| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Parse Server is an open source backend that can be deployed to any infrastructure that can run Node.js. Starting in 5.3.0 and before 7.5.3 and 8.2.2, the Parse Server GraphQL API previously allowed public access to the GraphQL schema without requiring a session token or the master key. While schema introspection reveals only metadata and not actual data, this metadata can still expand the potential attack surface. This vulnerability is fixed in 7.5.3 and 8.2.2. |
| A DLL hijacking vulnerability in Vivado could allow a local attacker to achieve privilege escalation, potentially resulting in arbitrary code execution. |
| A vulnerability exists in Advantech iView that allows for argument
injection in NetworkServlet.backupDatabase(). This issue requires an
authenticated attacker with at least user-level privileges. Certain
parameters can be used directly in a command without proper
sanitization, allowing arbitrary arguments to be injected. This can
result in information disclosure, including sensitive database
credentials. |
| iib0011 omni-tools v0.4.0 is vulnerable to remote code execution via unsafe JSON deserialization. |
| An open redirect vulnerability exists in Byaidu PDFMathTranslate v1.9.9 that allows attackers to craft URLs that cause the application to redirect users to arbitrary external websites via the file parameter to the /gradio_api endpoint. This vulnerability could be exploited for phishing attacks or to bypass security filters. |
| Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to disclose information such as generated power and electricity sold back to the grid stored in the product, tamper with or destroy stored or configured information in the product, or cause a Denial-of-Service (DoS) condition on the product, by using hardcoded user ID and password common to the product series obtained by exploiting CVE-2025-5022. The affected products discontinued in 2015, support ended in 2020. |
| Weak Password Requirements vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to derive the password from the SSID. In addition, if the product is configured to enable the individual air conditioner control function, an attacker who has access to the Wi-Fi communication between the units by exploiting this vulnerability may be able to execute ECHONET Lite commands to perform operations such as turning the air conditioner on or off and changing the set temperature. The individual air conditioner control function is available only in display unit version 02.00.01 or later and measurement unit version 02.03.01 or later. The affected products discontinued in 2015, support ended in 2020. |
| The sr_feuser_register extension through 12.4.8 for TYPO3 allows Remote Code Execution. |
| Git GUI allows you to use the Git source control management tools via a GUI. When a user clones an untrusted repository and is tricked into editing a file located in a maliciously named directory in the repository, then Git GUI can create and overwrite files for which the user has write permission. This vulnerability is fixed in 2.43.7, 2.44.4, 2.45.4, 2.46.4, 2.47.3, 2.48.2, 2.49.1, and 2.50.1. |
| Improper input validation in AMD Graphics Driver could allow a local attacker to write out of bounds, potentially resulting in loss of integrity or denial of service. |
| A Privilege Context Switching Error (CWE-270) in the Command Center Server could allow a privileged Operator with high level access in one Division to perform limited privileged activities across the Division boundary.
This issue affects Command Centre Server:
9.30 prior to 9.30.1874 (MR1), 9.20 prior to 9.20.2337 (MR3), 9.10 prior to 9.10.3194 (MR6), 9.00 prior to 9.00.3371 (MR7), all versions of 8.90 and prior. |
| Emerson ValveLink products
do not use or incorrectly uses a protection mechanism that provides
sufficient defense against directed attacks against the product. |
| A DLL hijacking vulnerability in the AMD Software Installer could allow an attacker to achieve privilege escalation potentially resulting in arbitrary code execution. |
| Ecovacs Deebot T10 1.7.2 transmits Wi-Fi credentials in cleartext during the pairing process. |
| COMMAX Biometric Access Control System 1.0.0 contains an unauthenticated reflected cross-site scripting vulnerability in cookie parameters 'CMX_ADMIN_NM' and 'CMX_COMPLEX_NM'. Attackers can inject malicious HTML and JavaScript code into these cookie values to execute arbitrary scripts in a victim's browser session. |
| KZTech JT3500V 4G LTE CPE 2.0.1 contains a session management vulnerability that allows attackers to reuse old session credentials without proper expiration. Attackers can exploit the weak session handling to maintain unauthorized access and potentially compromise device authentication mechanisms. |
| NuCom 11N Wireless Router 5.07.90 contains a privilege escalation vulnerability that allows non-privileged users to access administrative credentials through the configuration backup endpoint. Attackers can send a crafted HTTP GET request to the backup configuration page with a specific cookie to retrieve and decode the admin password in Base64 format. |
| SAP NetWeaver Enterprise Portal Administration is vulnerable when a privileged user can upload untrusted or malicious content which, when deserialized, could potentially lead to a compromise of confidentiality, integrity, and availability of the host system. |
| The upload endpoint insufficiently validates the 'Upload-Key' request header. By supplying path traversal sequences, an authenticated attacker can cause the server to create upload-related artifacts outside the intended storage location. In certain configurations this enables arbitrary file write and may be leveraged to achieve remote code execution. |
| meterN 1.2.3 contains an authenticated remote code execution vulnerability in admin_meter2.php and admin_indicator2.php scripts. Attackers can exploit the 'COMMANDx' and 'LIVECOMMANDx' POST parameters to execute arbitrary system commands with administrative privileges. |