Export limit exceeded: 43617 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Export limit exceeded: 43617 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Export limit exceeded: 43617 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (43617 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-35963 | 2 Intel, Microsoft | 4 Proset, Proset/wireless, Proset/wireless Software and 1 more | 2026-04-15 | 7.4 High |
| Insufficient control flow management for some Intel(R) PROSet/Wireless WiFi Software for Windows before version 23.160 within Ring 2: Device Drivers may allow a denial of service. Unprivileged software adversary with an unauthenticated user combined with a low complexity attack may enable denial of service. This result may potentially occur via adjacent access when attack requirements are not present without special internal knowledge and requires no user interaction. The potential vulnerability may impact the confidentiality (none), integrity (none) and availability (high) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (high) impacts. | ||||
| CVE-2025-35967 | 2 Intel, Microsoft | 4 Proset, Proset/wireless, Proset/wireless Software and 1 more | 2026-04-15 | 7.4 High |
| Out-of-bounds read for some Intel(R) PROSet/Wireless WiFi Software for Windows before version 23.160 within Ring 2: Device Drivers may allow a denial of service. Unprivileged software adversary with an unauthenticated user combined with a low complexity attack may enable denial of service. This result may potentially occur via adjacent access when attack requirements are present without special internal knowledge and requires no user interaction. The potential vulnerability may impact the confidentiality (none), integrity (none) and availability (high) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (high) impacts. | ||||
| CVE-2025-35968 | 1 Intel | 1 Slim Bootloader | 2026-04-15 | 6.4 Medium |
| Protection mechanism failure in the UEFI firmware for the Slim Bootloader within firmware may allow an escalation of privilege. Startup code and smm adversary with a privileged user combined with a high complexity attack may enable escalation of privilege. This result may potentially occur via local access when attack requirements are present without special internal knowledge and requires no user interaction. The potential vulnerability may impact the confidentiality (high), integrity (high) and availability (high) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (none) impacts. | ||||
| CVE-2025-35971 | 2 Intel, Microsoft | 4 Proset, Proset/wireless, Proset/wireless Software and 1 more | 2026-04-15 | 8.2 High |
| Out-of-bounds write for some Intel(R) PROSet/Wireless WiFi Software for Windows before version 23.160 within Ring 2: Device Drivers may allow a denial of service. Unprivileged software adversary with an unauthenticated user combined with a low complexity attack may enable denial of service. This result may potentially occur via adjacent access when attack requirements are not present without special internal knowledge and requires no user interaction. The potential vulnerability may impact the confidentiality (none), integrity (low) and availability (high) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (high) impacts. | ||||
| CVE-2025-35972 | 1 Intel | 1 Mpi Library | 2026-04-15 | 6.7 Medium |
| Uncontrolled search path for the Intel MPI Library before version 2021.16 within Ring 3: User Applications may allow an escalation of privilege. Unprivileged software adversary with an authenticated user combined with a high complexity attack may enable escalation of privilege. This result may potentially occur via local access when attack requirements are present without special internal knowledge and requires active user interaction. The potential vulnerability may impact the confidentiality (high), integrity (high) and availability (high) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (none) impacts. | ||||
| CVE-2025-37103 | 2026-04-15 | 9.8 Critical | ||
| Hard-coded login credentials were found in HPE Networking Instant On Access Points, allowing anyone with knowledge of it to bypass normal device authentication. Successful exploitation could allow a remote attacker to gain administrative access to the system. | ||||
| CVE-2025-3717 | 1 Grafana | 1 Grafana | 2026-04-15 | N/A |
| When using the Grafana Snowflake Datasource Plugin, if Oauth passthrough is enabled on the datasource, and multiple users are using the same datasource at the same time on a single Grafana instance, it could result in the wrong user identifier being used, and information for which the viewer is not authorized being returned. This issue affects Grafana Snowflake Datasource Plugin: from 1.5.0 before 1.14.1. | ||||
