| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Locally installed application can bypass the permission check and perform system operations that require permission. |
| Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down. |
| The vulnerability allows attackers access to the root account without having to authenticate. Specifically, if the device is configured with the IP address of 10.10.10.10, the root user is automatically logged in. |
| A vulnerability allows unauthorized access to functionality inadequately constrained by ACLs. Attackers may exploit this to unauthenticated execute commands potentially leading to unauthorized data manipulation, access to privileged functions, or even the execution of arbitrary code. |
| A potential security vulnerability has been identified in HP Sure Start’s protection of the Intel Flash Descriptor in certain HP PC products, which might allow security bypass, arbitrary code execution, loss of integrity or confidentiality, or denial of service. HP is releasing BIOS updates to mitigate the potential vulnerability. |
| Authorization bypass vulnerability in Hitachi Infrastructure Analytics Advisor (Data Center Analytics component) and Hitachi Ops Center Analyzer (Hitachi Ops Center Analyzer detail view component).This issue affects Hitachi Infrastructure Analytics Advisor:; Hitachi Ops Center Analyzer: from 10.0.0-00 before 11.0.5-00. |
| A device takeover vulnerability exists in the Rockwell Automation Power Monitor 1000. This vulnerability allows configuration of a new Policyholder user without any authentication via API. Policyholder user is the most privileged user that can perform edit operations, creating admin users and performing factory reset. |
| The passwordless login mechanism in CGFIDO from Changing Information Technology has an Authentication Bypass vulnerability, allowing remote attackers with regular privileges to send a crafted request to switch to the identity of any user, including administrators. |
| The health module has insufficient restrictions on loading URLs, which may lead to some information leakage. |
| The MinigameCenter module has insufficient restrictions on loading URLs, which may lead to some information leakage. |
| An issue in Casa Systems NTC-221 version 2.0.99.0 and before allows a remote attacker to execute arbitrary code via a crafted payload to the /www/cgi-bin/nas.cgi component. |
| Toshiba printers provides API without authentication for internal access. A local attacker can bypass authentication in applications, providing administrative access. As for the affected products/models/versions, see the reference URL. |
| Missing authentication for critical function vulnerability exists in ID Link Manager and FUJITSU Software TIME CREATOR. If this vulnerability is exploited, sensitive information may be obtained and/or the information stored in the database may be altered by a remote authenticated attacker. |
| Admin authentication can be bypassed with some specific invalid credentials, which allows logging in with an administrative privilege. Sharp Corporation states the telnet feature is implemented on older models only, and is planning to provide the firmware update to remove the feature. As for the details of affected product names, model numbers, and versions, refer to the information provided by the respective vendors listed under [References]. |
| An unauthenticated remote attacker may use a missing authentication for critical function vulnerability to reboot or erase the affected devices resulting in data loss and/or a DoS. |
| An unauthenticated remote attacker may use the devices traffic capture without authentication to grab plaintext administrative credentials. |
| Swissphone DiCal-RED 4009 devices allow a remote attacker to gain a root shell via TELNET without authentication. |
| The vulnerability allows an attacker to bypass the authentication requirements for a specific PAM endpoint. |
| PrivateBin is an online pastebin where the server has zero knowledge of pasted data. In v1.5, PrivateBin introduced the YOURLS server-side proxy. The idea was to allow using the YOURLs URL shortener without running the YOURLs instance without authentication and/or exposing the authentication token to the public, allowing anyone to shorten any URL. With the proxy mechanism, anyone can shorten any URL pointing to the configured PrivateBin instance. The vulnerability allowed other URLs to be shortened, as long as they contain the PrivateBin instance, defeating the limit imposed by the proxy. This vulnerability is fixed in 1.7.4. |
| A vulnerability in Kaiten version 57.131.12 and earlier allows attackers to bypass the PIN code authentication mechanism. The application requires users to input a 6-digit PIN code sent to their email for authorization after entering their login credentials. However, the request limiting mechanism can be easily bypassed, enabling attackers to perform a brute force attack to guess the correct PIN and gain unauthorized access to the application. |