| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The decrypted configuration file contains the password in cleartext
which is used to configure WINSelect. It can be used to remove the
existing restrictions and disable WINSelect entirely. |
| This vulnerability exists in ZKTeco WL20 due to storage of admin and user credentials without encryption in the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and reverse engineer the binary data to access the unencrypted credentials stored in the firmware of targeted device. |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions), SIPROTEC 5 6MD89 (CP300) (All versions), SIPROTEC 5 6MU85 (CP300) (All versions), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions), SIPROTEC 5 7SJ81 (CP100) (All versions), SIPROTEC 5 7SJ81 (CP150) (All versions), SIPROTEC 5 7SJ82 (CP100) (All versions), SIPROTEC 5 7SJ82 (CP150) (All versions), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions), SIPROTEC 5 7SK82 (CP100) (All versions), SIPROTEC 5 7SK82 (CP150) (All versions), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions), SIPROTEC 5 7ST86 (CP300) (All versions), SIPROTEC 5 7SX82 (CP150) (All versions), SIPROTEC 5 7SX85 (CP300) (All versions), SIPROTEC 5 7SY82 (CP150) (All versions), SIPROTEC 5 7UM85 (CP300) (All versions), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions), SIPROTEC 5 7VE85 (CP300) (All versions), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions), SIPROTEC 5 7VU85 (CP300) (All versions), SIPROTEC 5 Compact 7SX800 (CP050) (All versions). Affected devices do not encrypt certain data within the on-board flash storage on their PCB. This could allow an attacker with physical access to read the entire filesystem of the device. |
| A security issue was discovered within the legacy Ansible playbook component of Verve Asset Manager, caused by plaintext secrets incorrectly stored when a playbook is running. This component has been retired and has been optional since the 1.36 release in 2024. |
| A local user may find a configuration file on the client workstation with unencrypted sensitive data. This allows an attacker to impersonate the device or prevent the device from accessing the cloud portal which leads to a DoS. |
| A local, low-privileged attacker can learn the password of the connected controller in PLC Designer V4 due to an incorrect implementation that results in the password being displayed in plain text under special conditions. |
| next-forge is a Next.js project boilerplate for modern web application. The BASEHUB_TOKEN commited in apps/web/.env.example. Users should avoid use of this token and should remove any access it may have in their systems. |
| Infoblox BloxOne v2.4 was discovered to contain a business logic flaw due to thick client vulnerabilities. |
| With physical access to the device and enough time an attacker can desolder the flash memory, modify it and then reinstall it because of missing encryption. Thus, essential files, such as "/etc/passwd", as well as stored certificates, cryptographic keys, stored PINs and so on can be modified and read, in order to gain SSH root access on the Linux-based K7 model. On the Windows CE based K5 model, the password for the Access Manager can additionally be read in plain text from the stored SQLite database. |
| CWE-312: Cleartext Storage of Sensitive Information vulnerability exists that exposes test
credentials in the firmware binary |
| An issue in the SMTP Email Settings of AVTECH Room Alert 4E v4.4.0 allows attackers to gain access to credentials in plaintext via a passback attack. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. |
| Hathway Skyworth Router CM5100-511 v4.1.1.24 was discovered to store sensitive information about USB and Wifi connected devices in plaintext. |
| Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files.
This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025 |
| The data stored in Be-Tech Mifare Classic card is stored in cleartext. An attacker having access to a Be-Tech hotel guest Mifare Classic card can create a master key card that unlocks all the locks in the building.
This issue affects all Be-Tech Mifare Classic card systems. To fix the vulnerability, it is necessary to replace the software, encoder, cards, and PCBs in the locks. |
| An issue was discovered in Teledyne FLIR M300 2.00-19. User account passwords are encrypted locally, and can be decrypted to cleartext passwords using the utility umSetup. This utility requires root permissions to execute. |
| This vulnerability exists in TP-Link Tapo H200 V1 IoT Smart Hub due to storage of Wi-Fi credentials in plain text within the device firmware. An attacker with physical access could exploit this by extracting the firmware and analyzing the binary data to obtain the Wi-Fi credentials stored on the vulnerable device. |
| Unauthorized disclosure of sensitive data: Any user with `GET` or `LIST` permissions on `BundleDeployment` resources could retrieve Helm values containing credentials or other secrets. |
| An issue in H3C switch h3c-S1526 allows a remote attacker to obtain sensitive information via the S1526.cfg component. |
| Cleartext Storage of Sensitive Information vulnerability in OpenText™ Vertica allows Retrieve Embedded Sensitive Data.
The vulnerability could read Vertica agent plaintext apikey.This issue affects Vertica versions: 23.X, 24.X, 25.X. |
| A vulnerability has been identified in OPUPI0 AMQP/MQTT (All versions < V5.30). The affected devices stores MQTT client passwords without sufficient protection on the devices. An attacker with remote shell access or physical access could retrieve the credentials leading to confidentiality loss. |