Search Results (407534 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-53983 2026-04-15 5.4 Medium
The Backstage Scaffolder plugin Houses types and utilities for building scaffolder-related modules. A vulnerability is identified in Backstage Scaffolder template functionality where Server-Side Template Injection (SSTI) can be exploited to perform Git config injection. The vulnerability allows an attacker to capture privileged git tokens used by the Backstage Scaffolder plugin. With these tokens, unauthorized access to sensitive resources in git can be achieved. The impact is considered medium severity as the Backstage Threat Model recommends restricting access to adding and editing templates in the Backstage Catalog plugin. The issue has been resolved in versions `v0.4.12`, `v0.5.1` and `v0.6.1` of the `@backstage/plugin-scaffolder-node` package. Users are encouraged to upgrade to this version to mitigate the vulnerability. Users are advised to upgrade. Users unable to upgrade may ensure that templates do not change git config.
CVE-2024-54124 1 Clickstudios 1 Passwordstate 2026-04-15 8.8 High
In Click Studios Passwordstate before build 9920, there is a potential permission escalation on the edit folder screen.
CVE-2024-57177 2026-04-15 7.3 High
A host header injection vulnerability exists in the NPM package of perfood/couch-auth <= 0.21.2. By sending a specially crafted host header in the email change confirmation request, it is possible to trigger a SSTI which can be leveraged to run limited commands or leak server-side information
CVE-2025-8866 1 Yugabyte 1 Yugabytedb 2026-04-15 5.3 Medium
YugabyteDB Anywhere web server does not properly enforce authentication for the /metamaster/universe API endpoint. An unauthenticated attacker could exploit this flaw to obtain server networking configuration details, including private and public IP addresses and DNS records.
CVE-2025-0577 1 Redhat 1 Enterprise Linux 2026-04-15 4.8 Medium
An insufficient entropy vulnerability was found in glibc. The getrandom and arc4random family of functions may return predictable randomness if these functions are called again after the fork, which happens concurrently with a call to any of these functions.
CVE-2025-8415 1 Redhat 1 Cryostat 2026-04-15 5.9 Medium
A vulnerability was found in the Cryostat HTTP API. Cryostat's HTTP API binds to all network interfaces, allowing possible external visibility and access to the API port if Network Policies are disabled, allowing an unauthenticated, malicious attacker to jeopardize the environment.
CVE-2024-46961 1 Inshot.com 1 X Downloader 2026-04-15 8.1 High
The Inshot com.downloader.privatebrowser (aka Video Downloader - XDownloader) application through 1.3.5 for Android allows an attacker to execute arbitrary JavaScript code via the com.downloader.privatebrowser.activity.PrivateMainActivity component.
CVE-2024-46505 2026-04-15 9.1 Critical
Infoblox BloxOne v2.4 was discovered to contain a business logic flaw due to thick client vulnerabilities.
CVE-2025-8396 1 Temporal 1 Temporal 2026-04-15 N/A
Insufficiently specific bounds checking on authorization header could lead to denial of service in the Temporal server on all platforms due to excessive memory allocation.This issue affects all platforms and versions of OSS Server prior to 1.26.3, 1.27.3, and 1.28.1 (i.e., fixed in 1.26.3, 1.27.3, and 1.28.1 and later). Temporal Cloud services are not impacted.
CVE-2025-3755 2026-04-15 9.1 Critical
Improper Validation of Specified Index, Position, or Offset in Input vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU modules allows a remote unauthenticated attacker to read information in the product, to cause a Denial-of-Service (DoS) condition in MELSOFT connection, or to stop the operation of the CPU module (causing a DoS condtion on the CPU module), by sending specially crafted packets. The product is needed to reset for recovery.
