| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| NVIDIA nvJPEG2000 library contains a vulnerability where an attacker can cause an out-of-bounds write issue by means of a specially crafted JPEG2000 file. A successful exploit of this vulnerability might lead to code execution and data tampering. |
| Codigo Markdown Editor 1.0.1 contains a code execution vulnerability that allows attackers to run arbitrary system commands by crafting a malicious markdown file. Attackers can embed a video source with an onerror event that executes shell commands through Node.js child_process module when the file is opened. |
| In the Linux kernel, the following vulnerability has been resolved:
md: raid1: fix potential OOB in raid1_remove_disk()
If rddev->raid_disk is greater than mddev->raid_disks, there will be
an out-of-bounds in raid1_remove_disk(). We have already found
similar reports as follows:
1) commit d17f744e883b ("md-raid10: fix KASAN warning")
2) commit 1ebc2cec0b7d ("dm raid: fix KASAN warning in raid5_remove_disk")
Fix this bug by checking whether the "number" variable is
valid. |
| Trimble TM4Web 22.2.0 allows unauthenticated attackers to access /inc/tm_ajax.msw?func=UserfromUUID&uuid= to retrieve the last registration access code and use this access code to register a valid account. via a PUT /inc/tm_ajax.msw request. If the access code was used to create an Administrator account, attackers are also able to register new Administrator accounts with full privileges. |
| The MouseTooltipTranslator Chrome extension allows mouseover translation of any language at once. The MouseTooltipTranslator browser extension is vulnerable to SSRF attacks. The pdf.mjs script uses the URL parameter from the current URL as the file to download and display to the extension user. Because pdf.mjs is imported in viewer.html and viewer.html is accessible to all URLs, an attacker can force the user’s browser to make a request to any arbitrary URL. After discussion with maintainer, patching this issue would require disabling a major feature of the extension in exchange for a low severity vulnerability. Decision to not patch issue. |
| The pwrstudio web application of EV Charger (in the server in Circontrol Raption through 5.6.2) is vulnerable to OS command injection via three fields of the configuration menu for ntpserver0, ntpserver1, and pingip. |
| The KuWFi 4G AC900 LTE router 1.0.13 is vulnerable to command injection on the HTTP API endpoints /goform/formMultiApnSetting and /goform/atCmd. An authenticated attacker can execute arbitrary OS commands with root privileges via shell metacharacters in parameters such as pincode and cmds. Exploitation can lead to full system compromise, including enabling remote access (e.g., enabling telnet). |
| sp-php-email-handler is a PHP package for handling contact form submissions. Messages sent using this script are vulnerable to abuse, as the script allows anybody to specify arbitrary email recipients and include user-provided content in confirmation emails. This could enable malicious actors to use your server to send spam, phishing emails, or other malicious content, potentially damaging your domain's reputation and leading to blacklisting by email providers. Patched in version 1.0.0 by removing user-provided content from confirmation emails. All pre-release versions (alpha and beta) are vulnerable to this issue and should not be used. There are no workarounds for this issue. Users must upgrade to version 1.0.0 to mitigate the vulnerability. |
| mime.php in SquirrelMail through 1.4.23-svn-20250401 and 1.5.x through 1.5.2-svn-20250401 allows XSS via e-mail headers, because JavaScript payloads are mishandled after $encoded has been set to true. |
| Protection Mechanism Failure vulnerability in ESTsoft ALZip on Windows allows SmartScreen bypass.This issue affects ALZip: from 12.01 before 12.29. |
| imFAQ is an advanced questions and answers management system for ImpressCMS. Prior to 1.0.1, if the $_GET['seoOp'] parameter is manipulated to include malicious input (e.g., seoOp=php://filter/read=convert.base64-encode/resource=/var/www/html/config.php), the application could allow an attacker to read sensitive files on the server (Local File Inclusion, LFI). The $_GET['seoOp'] and $_GET['seoArg'] parameters are directly used without sanitization or validation. This is partly mitigated by the fact that the ImpressCMS sensitive files are stored outside the web root, in a folder with a randomized name. The issue has been resolved in imFaq 1.0.1. |
| Emerson ValveLink products
do not use or incorrectly uses a protection mechanism that provides
sufficient defense against directed attacks against the product. |
| On IROAD v9 devices, the dashcam has hardcoded default credentials ("qwertyuiop") that cannot be changed by the user. This allows an attacker within Wi-Fi range to connect to the device's network to perform sniffing. |
| In the IROAD APK 5.2.5, there are Hardcoded Credentials in the APK for ports 9091 and 9092. The mobile application for the dashcam contains hardcoded credentials that allow an attacker on the local Wi-Fi network to access API endpoints and retrieve sensitive device information, including live and recorded footage. |
| On IROAD v9 devices, one can Remotely Dump Video Footage and the Live Video Stream. The dashcam exposes endpoints that allow unauthorized users, who gained access through other means, to list and download recorded videos, as well as access live video streams without proper authentication. |
| An issue was discovered on ROADCAM X3 devices. It has a uniform default credential set that cannot be modified by users, making it easy for attackers to gain unauthorized access to multiple devices. |
| An issue was discovered in the G-Net GNET APK 2.6.2. Hardcoded credentials exist in in APK for ports 9091 and 9092. The GNET mobile application contains hardcoded credentials that provide unauthorized access to the dashcam's API endpoints on ports 9091 and 9092. Once the GNET SSID is connected to, the attacker sends a crafted authentication command with TibetList and 000000 to list settings of the dashcam at port 9091. There's a separate set of credentials for port 9092 (stream) that is also exposed in cleartext: admin + tibet. For settings, the required credentials are adim + 000000. |
| A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions), UL Resi High End 40A w/15118 Hw (8EM1312-4CF18-0FA3) (All versions), UL Resi High End 48A w/15118 Hw (8EM1312-5CF18-0FA3) (All versions), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions). Affected devices do not contain an Immutable Root of Trust in M0 Hardware. An attacker with physical access to the device could use this to execute arbitrary code. |
| A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger. |
| A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX RX1400 (All versions < V2.16.5), RUGGEDCOM ROX RX1500 (All versions < V2.16.5), RUGGEDCOM ROX RX1501 (All versions < V2.16.5), RUGGEDCOM ROX RX1510 (All versions < V2.16.5), RUGGEDCOM ROX RX1511 (All versions < V2.16.5), RUGGEDCOM ROX RX1512 (All versions < V2.16.5), RUGGEDCOM ROX RX1524 (All versions < V2.16.5), RUGGEDCOM ROX RX1536 (All versions < V2.16.5), RUGGEDCOM ROX RX5000 (All versions < V2.16.5). The 'ping' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges. |