Search

Search Results (409297 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-21821 1 Linux 1 Linux Kernel 2026-01-02 5.5 Medium
In the Linux kernel, the following vulnerability has been resolved: fbdev: omap: use threaded IRQ for LCD DMA When using touchscreen and framebuffer, Nokia 770 crashes easily with: BUG: scheduling while atomic: irq/144-ads7846/82/0x00010000 Modules linked in: usb_f_ecm g_ether usb_f_rndis u_ether libcomposite configfs omap_udc ohci_omap ohci_hcd CPU: 0 UID: 0 PID: 82 Comm: irq/144-ads7846 Not tainted 6.12.7-770 #2 Hardware name: Nokia 770 Call trace: unwind_backtrace from show_stack+0x10/0x14 show_stack from dump_stack_lvl+0x54/0x5c dump_stack_lvl from __schedule_bug+0x50/0x70 __schedule_bug from __schedule+0x4d4/0x5bc __schedule from schedule+0x34/0xa0 schedule from schedule_preempt_disabled+0xc/0x10 schedule_preempt_disabled from __mutex_lock.constprop.0+0x218/0x3b4 __mutex_lock.constprop.0 from clk_prepare_lock+0x38/0xe4 clk_prepare_lock from clk_set_rate+0x18/0x154 clk_set_rate from sossi_read_data+0x4c/0x168 sossi_read_data from hwa742_read_reg+0x5c/0x8c hwa742_read_reg from send_frame_handler+0xfc/0x300 send_frame_handler from process_pending_requests+0x74/0xd0 process_pending_requests from lcd_dma_irq_handler+0x50/0x74 lcd_dma_irq_handler from __handle_irq_event_percpu+0x44/0x130 __handle_irq_event_percpu from handle_irq_event+0x28/0x68 handle_irq_event from handle_level_irq+0x9c/0x170 handle_level_irq from generic_handle_domain_irq+0x2c/0x3c generic_handle_domain_irq from omap1_handle_irq+0x40/0x8c omap1_handle_irq from generic_handle_arch_irq+0x28/0x3c generic_handle_arch_irq from call_with_stack+0x1c/0x24 call_with_stack from __irq_svc+0x94/0xa8 Exception stack(0xc5255da0 to 0xc5255de8) 5da0: 00000001 c22fc620 00000000 00000000 c08384a8 c106fc00 00000000 c240c248 5dc0: c113a600 c3f6ec30 00000001 00000000 c22fc620 c5255df0 c22fc620 c0279a94 5de0: 60000013 ffffffff __irq_svc from clk_prepare_lock+0x4c/0xe4 clk_prepare_lock from clk_get_rate+0x10/0x74 clk_get_rate from uwire_setup_transfer+0x40/0x180 uwire_setup_transfer from spi_bitbang_transfer_one+0x2c/0x9c spi_bitbang_transfer_one from spi_transfer_one_message+0x2d0/0x664 spi_transfer_one_message from __spi_pump_transfer_message+0x29c/0x498 __spi_pump_transfer_message from __spi_sync+0x1f8/0x2e8 __spi_sync from spi_sync+0x24/0x40 spi_sync from ads7846_halfd_read_state+0x5c/0x1c0 ads7846_halfd_read_state from ads7846_irq+0x58/0x348 ads7846_irq from irq_thread_fn+0x1c/0x78 irq_thread_fn from irq_thread+0x120/0x228 irq_thread from kthread+0xc8/0xe8 kthread from ret_from_fork+0x14/0x28 As a quick fix, switch to a threaded IRQ which provides a stable system.
CVE-2025-21690 1 Linux 1 Linux Kernel 2026-01-02 5.5 Medium
In the Linux kernel, the following vulnerability has been resolved: scsi: storvsc: Ratelimit warning logs to prevent VM denial of service If there's a persistent error in the hypervisor, the SCSI warning for failed I/O can flood the kernel log and max out CPU utilization, preventing troubleshooting from the VM side. Ratelimit the warning so it doesn't DoS the VM.
CVE-2025-53398 1 Portrait 2 Dell Color Management, Dell Color Management Application 2026-01-02 7.8 High
The Portrait Dell Color Management application 3.3.8 for Dell monitors has Insecure Permissions,
CVE-2025-53618 2 Grassroots Dicom Project, Malaterre 2 Grassroots Dicom, Grassroots Dicom 2026-01-02 7.4 High
An out-of-bounds read vulnerability exists in the JPEGBITSCodec::InternalCode functionality of Grassroot DICOM 3.024. A specially crafted DICOM file can lead to an information leak. An attacker can provide a malicious file to trigger this vulnerability.The function `grayscale_convert` is called based of the value of the malicious DICOM file specifying the intended interpretation of the image pixel data
CVE-2025-53619 2 Grassroots Dicom Project, Malaterre 2 Grassroots Dicom, Grassroots Dicom 2026-01-02 7.4 High
An out-of-bounds read vulnerability exists in the JPEGBITSCodec::InternalCode functionality of Grassroot DICOM 3.024. A specially crafted DICOM file can lead to an information leak. An attacker can provide a malicious file to trigger this vulnerability.The function `null_convert` is called based of the value of the malicious DICOM file specifying the intended interpretation of the image pixel data
CVE-2025-67015 1 Comtech 4 Cdm-625, Cdm-625 Firmware, Cdm-625a and 1 more 2026-01-02 7.5 High
Incorrect access control in Comtech EF Data CDM-625 / CDM-625A Advanced Satellite Modem with firmware v2.5.1 allows attackers to change the Administrator password and escalate privileges via sending a crafted POST request to /Forms/admin_access_1.