CVE-2024-43663 2026-04-15 9.8 Critical
There are many buffer overflow vulnerabilities present in several CGI binaries of the charging station.This issue affects Iocharger firmware for AC model chargers beforeversion 24120701. Likelihood: High – Given the prevalence of these buffer overflows, and the clear error message of the web server, an attacker is very likely to be able to find these vulnerabilities. Impact: Low – Usually, overflowing one of these buffers just causes a segmentation fault of the CGI binary, which causes the web server to return a 502 Bad Gateway error. However the webserver itself is not affected, and no DoS can be achieved. Abusing these buffer overflows in a meaningful way requires highly technical knowledge, especially since ASLR also seems to be enabled on the charging station. However, a skilled attacker might be able to use one of these buffer overflows to obtain remote code execution. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The attack has a small impact on the availability of the device (VC:N/VI:N/VA:L). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, we do not expect  this vulnerability to have a safety impact. The attack can be automated (AU:Y).
CVE-2025-8284 1 Packet Power 2 Eg, Emx 2026-04-15 9.8 Critical
By default, the Packet Power Monitoring and Control Web Interface do not enforce authentication mechanisms. This vulnerability could allow unauthorized users to access and manipulate monitoring and control functions.
CVE-2024-45495 2026-04-15 4.3 Medium
MSA FieldServer Gateway 5.0.0 through 6.5.2 allows cross-origin WebSocket hijacking.
CVE-2024-43662 2026-04-15 N/A
The <redacted>.exe or <redacted>.exe CGI binary can be used to upload arbitrary files to /tmp/upload/ or /tmp/ respectively as any user, although the user interface for uploading files is only shown to the iocadmin user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – An attacker will need to have knowledge of this CGI binary, e.g. by finding it in firmware. Furthermore, the attacker will need a (low privilege) account to gain access to the <redacted>.exe or <redacted>.exe CGI binary and upload the file, or convince a user with such access to upload it. Impact: Low – The attacker can upload arbitrary files to /tmp/upload/ or /tmp/. However, the attacker is unable to access or use these files without other vulnerabilities. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). Artitrary files can be uploaded, be these files will not be in a location where they can influence confidentiality or availability and have a minimal impact on device integrity (VC:N/VI:L/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, we do not expect this vulnerability to have a safety impact. The attack can be automated (AU:Y).
CVE-2024-43660 2026-04-15 7.5 High
The CGI script <redacted>.sh can be used to download any file on the filesystem. This issue affects Iocharger firmware for AC model chargers beforeversion 24120701. Likelihood: High, but credentials required. Impact: Critical – The script can be used to download any file on the filesystem, including sensitive files such as /etc/shadow, the CGI script source code or binaries and configuration files. CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/S:P/AU:Y CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The confidentiality of all files of the devicd can be compromised (VC:H/VI:N/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, this attack in isolation does not have a safety impact. The attack can be automated (AU:Y).
CVE-2024-43659 2026-04-15 7.2 High
After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers. This issue affects Iocharger firmware for AC models before firmware version 25010801. The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models. Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using <redacted>.sh) to gain access to the <redacted>.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels. Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2025-53692 1 Sitecore 2 Experience Manager, Experience Platform 2026-04-15 7.1 High
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Sitecore Sitecore Experience Manager (XM), Sitecore Experience Platform (XP) allows Cross-Site Scripting (XSS).This issue affects Sitecore Experience Manager (XM): from 9.2 through 10.4; Experience Platform (XP): from 9.2 through 10.4.
CVE-2024-41930 2026-04-15 6.1 Medium
Cross-site scripting vulnerability exists in MF Teacher Performance Management System version 6. If this vulnerability is exploited, an arbitrary script may be executed on the web browser of the user who accessed the website using the product.
CVE-2024-43658 2026-04-15 N/A
Patch traversal, External Control of File Name or Path vulnerability in Iocharger Home allows deletion of arbitrary files This issue affects Iocharger firmware for AC model before firmware version 25010801. Likelihood: High, but requires authentication Impact: Critical – The vulnerability can be used to delete any file on the charging station, severely impacting the integrity of the charging station. Furthermore, the vulnerability could be used to delete binaries required for the functioning of the charging station, severely impacting the availability of the charging station. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads compromised of the integrity and availability of the device (VVC:N/VI:H/VA:H), with no effect on subsequent systems (SC:N/SI:N/SA:N). We do not forsee a safety impact (S:N). This attack can be automated (AU:Y).
CVE-2024-43657 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).