Search

Search Results (375084 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-42967 2026-04-15 9.9 Critical
SAP S/4HANA and SAP SCM Characteristic Propagation has remote code execution vulnerability. This allows an attacker with user level privileges to create a new report with his own code potentially gaining full control of the affected SAP system causing high impact on confidentiality, integrity, and availability of the application.
CVE-2025-42969 2026-04-15 6.1 Medium
SAP NetWeaver Application Server ABAP and ABAP Platform allows an unauthenticated attacker to inject a malicious script into a dynamically crafted URL. The victim, when tricked into clicking on this crafted URL unknowingly executes the malicious payload in their browser. On successful exploitation, the attacker can access or modify sensitive information within the scope of victim's web browser, with no impact on availability of the application.
CVE-2025-42975 1 Sap 5 Application Server, Netweaver, Netweaver Abap and 2 more 2026-04-15 6.1 Medium
SAP NetWeaver Application Server ABAP (BIC Document) allows an unauthenticated attacker to craft a URL link which, when accessed on the BIC Document application, embeds a malicious script. When a victim clicks on this link, the script executes in the victim's browser, allowing the attacker to access and/or modify information related to the web client without affecting availability.
CVE-2024-21503 2 Python Software Foundation, Redhat 2 Black, Ansible Automation Platform 2026-04-15 5.3 Medium
Versions of the package black before 24.3.0 are vulnerable to Regular Expression Denial of Service (ReDoS) via the lines_with_leading_tabs_expanded function in the strings.py file. An attacker could exploit this vulnerability by crafting a malicious input that causes a denial of service. Exploiting this vulnerability is possible when running Black on untrusted input, or if you habitually put thousands of leading tab characters in your docstrings.
CVE-2024-21542 1 Spotify 1 Luigi 2026-04-15 8.6 High
Versions of the package luigi before 3.6.0 are vulnerable to Arbitrary File Write via Archive Extraction (Zip Slip) due to improper destination file path validation in the _extract_packages_archive function.
CVE-2024-23843 2026-04-15 2.2 Low
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability in Genians Genian NAC V5.0, Genians Genian NAC LTS V5.0.This issue affects Genian NAC V5.0: from V5.0.0 through V5.0.60; Genian NAC LTS V5.0: from 5.0.0 LTS through 5.0.55 LTS(Revision 125558), from 5.0.0 LTS through 5.0.56 LTS(Revision 125560).
CVE-2025-42978 2026-04-15 3.5 Low
The widely used component that establishes outbound TLS connections in SAP NetWeaver Application Server Java does not reliably match the hostname that is used for the connection against the wildcard hostname defined in the received certificate of remote TLS server. This might lead to the outbound connection being established to a possibly malicious remote TLS server and hence disclose information. Integrity and Availability are not impacted.
CVE-2024-28335 2026-04-15 9.1 Critical
Lektor before 3.3.11 does not sanitize DB path traversal. Thus, shell commands might be executed via a file that is added to the templates directory, if the victim's web browser accesses an untrusted website that uses JavaScript to send requests to localhost port 5000, and the web browser is running on the same machine as the "lektor server" command.
CVE-2025-34030 2026-04-15 N/A
An OS command injection vulnerability exists in sar2html version 3.2.2 and prior via the plot parameter in index.php. The application fails to sanitize user-supplied input before using it in a system-level context. Remote, unauthenticated attackers can inject shell commands by appending them to the plot parameter (e.g., ?plot=;id) in a crafted GET request. The output of the command is displayed in the application's interface after interacting with the host selection UI. Successful exploitation leads to arbitrary command execution on the underlying system. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-04 UTC.
CVE-2025-34179 1 Netsupport 1 Netsupport Manager 2026-04-15 N/A
NetSupport Manager < 14.12.0001 contains an unauthenticated SQL injection vulnerability in its Connectivity Server/Gateway HTTPS request handling. The server evaluates request URIs using an unsanitized SQLite query against the FileLinks table in gateway.db. By injecting SQL through the LinkName/URI value, a remote attacker can control the FileName field used by the server to read and return files from disk, resulting in arbitrary local file disclosure.
CVE-2024-37372 2026-04-15 3.6 Low
The Permission Model assumes that any path starting with two backslashes \ has a four-character prefix that can be ignored, which is not always true. This subtle bug leads to vulnerable edge cases.
CVE-2024-38821 1 Spring 1 Webflux 2026-04-15 9.1 Critical
Spring WebFlux applications that have Spring Security authorization rules on static resources can be bypassed under certain circumstances. For this to impact an application, all of the following must be true: * It must be a WebFlux application * It must be using Spring's static resources support * It must have a non-permitAll authorization rule applied to the static resources support
CVE-2024-40762 1 Sonicwall 1 Sonicos 2026-04-15 9.8 Critical
Use of Cryptographically Weak Pseudo-Random Number Generator (PRNG) in the SonicOS SSLVPN authentication token generator that, in certain cases, can be predicted by an attacker potentially resulting in authentication bypass.
CVE-2024-42011 1 Spotify 1 Spotify App 2026-04-15 7.5 High
The Spotify app 8.9.58 for iOS has a buffer overflow in its use of strcat.
CVE-2024-42028 1 Ubiquiti 1 Unifi Network Application 2026-04-15 8.8 High
A Local privilege escalation vulnerability found in a Self-Hosted UniFi Network Server with UniFi Network Application (Version 8.4.62 and earlier) allows a malicious actor with a local operational system user to execute high privilege actions on UniFi Network Server.
CVE-2025-42985 2026-04-15 6.1 Medium
Due to insufficient sanitization in the SAP BusinessObjects Content Administrator Workbench, attackers could craft malicious URLs and execute scripts in a victim�s browser. This could potentially lead to the exposure or modification of web client data, resulting in low impact on confidentiality and integrity, with no impact on application availability.
CVE-2024-43650 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-42818 1 Fastapi-admin 1 Fastapi-admin Pro 2026-04-15 6.1 Medium
A cross-site scripting (XSS) vulnerability in the Config-Create function of fastapi-admin pro v0.1.4 allows attackers to execute arbitrary web scripts or HTML via a crafted payload injected into the Product Name parameter.
CVE-2024-43651 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
CVE-2024-43656 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).