| CVE-2025-37730 | 1 Elastic | 1 Logstash | 2026-04-15 | 6.5 Medium |
| Improper certificate validation in Logstash's TCP output could lead to a man-in-the-middle (MitM) attack in “client” mode, as hostname verification in TCP output was not being performed when the ssl_verification_mode => full was set. | ||||
| CVE-2025-4041 | 2026-04-15 | N/A | ||
| In Optigo Networks ONS NC600 versions 4.2.1-084 through 4.7.2-330, an attacker could connect with the device's ssh server and utilize the system's components to perform OS command executions. | ||||
| CVE-2025-40744 | 1 Siemens | 1 Solid Edge Se2025 | 2026-04-15 | 7.5 High |
| A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 11). Affected applications do not properly validate client certificates to connect to License Service endpoint. This could allow an unauthenticated remote attacker to perform man in the middle attacks. | ||||
| CVE-2025-40760 | 1 Siemens | 1 Altair Grid Engine | 2026-04-15 | 5.5 Medium |
| A vulnerability has been identified in Altair Grid Engine (All versions < V2026.0.0). Affected products do not properly handle error messages and discloses sensitive password hash information when processing user authentication requests. This could allow a local attacker to extract password hashes for privileged accounts, which can then be subjected to offline brute-force attacks. | ||||
| CVE-2025-40763 | 1 Siemens | 1 Altair Grid Engine | 2026-04-15 | 7.8 High |
| A vulnerability has been identified in Altair Grid Engine (All versions < V2026.0.0). Affected products do not properly validate environment variables when loading shared libraries, allowing path hijacking through malicious library substitution. This could allow a local attacker to execute arbitrary code with superuser privileges by manipulating the environment variable and placing a malicious library in the controlled path. | ||||
| CVE-2025-40815 | 1 Siemens | 2 Logo!, Siplus Logo! | 2026-04-15 | 7.2 High |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code. | ||||
| CVE-2025-40816 | 1 Siemens | 2 Logo!, Siplus Logo! | 2026-04-15 | 7.6 High |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable. | ||||
| CVE-2025-40817 | 1 Siemens | 2 Logo!, Siplus Logo! | 2026-04-15 | 6.5 Medium |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to change time of the device, which means the device could behave differently. | ||||
| CVE-2025-40827 | 1 Siemens | 2 Software Center, Solid Edge Se2025 | 2026-04-15 | 7.8 High |
| A vulnerability has been identified in Siemens Software Center (All versions < V3.5), Solid Edge SE2025 (All versions < V225.0 Update 10). The affected application is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code via placing a crafted DLL file on the system. | ||||
| CVE-2025-40923 | 2026-04-15 | 7.3 High | ||
| Plack-Middleware-Session before version 0.35 for Perl generates session ids insecurely. The default session id generator returns a SHA-1 hash seeded with the built-in rand function, the epoch time, and the PID. The PID will come from a small set of numbers, and the epoch time may be guessed, if it is not leaked from the HTTP Date header. The built-in rand function is unsuitable for cryptographic usage. Predicable session ids could allow an attacker to gain access to systems. | ||||
| CVE-2025-41116 | 1 Grafana | 1 Grafana | 2026-04-15 | N/A |
| When using the Grafana Databricks Datasource Plugin, if Oauth passthrough is enabled on the datasource, and multiple users are using the same datasource at the same time on a single Grafana instance, it could result in the wrong user identifier being used, and information for which the viewer is not authorized being returned. This issue affects Grafana Databricks Datasource Plugin: from 1.6.0 before 1.12.0 | ||||
| CVE-2025-41358 | 1 Cronosweb I2a | 1 Cronosweb | 2026-04-15 | N/A |
| Direct Object Reference Vulnerability (IDOR) in i2A's CronosWeb, in versions prior to 25.00.00.12, inclusive. This vulnerability could allow an authenticated attacker to access other users' documents by manipulating the ‘documentCode’ parameter in '/CronosWeb/Modulos/Personas/DocumentosPersonales/AdjuntarDocumentosPersonas'. | ||||
| CVE-2025-42882 | 1 Sap | 6 Application Server, Netweaver, Netweaver Abap and 3 more | 2026-04-15 | 4.3 Medium |
| Due to a missing authorization check in SAP NetWeaver Application Server for ABAP, an authenticated attacker with basic privileges could execute a specific function module in ABAP to retrieve restricted technical information from the system. This disclosure of environment details of the system could further assist this attacker to plan subsequent attacks. As a result, this vulnerability has a low impact on confidentiality, with no impact on the integrity or availability of the application. | ||||