Search

Search Results (408241 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-53695 1 Johnsoncontrols 1 Istar Ultra 2026-04-15 N/A
OS Command Injection in iSTAR Ultra products web application allows an authenticated attacker to gain even more privileged access ('root' user) to the device firmware.
CVE-2025-53638 2026-04-15 N/A
Solady is software that provides Solidity snippets with APIs. Starting in version 0.0.125 and prior to version 0.1.24, when an account is deployed via a proxy, using regular Solidity to call its initialization function may result in a silent failure, if the initialization function does not return a `bool` or some other return data. This is because regular Solidity uses `extcodesize(proxy)` to decide if call succeeds. This is insufficient in the case when the proxy points to an empty implementation. Users should upgrade to Solady v0.1.24 or later to receive a patch. Deploy any affected implementations and their factories on new EVM chains as soon as possible.
CVE-2024-51026 1 Netadmin 1 Netadmin 2026-04-15 5.4 Medium
The NetAdmin IAM system (version 4.0.30319) has a Cross Site Scripting (XSS) vulnerability in the /BalloonSave.ashx endpoint, where it is possible to inject a malicious payload into the Content= field.
CVE-2024-12636 2026-04-15 4.3 Medium
The Privacy Policy Generator, Terms & Conditions Generator WordPress Plugin : WP Legal Pages plugin for WordPress is vulnerable to Cross-Site Request Forgery in all versions up to, and including, 3.2.6. This is due to missing or incorrect nonce validation on the 'create_popup_delete_process' function. This makes it possible for unauthenticated attackers to delete popups via a forged request granted they can trick a site administrator into performing an action such as clicking on a link.
CVE-2025-30106 2026-04-15 8.8 High
On IROAD v9 devices, the dashcam has hardcoded default credentials ("qwertyuiop") that cannot be changed by the user. This allows an attacker within Wi-Fi range to connect to the device's network to perform sniffing.
CVE-2025-30122 2026-04-15 9.8 Critical
An issue was discovered on ROADCAM X3 devices. It has a uniform default credential set that cannot be modified by users, making it easy for attackers to gain unauthorized access to multiple devices.
CVE-2025-31929 2026-04-15 4.2 Medium
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions), UL Resi High End 40A w/15118 Hw (8EM1312-4CF18-0FA3) (All versions), UL Resi High End 48A w/15118 Hw (8EM1312-5CF18-0FA3) (All versions), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions). Affected devices do not contain an Immutable Root of Trust in M0 Hardware. An attacker with physical access to the device could use this to execute arbitrary code.
CVE-2025-36625 1 Tenable 1 Nessus 2026-04-15 4.3 Medium
In Nessus versions prior to 10.8.4, a non-authenticated attacker could alter Nessus logging entries by manipulating http requests to the application.
CVE-2023-52968 1 Mariadb 1 Mariadb 2026-04-15 4.9 Medium
MariaDB Server 10.4 before 10.4.33, 10.5 before 10.5.24, 10.6 before 10.6.17, 10.7 through 10.11 before 10.11.7, 11.0 before 11.0.5, and 11.1 before 11.1.4 calls fix_fields_if_needed under mysql_derived_prepare when derived is not yet prepared, leading to a find_field_in_table crash.
CVE-2023-52969 1 Mariadb 1 Mariadb 2026-04-15 4.9 Medium
MariaDB Server 10.4 through 10.5.*, 10.6 through 10.6.*, 10.7 through 10.11.*, and 11.0 through 11.0.* can sometimes crash with an empty backtrace log. This may be related to make_aggr_tables_info and optimize_stage2.
CVE-2023-52970 1 Mariadb 1 Mariadb 2026-04-15 4.9 Medium
MariaDB Server 10.4 through 10.5.*, 10.6 through 10.6.*, 10.7 through 10.11.*, 11.0 through 11.0.*, and 11.1 through 11.4.* crashes in Item_direct_view_ref::derived_field_transformer_for_where.
CVE-2025-3873 2026-04-15 N/A
The following APIs for the Silcon Labs SiWx91x prior to vesion 3.4.0 failed to check the size of the output buffer of the caller which could lead to data corruption on the host (Cortex-M4) application. sl_si91x_aes sl_si91x_gcm sl_si91x_ccm sl_si91x_sha
CVE-2025-40556 2026-04-15 6.5 Medium
A vulnerability has been identified in BACnet ATEC 550-440 (All versions), BACnet ATEC 550-441 (All versions), BACnet ATEC 550-445 (All versions), BACnet ATEC 550-446 (All versions). Affected devices improperly handle specific incoming BACnet MSTP messages. This could allow an attacker residing in the same BACnet network to send a specially crafted MSTP message that results in a denial of service condition of the targeted device. A power cycle is required to restore the device's normal operation.
CVE-2025-43000 2026-04-15 7.9 High
Under certain conditions Promotion Management Wizard (PMW) allows an attacker to access information which would otherwise be restricted.This has High impact on Confidentiality with Low impact on Integrity and Availability of the application.
CVE-2025-43005 2026-04-15 4.3 Medium
SAP GUI for Windows allows an unauthenticated attacker to exploit insecure obfuscation algorithms used by the GuiXT application to store user credentials. While this issue does not impact the Integrity or Availability of the application, it may have a Low impact on the Confidentiality of data.
CVE-2025-43006 2026-04-15 6.1 Medium
SAP Supplier Relationship Management (Master Data Management Catalogue) allows an unauthenticated attacker to execute malicious scripts in the application, potentially leading to a Cross-Site Scripting (XSS) vulnerability. This has no impact on the availability of the application, but it can have some minor impact on its confidentiality and integrity.
CVE-2025-43010 2026-04-15 8.3 High
SAP S/4HANA Cloud Private Edition or on Premise (SCM Master Data Layer (MDL)) allows an authenticated attacker with SAP standard authorization to execute a certain function module remotely and replace arbitrary ABAP programs, including SAP standard programs. This is due to lack of input validation and no authorization checks. This has low Confidentiality impact but high impact on integrity and availability to the application.
CVE-2024-57237 2026-04-15 6.3 Medium
Prolink 4G LTE Mobile Wi-Fi DL-7203E V4.0.0B05 is vulnerable to Cross Site Scripting (XSS) in the /reqproc/proc_get endpoint. The vulnerability arises because the cmd parameter does not properly sanitize input and the response is served with a Content-Type of text/html. This behavior allows the browser to execute injected JavaScript code.
CVE-2025-4474 2026-04-15 8.8 High
The Frontend Dashboard plugin for WordPress is vulnerable to Privilege Escalation due to a missing capability check on the fed_admin_setting_form_function() function in versions 1.0 to 2.2.7. This makes it possible for authenticated attackers, with Subscriber-level access and above, to overwrite the plugin’s 'register' role setting to make new user registrations default to the administrator role, leading to an elevation of privileges to that of an administrator.
CVE-2024-57336 2026-04-15 6.5 Medium
Incorrect access control in M2Soft CROWNIX Report & ERS affected v7.x to v7.4.3.599 and v8.x to v8.0.3.79 allows unauthorized attackers to obtain Administrator account access.