| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A flaw has been found in TOTVS Portal Meu RH up to 12.1.17. Impacted is an unknown function of the component Password Reset Handler. Executing manipulation of the argument redirectUrl can lead to open redirect. The attack may be performed from a remote location. The exploit has been published and may be used. Upgrading to version 12.1.2410.274, 12.1.2502.178 and 12.1.2506.121 is recommended to address this issue. It is recommended to upgrade the affected component. The vendor explains, that "[o]ur internal validation (...) confirms that the reported behavior does not exist in currently supported releases. In these tests, the redirectUrl parameter is ignored, and no malicious redirection occurs." This vulnerability only affects products that are no longer supported by the maintainer. |
| On IROAD v9 devices, the dashcam has hardcoded default credentials ("qwertyuiop") that cannot be changed by the user. This allows an attacker within Wi-Fi range to connect to the device's network to perform sniffing. |
| In the IROAD APK 5.2.5, there are Hardcoded Credentials in the APK for ports 9091 and 9092. The mobile application for the dashcam contains hardcoded credentials that allow an attacker on the local Wi-Fi network to access API endpoints and retrieve sensitive device information, including live and recorded footage. |
| An issue was discovered on ROADCAM X3 devices. It has a uniform default credential set that cannot be modified by users, making it easy for attackers to gain unauthorized access to multiple devices. |
| A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions), UL Resi High End 40A w/15118 Hw (8EM1312-4CF18-0FA3) (All versions), UL Resi High End 48A w/15118 Hw (8EM1312-5CF18-0FA3) (All versions), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions). Affected devices do not contain an Immutable Root of Trust in M0 Hardware. An attacker with physical access to the device could use this to execute arbitrary code. |
| MariaDB Server 10.4 before 10.4.33, 10.5 before 10.5.24, 10.6 before 10.6.17, 10.7 through 10.11 before 10.11.7, 11.0 before 11.0.5, and 11.1 before 11.1.4 calls fix_fields_if_needed under mysql_derived_prepare when derived is not yet prepared, leading to a find_field_in_table crash. |
| MariaDB Server 10.4 through 10.5.*, 10.6 through 10.6.*, 10.7 through 10.11.*, and 11.0 through 11.0.* can sometimes crash with an empty backtrace log. This may be related to make_aggr_tables_info and optimize_stage2. |
| MariaDB Server 10.4 through 10.5.*, 10.6 through 10.6.*, 10.7 through 10.11.*, 11.0 through 11.0.*, and 11.1 through 11.4.* crashes in Item_direct_view_ref::derived_field_transformer_for_where. |
| The following APIs for the Silcon Labs SiWx91x prior to vesion 3.4.0 failed to check the size of the output buffer of the caller which could lead to data corruption on the host (Cortex-M4) application.
sl_si91x_aes
sl_si91x_gcm
sl_si91x_ccm
sl_si91x_sha |
| A vulnerability has been identified in BACnet ATEC 550-440 (All versions), BACnet ATEC 550-441 (All versions), BACnet ATEC 550-445 (All versions), BACnet ATEC 550-446 (All versions). Affected devices improperly handle specific incoming BACnet MSTP messages. This could allow an attacker residing in the same BACnet network to send a specially crafted MSTP message that results in a denial of service condition of the targeted device. A power cycle is required to restore the device's normal operation. |
| Under certain conditions Promotion Management Wizard (PMW) allows an attacker to access information which would otherwise be restricted.This has High impact on Confidentiality with Low impact on Integrity and Availability of the application. |
| SAP GUI for Windows allows an unauthenticated attacker to exploit insecure obfuscation algorithms used by the GuiXT application to store user credentials. While this issue does not impact the Integrity or Availability of the application, it may have a Low impact on the Confidentiality of data. |
| SAP Supplier Relationship Management (Master Data Management Catalogue) allows an unauthenticated attacker to execute malicious scripts in the application, potentially leading to a Cross-Site Scripting (XSS) vulnerability. This has no impact on the availability of the application, but it can have some minor impact on its confidentiality and integrity. |
| SAP S/4HANA Cloud Private Edition or on Premise (SCM Master Data Layer (MDL)) allows an authenticated attacker with SAP standard authorization to execute a certain function module remotely and replace arbitrary ABAP programs, including SAP standard programs. This is due to lack of input validation and no authorization checks. This has low Confidentiality impact but high impact on integrity and availability to the application. |
| Prolink 4G LTE Mobile Wi-Fi DL-7203E V4.0.0B05 is vulnerable to Cross Site Scripting (XSS) in the /reqproc/proc_get endpoint. The vulnerability arises because the cmd parameter does not properly sanitize input and the response is served with a Content-Type of text/html. This behavior allows the browser to execute injected JavaScript code. |
| The Frontend Dashboard plugin for WordPress is vulnerable to Privilege Escalation due to a missing capability check on the fed_admin_setting_form_function() function in versions 1.0 to 2.2.7. This makes it possible for authenticated attackers, with Subscriber-level access and above, to overwrite the plugin’s 'register' role setting to make new user registrations default to the administrator role, leading to an elevation of privileges to that of an administrator. |
| Incorrect access control in M2Soft CROWNIX Report & ERS affected v7.x to v7.4.3.599 and v8.x to v8.0.3.79 allows unauthorized attackers to obtain Administrator account access. |
| An arbitrary file upload vulnerability in M2Soft CROWNIX Report & ERS v5.x to v5.5.14.1070, v7.x to v7.4.3.960, and v8.x to v8.2.0.345 allows attackers to execute arbitrary code via supplying a crafted file. |
| Varnish Cache before 7.6.3 and 7.7 before 7.7.1, and Varnish Enterprise before 6.0.13r14, allow client-side desync via HTTP/1 requests, because the product incorrectly permits CRLF to be skipped to delimit chunk boundaries. |
| A vulnerability classified as critical has been found in Sony SNC-M1, SNC-M3, SNC-RZ25N, SNC-RZ30N, SNC-DS10, SNC-CS3N and SNC-RX570N up to 1.30. This affects an unknown part of the component Administrative Interface. The manipulation leads to use of default credentials. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. It is recommended to change the configuration settings. The vendor was contacted early about this issue. They confirmed the existence but pointed out that they "have published the 'Hardening Guide' on the Web from July 2018 to January 2025 and have thoroughly informed customers of the recommendation to change their initial passwords". |