| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An improper link resolution vulnerability in the Palo Alto Networks Cortex XDR agent on Windows devices allows a local attacker to read files on the system with elevated privileges when generating a tech support file. |
| Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Drupal Ignition Error Pages allows Cross-Site Scripting (XSS).This issue affects Ignition Error Pages: from 0.0.0 before 1.0.4. |
| Missing Authorization vulnerability in Drupal AI (Artificial Intelligence) allows Forceful Browsing.This issue affects AI (Artificial Intelligence): from 0.0.0 before 1.0.3. |
| Improper Input Validation vulnerability exists in the Hitachi Energy MicroSCADA X SYS600's ICCP stack during the ICCP communication establishment causes a denial-of-service when ICCP of SYS600 is request to forward any data item updates with timestamps too distant in the future to any remote ICCP system. By default, ICCP is not configured and not enabled. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10.2 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:* |
| Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the SYS600 product. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:* |
| Cross-Site Request Forgery (CSRF) vulnerability in Drupal AI (Artificial Intelligence) allows Cross Site Request Forgery.This issue affects AI (Artificial Intelligence): from 1.0.0 before 1.0.2. |
| Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. The configuration file can only be accessed by an administrator access. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:* |
| Missing Authorization vulnerability in Post SMTP Post SMTP Mailer/Email Log.This issue affects Post SMTP Mailer/Email Log: from n/a through 2.8.6. |
| The POST SMTP Mailer WordPress plugin before 2.5.7 does not have proper CSRF checks in some AJAX actions, which could allow attackers to make logged in users with the manage_postman_smtp capability resend an email to an arbitrary address (for example a password reset email could be resent to an attacker controlled email, and allow them to take over an account). |
| The POST SMTP Mailer WordPress plugin before 2.7.1 does not escape email message content before displaying it in the backend, allowing an unauthenticated attacker to perform XSS attacks against highly privileged users. |
| Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected connection is left open. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:* |
| A missing authorization in Fortinet FortiManager versions 7.2.0 through 7.2.1, and versions 7.0.0 through 7.0.7 may allow an authenticated attacker to overwrite global threat feeds via crafted update requests. |
| FreeScout is a free self-hosted help desk and shared mailbox. Prior to version 1.8.180, the application is vulnerable to Cross-Site Scripting (XSS) attacks due to incorrect input validation and sanitization of user-input data when an authenticated user updates the profile of an arbitrary customer. This issue has been patched in version 1.8.180. |
| A vulnerability, which was classified as critical, has been found in SourceCodester Health Center Patient Record Management System 1.0. Affected by this issue is some unknown functionality of the file /admin/admin.php. The manipulation of the argument Username leads to sql injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. |
| schema_element defeats protective search_path changes; It was found that certain database calls in PostgreSQL could permit an authed attacker with elevated database-level privileges to execute arbitrary code. |
| In Apache Linkis <= 1.5.0,
Privilege Escalation in Basic management services where the attacking user is
a trusted account
allows access to Linkis's Token information. Users are advised to upgrade to version 1.6.0, which fixes this issue. |
| Apache Airflow versions before 2.10.1 have a vulnerability that allows DAG authors to add local settings to the DAG folder and get it executed by the scheduler, where the scheduler is not supposed to execute code submitted by the DAG author.
Users are advised to upgrade to version 2.10.1 or later, which has fixed the vulnerability. |
| Example DAG: example_inlet_event_extra.py shipped with Apache Airflow version 2.10.0 has a vulnerability that allows an authenticated attacker with only DAG trigger permission to execute arbitrary commands. If you used that example as the base of your DAGs - please review if you have not copied the dangerous example; see https://github.com/apache/airflow/pull/41873 for more information. We recommend against exposing the example DAGs in your deployment. If you must expose the example DAGs, upgrade Airflow to version 2.10.1 or later. |
| Apache Airflow versions before 2.10.3 contain a vulnerability that could expose sensitive configuration variables in task logs. This vulnerability allows DAG authors to unintentionally or intentionally log sensitive configuration variables. Unauthorized users could access these logs, potentially exposing critical data that could be exploited to compromise the security of the Airflow deployment. In version 2.10.3, secrets are now masked in task logs to prevent sensitive configuration variables from being exposed in the logging output. Users should upgrade to Airflow 2.10.3 or the latest version to eliminate this vulnerability. If you suspect that DAG authors could have logged the secret values to the logs and that your logs are not additionally protected, it is also recommended that you update those secrets. |
| Insufficient Session Expiration vulnerability in Apache Airflow Fab Provider.
This issue affects Apache Airflow Fab Provider: before 1.5.2.
When user password has been changed with admin CLI, the sessions for that user have not been cleared, leading to insufficient session expiration, thus logged users could continue to be logged in even after the password was changed. This only happened when the password was changed with CLI. The problem does not happen in case change was done with webserver thus this is different from CVE-2023-40273 https://github.com/advisories/GHSA-pm87-24wq-r8w9 which was addressed in Apache-Airflow 2.7.0
Users are recommended to upgrade to version 1.5.2, which fixes the issue. |