| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| SQL Injection vulnerability in the default configuration of the Logitime WebClock application <= 5.43.0 allows an unauthenticated user to run arbitrary code on the backend database server. |
| Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in icc0rz H5P h5p allows Stored XSS.This issue affects H5P: from n/a through <= 1.16.0. |
| An allocation-size-too-big bug in the component /imagebuf.cpp of OpenImageIO v3.1.0.0dev may cause a Denial of Service (DoS) when the program to requests to allocate too much space. |
| There is a vulnerability in the Supermicro BMC web function at Supermicro MBD-X13SEDW-F. After logging into the BMC Web server, an attacker can use a specially crafted payload to trigger the Stack buffer overflow vulnerability. |
| Heap buffer overflow in the server site handshake implementation in Real Time Logic LLC's SharkSSL version (from 05/05/24) commit 64808a5e12c83b38f85c943dee0112e428dc2a43 allows a remote attacker to trigger a Denial-of-Service via a malformed Client-Hello message. |
| A flaw was found in Red Hat Satellite (Foreman component). This vulnerability allows an authenticated user with edit_settings permissions to achieve arbitrary command execution on the underlying operating system via insufficient server-side validation of command whitelisting. |
| A disclosure of sensitive information flaw was found in foreman via the GraphQL API. If the introspection feature is enabled, it is possible for attackers to retrieve sensitive admin authentication keys which could result in a compromise of the entire product's API. |
| BigFix Patch Download Plug-ins are affected by an insecure protocol support. The application can allow improper handling of SSL certificates validation. |
| A mismatch caused by client-triggered server-sent stream resets between HTTP/2 specifications and the internal architectures of some HTTP/2 implementations may result in excessive server resource consumption leading to denial-of-service (DoS). By opening streams and then rapidly triggering the server to reset them—using malformed frames or flow control errors—an attacker can exploit incorrect stream accounting. Streams reset by the server are considered closed at the protocol level, even though backend processing continues. This allows a client to cause the server to handle an unbounded number of concurrent streams on a single connection. This CVE will be updated as affected product details are released. |
| Grafana is an open-source platform for monitoring and observability. The Infinity datasource plugin, maintained by Grafana Labs, allows visualizing data from JSON, CSV, XML, GraphQL, and HTML endpoints.
If the plugin was configured to allow only certain URLs, an attacker could bypass this restriction using a specially crafted URL. This vulnerability is fixed in version 3.4.1. |
| Improper neutralization of newlines in pg_dump in PostgreSQL allows a user of the origin server to inject arbitrary code for restore-time execution as the client operating system account running psql to restore the dump, via psql meta-commands inside a purpose-crafted object name. The same attacks can achieve SQL injection as a superuser of the restore target server. pg_dumpall, pg_restore, and pg_upgrade are also affected. Versions before PostgreSQL 17.6, 16.10, 15.14, 14.19, and 13.22 are affected. Versions before 11.20 are unaffected. CVE-2012-0868 had fixed this class of problem, but version 11.20 reintroduced it. |
| Untrusted data inclusion in pg_dump in PostgreSQL allows a malicious superuser of the origin server to inject arbitrary code for restore-time execution as the client operating system account running psql to restore the dump, via psql meta-commands. pg_dumpall is also affected. pg_restore is affected when used to generate a plain-format dump. This is similar to MySQL CVE-2024-21096. Versions before PostgreSQL 17.6, 16.10, 15.14, 14.19, and 13.22 are affected. |
| An integer overflow in the SMU could allow a privileged attacker to potentially write memory beyond the end of the reserved dRAM area resulting in loss of integrity or availability. |
| Improper input validation in the SMM handler may allow a privileged attacker to overwrite SMRAM, potentially leading to arbitrary code execution. |
| (conda) Constructor is a tool which allows constructing an installer for a collection of conda packages. Prior to version 3.11.3, shell installer scripts process the installation prefix (user_prefix) using an eval statement, which executes unsanitized user input as shell code. Although the script runs with user privileges (not root), an attacker could exploit this by injecting arbitrary commands through a malicious path during installation. Exploitation requires explicit user action. This issue has been patched in version 3.11.3. |
| Improper input validation in the SMM handler may allow a privileged attacker to overwrite SMRAM, potentially leading to arbitrary code execution. |
| PostgreSQL optimizer statistics allow a user to read sampled data within a view that the user cannot access. Separately, statistics allow a user to read sampled data that a row security policy intended to hide. PostgreSQL maintains statistics for tables by sampling data available in columns; this data is consulted during the query planning process. Prior to this release, a user could craft a leaky operator that bypassed view access control lists (ACLs) and bypassed row security policies in partitioning or table inheritance hierarchies. Reachable statistics data notably included histograms and most-common-values lists. CVE-2017-7484 and CVE-2019-10130 intended to close this class of vulnerability, but this gap remained. Versions before PostgreSQL 17.6, 16.10, 15.14, 14.19, and 13.22 are affected. |
| A vulnerability, which was classified as critical, has been found in agno-agi agno up to 1.7.5. This issue affects the function MCPTools/MultiMCPTools in the library libs/agno/agno/tools/mcp.py of the component Model Context Protocol Handler. The manipulation of the argument command leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Information Disclosure in API in Replicated Replicated Classic versions prior to 2.53.1 on all platforms allows authenticated users with Admin Console access to retrieve sensitive data, including application secrets, via accessing container definitions with environment variables through the Admin Console API on port 8800.
This CVE was originally reserved in 2021 and later publicly disclosed by Replicated on their website on 21 October 2021. However, it mistakenly remained in the Reserved But Public (RBP) status with the CVE Numbering Authority (CNA). Please note that this product reached its end of life on 31 December 2024. Publishing this CVE with the CNA was required to comply with CNA rules, despite the fact that the issue was disclosed and fixed four years ago, and the affected product is no longer supported as of 2024.
Summary of VulnerabilityThis advisory discloses a low severity security vulnerability in the versions of Replicated Classic listed above (“Affected Replicated Classic Versions”)
DescriptionReplicated Classic versions prior to 2.53.1 have an authenticated API from the Replicated Admin Console that may expose sensitive data including application secrets, depending on how the application manifests are written. A user with valid credentials and access to the Admin Console port (8800) on the Replicated Classic server can retrieve container definitions including environment variables which may contain passwords and other secrets depending on how the application is configured.
This data is shared over authenticated sessions to the Admin Console only, and was never displayed or used in the application processing. To remediate this issue, we removed the sensitive data from the API, sending only the data to the Admin Console that was needed.
TimelineThis issue was discovered during a security review on 16 September 2021.
Patched versions were released on 23 September 2021.
This advisory was published on 21 October 2021.
The CVE Numbering Authority (CNA) notified Replicated on 23 January 2025 that the CVE was still in Reserved But Public (RBP) status. Upon discovering the oversight in updating the status to published with the CNA, Replicated submitted the updated report on the same day, 23 January 2025. |
| Use of an uninitialized variable in the ASP could allow an attacker to access leftover data from a trusted execution environment (TEE) driver, potentially leading to loss of confidentiality. |