-04-15 6.2 Medium
A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices store the password for the SMTP account as plain text. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes.
CVE-2025-40753 1 Siemens 2 Q100, Q200 2026-04-15 6.2 Medium
A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices export the password for the SMTP account as plain text in the Configuration File. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes.
CVE-2025-40757 1 Siemens 2 Apogee Pxc, Talon Tc 2026-04-15 5.3 Medium
A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC Series (BACnet) (All versions). Affected devices connected to the network allow unrestricted access to sensitive files, such as databases. This could allow an attacker to download encrypted .db file containing passwords.
CVE-2025-40758 1 Mendix 2 Mendix, Saml 2026-04-15 8.7 High
A vulnerability has been identified in Mendix SAML (Mendix 10.12 compatible) (All versions < V4.0.3), Mendix SAML (Mendix 10.21 compatible) (All versions < V4.1.2), Mendix SAML (Mendix 9.24 compatible) (All versions < V3.6.21). Affected versions of the module insufficiently enforce signature validation and binding checks. This could allow unauthenticated remote attackers to hijack an account in specific SSO configurations.
CVE-2025-40759 2026-04-15 7.8 High
A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2). Affected products do not properly sanitize stored security properties when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
CVE-2025-40761 1 Siemens 11 Ruggedcom Rox Mx5000, Ruggedcom Rox Mx5000re, Ruggedcom Rox Rx1400 and 8 more 2026-04-15 7.6 High
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions), RUGGEDCOM ROX MX5000RE (All versions), RUGGEDCOM ROX RX1400 (All versions), RUGGEDCOM ROX RX1500 (All versions), RUGGEDCOM ROX RX1501 (All versions), RUGGEDCOM ROX RX1510 (All versions), RUGGEDCOM ROX RX1511 (All versions), RUGGEDCOM ROX RX1512 (All versions), RUGGEDCOM ROX RX1524 (All versions), RUGGEDCOM ROX RX1536 (All versions), RUGGEDCOM ROX RX5000 (All versions). Affected devices do not properly limit access through its Built-In-Self-Test (BIST) mode. This could allow an attacker with physical access to the serial interface to bypass authentication and get access to a root shell on the device.
CVE-2025-4076 2026-04-15 6.3 Medium
A vulnerability classified as critical has been found in LB-LINK BL-AC3600 up to 1.0.22. This affects the function easy_uci_set_option_string_0 of the file /cgi-bin/lighttpd.cgi of the component Password Handler. The manipulation of the argument routepwd leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-40769 1 Siemens 1 Sinec Traffic Analyzer 2026-04-15 7.4 High
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V3.0). The affected application uses a Content Security Policy that allows unsafe script execution methods. This could allow an attacker to execute unauthorized scripts, potentially leading to cross-site scripting attacks.
CVE-2025-40771 1 Siemens 6 Simatic Cp 1542sp-1, Simatic Cp 1542sp-1 Irc, Simatic Cp 1543sp-1 and 3 more 2026-04-15 9.8 Critical
A vulnerability has been identified in SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.4.24). Affected devices do not properly authenticate configuration connections. This could allow an unauthenticated remote attacker to access the configuration data.