Search

Search Results (363387 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-30516 2 Saasproject, Wordpress 2 Booking Package, Wordpress 2026-04-15 7.5 High
Improper Validation of Specified Quantity in Input vulnerability in SaasProject Booking Package allows Accessing Functionality Not Properly Constrained by ACLs.This issue affects Booking Package: from n/a through 1.6.27.
CVE-2025-42982 2026-04-15 8.8 High
SAP GRC allows a non-administrative user to access and initiate transaction which could allow them to modify or control the transmitted system credentials. This causes high impact on confidentiality, integrity and availability of the application.
CVE-2024-37372 2026-04-15 3.6 Low
The Permission Model assumes that any path starting with two backslashes \ has a four-character prefix that can be ignored, which is not always true. This subtle bug leads to vulnerable edge cases.
CVE-2025-42983 2026-04-15 8.5 High
SAP Business Warehouse and SAP Plug-In Basis allows an authenticated attacker to drop arbitrary SAP database tables, potentially resulting in a loss of data or rendering the system unusable. On successful exploitation, an attacker can completely delete database entries but is not able to read any data.
CVE-2024-38821 1 Spring 1 Webflux 2026-04-15 9.1 Critical
Spring WebFlux applications that have Spring Security authorization rules on static resources can be bypassed under certain circumstances. For this to impact an application, all of the following must be true: * It must be a WebFlux application * It must be using Spring's static resources support * It must have a non-permitAll authorization rule applied to the static resources support
CVE-2024-39205 1 Pyload-ng Project 1 Pyload-ng 2026-04-15 9.8 Critical
An issue in pyload-ng v0.5.0b3.dev85 running under python3.11 or below allows attackers to execute arbitrary code via a crafted HTTP request.
CVE-2025-42984 2026-04-15 5.4 Medium
SAP S/4HANA Manage Central Purchase Contract does not perform necessary authorization checks for an authenticated user. Due to this, an attacker could execute the function import on the entity making it inaccessible for unrestricted user. This has low impact on confidentiality and availability of the application.
CVE-2024-40762 1 Sonicwall 1 Sonicos 2026-04-15 9.8 Critical
Use of Cryptographically Weak Pseudo-Random Number Generator (PRNG) in the SonicOS SSLVPN authentication token generator that, in certain cases, can be predicted by an attacker potentially resulting in authentication bypass.
CVE-2024-42011 1 Spotify 1 Spotify App 2026-04-15 7.5 High
The Spotify app 8.9.58 for iOS has a buffer overflow in its use of strcat.
CVE-2024-42028 1 Ubiquiti 1 Unifi Network Application 2026-04-15 8.8 High
A Local privilege escalation vulnerability found in a Self-Hosted UniFi Network Server with UniFi Network Application (Version 8.4.62 and earlier) allows a malicious actor with a local operational system user to execute high privilege actions on UniFi Network Server.
CVE-2025-42985 2026-04-15 6.1 Medium
Due to insufficient sanitization in the SAP BusinessObjects Content Administrator Workbench, attackers could craft malicious URLs and execute scripts in a victim�s browser. This could potentially lead to the exposure or modification of web client data, resulting in low impact on confidentiality and integrity, with no impact on application availability.
CVE-2024-43650 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
CVE-2025-42987 2026-04-15 4.3 Medium
SAP Manage Processing Rules (For Bank Statement) allows an attacker with basic privileges to edit shared rules of any user by tampering the request parameter. Due to missing authorization check, the attacker can edit rules that should be restricted, compromising the integrity of the application.
CVE-2024-42818 1 Fastapi-admin 1 Fastapi-admin Pro 2026-04-15 6.1 Medium
A cross-site scripting (XSS) vulnerability in the Config-Create function of fastapi-admin pro v0.1.4 allows attackers to execute arbitrary web scripts or HTML via a crafted payload injected into the Product Name parameter.
CVE-2024-43651 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
CVE-2025-42989 1 Sap 1 Netweaver Application Server For Abap 2026-04-15 9.6 Critical
RFC inbound processing�does not perform necessary authorization checks for an authenticated user, resulting in escalation of privileges. On successful exploitation the attacker could critically impact both integrity and availability of the application.
CVE-2025-42990 2026-04-15 3 Low
Unprotected SAPUI5 applications allow an attacker with basic privileges to inject malicious HTML code into a webpage, with the goal of redirecting users to the attacker controlled URL. This issue could impact the integrity of the application. Confidentiality or Availability are not impacted.
CVE-2024-43656 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43657 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43660 2026-04-15 7.5 High
The CGI script <redacted>.sh can be used to download any file on the filesystem. This issue affects Iocharger firmware for AC model chargers beforeversion 24120701. Likelihood: High, but credentials required. Impact: Critical – The script can be used to download any file on the filesystem, including sensitive files such as /etc/shadow, the CGI script source code or binaries and configuration files. CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/S:P/AU:Y CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The confidentiality of all files of the devicd can be compromised (VC:H/VI:N/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, this attack in isolation does not have a safety impact. The attack can be automated (AU:Y).