CVE-2025-53919 1 Portrait 2 Dell Color Management, Dell Color Management Application 2026-01-02 7.8 High
An issue was discovered in the Portrait Dell Color Management application through 3.3.008 for Dell monitors, It creates a temporary folder, with weak permissions, during installation and uninstallation. A low-privileged attacker with local access could potentially exploit this, leading to elevation of privileges.
CVE-2025-53922 1 Galette 1 Galette 2026-01-02 4.9 Medium
Galette is a membership management web application for non profit organizations. Starting in version 1.1.4 and prior to version 1.2.0, a user who is logged in as group manager may bypass intended restrictions on Contributions and Transactions. Version 1.2.0 fixes the issue.
CVE-2019-17667 1 Comtech 2 H8 Heights Remote Gateway, H8 Heights Remote Gateway Firmware 2026-01-02 5.4 Medium
Comtech H8 Heights Remote Gateway 2.5.1 devices allow XSS and HTML injection via the Site Name (aka SiteName) field.
CVE-2020-5179 1 Comtech 2 Stampede Fx-1010, Stampede Fx-1010 Firmware 2026-01-02 7.2 High
Comtech Stampede FX-1010 7.4.3 devices allow remote authenticated administrators to execute arbitrary OS commands by navigating to the Diagnostics Ping page and entering shell metacharacters in the Target IP address field. (In some cases, authentication can be achieved with the comtech password for the comtech account.)
CVE-2020-7242 1 Comtech 2 Stampede Fx-1010, Stampede Fx-1010 Firmware 2026-01-02 7.2 High
Comtech Stampede FX-1010 7.4.3 devices allow remote authenticated administrators to achieve remote code execution by navigating to the Diagnostics Trace Route page and entering shell metacharacters in the Target IP address field. (In some cases, authentication can be achieved with the comtech password for the comtech account.)
CVE-2020-7243 1 Comtech 2 Stampede Fx-1010, Stampede Fx-1010 Firmware 2026-01-02 7.2 High
Comtech Stampede FX-1010 7.4.3 devices allow remote authenticated administrators to achieve remote code execution by navigating to the Fetch URL page and entering shell metacharacters in the URL field. (In some cases, authentication can be achieved with the comtech password for the comtech account.)
CVE-2020-7244 1 Comtech 2 Stampede Fx-1010, Stampede Fx-1010 Firmware 2026-01-02 7.2 High
Comtech Stampede FX-1010 7.4.3 devices allow remote authenticated administrators to achieve remote code execution by navigating to the Poll Routes page and entering shell metacharacters in the Router IP Address field. (In some cases, authentication can be achieved with the comtech password for the comtech account.)
CVE-2025-50399 1 Fastcom 2 Fac1200r, Fac1200r Firmware 2026-01-02 9.8 Critical
FAST FAC1200R F400_FAC1200R_Q is vulnerable to Buffer Overflow in the function sub_80435780 via the parameter password.
CVE-2025-50402 1 Fastcom 2 Fac1200r, Fac1200r Firmware 2026-01-02 9.8 Critical
FAST FAC1200R F400_FAC1200R_Q is vulnerable to Buffer Overflow in the function sub_80435780 via the parameter string fac_password.
CVE-2025-50526 1 Netgear 2 Ex8000, Ex8000 Firmware 2026-01-02 9.8 Critical
Netgear EX8000 V1.0.0.126 was discovered to contain a command injection vulnerability via the switch_status function.
CVE-2025-50681 1 Pali 1 Igmpproxy 2026-01-02 7.5 High
igmpproxy 0.4 before commit 2b30c36 allows remote attackers to cause a denial of service (application crash) via a crafted IGMPv3 membership report packet with a malicious source address. Due to insufficient validation in the `recv_igmp()` function in src/igmpproxy.c, an invalid group record type can trigger a NULL pointer dereference when logging the address using `inet_fmtsrc()`. This vulnerability can be exploited by sending malformed multicast traffic to a host running igmpproxy, leading to a crash. igmpproxy is used in various embedded networking environments and consumer-grade IoT devices (such as home routers and media gateways) to handle multicast traffic for IPTV and other streaming services. Affected devices that rely on unpatched versions of igmpproxy may be vulnerable to remote denial-of-service attacks across a LAN .
CVE-2025-51962 1 Microstudio 1 Microstudio 2026-01-02 6.1 Medium
A HTML Injection vulnerability in the comment section of the project page in MicroStudio 24.01.29 allows remote attackers to inject arbitrary web script or HTML via the text parameter of add_project_comment function.
CVE-2025-52196 1 Ctera 2 Ctera, Portal 2026-01-02 7.5 High
Server-Side Request Forgery (SSRF) vulnerability in Ctera Portal 8.1.x (8.1.1417.24) allows remote attackers to induce the server to make arbitrary HTTP requests via a crafted HTML file containing an iframe.
CVE-2025-52493 1 Pagerduty 2 Runbook, Runbook Automation 2026-01-02 6.5 Medium
PagerDuty Runbook through 2025-06-12 exposes stored secrets directly in the webpage DOM at the configuration page. Although these secrets appear masked as password fields, the actual secret values are present in the page source and can be revealed by simply modifying the input field type from "password" to "text" using browser developer tools. This vulnerability is exploitable by administrative users who have access to the configuration page.