Project Subscriptions
No data.
No advisories yet.
Solution
Upgrade to P-Net 1.0.4 or later.
Workaround
Build P-Net with PNET_OPTION_MC_CR disabled. Multicast communication relations are not supported by P-Net, and a Connect request with MCR blocks is then rejected.
Fri, 13 Nov 2026 13:30:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Description | P-Net before 1.0.4 does not check the number of MCR request blocks in a Connect request against the number of multicast communication relations that an Application Relationship has room for (PNET_MAX_MC_CR, 1 by default). Each further block is written past the end of the array, into the rest of the Application Relationship and, with more blocks, into the following one. The written data comes from the request. No established Application Relationship is needed, and the attacker requires ADJACENT network access. Builds with PNET_OPTION_MC_CR disabled are not affected. | |
| Title | Out-of-bounds write with too many MCR blocks in a Connect request | |
| Weaknesses | CWE-787 | |
| References |
| |
| Metrics |
cvssV4_0
|
Projects
Sign in to view the affected projects.
Status: PUBLISHED
Assigner: rt-labs
Published:
Updated: 2026-11-13T13:24:43.878Z
Reserved: 2026-11-12T15:30:49.638Z
Link: CVE-2026-127122
No data.
Status : Deferred
Published: 2026-11-13T14:17:54.500
Modified: 2026-11-13T14:17:54.657
Link: CVE-2026-127122
No data.
OpenCVE Enrichment
No data.