Export limit exceeded: 365581 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Export limit exceeded: 365581 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (365581 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2017-16265 | 1 Insteon | 2 Hub, Hub Firmware | 2025-04-08 | 9.9 Critical |
| Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd l_bt, at 0x9d016104, the value for the `grp` key is copied using `strcpy` to the buffer at `$sp+0x1b4`.This buffer is 8 bytes large, sending anything longer will cause a buffer overflow. | ||||
| CVE-2025-3188 | 1 Phpgurukul | 1 E-diary Management System | 2025-04-08 | 7.3 High |
| A vulnerability classified as critical has been found in PHPGurukul e-Diary Management System 1.0. This affects an unknown part of the file /add-notes.php. The manipulation of the argument Category leads to sql injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. | ||||
| CVE-2025-3206 | 1 Code-projects | 1 Hospital Management System | 2025-04-08 | 6.3 Medium |
| A vulnerability has been found in code-projects Hospital Management System 1.0 and classified as critical. This vulnerability affects unknown code of the file /admin/doctor-specilization.php. The manipulation of the argument doctorspecilization leads to sql injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. | ||||
| CVE-2025-3207 | 1 Code-projects | 1 Patient Record Management System | 2025-04-08 | 6.3 Medium |
| A vulnerability was found in code-projects Patient Record Management System 1.0 and classified as critical. This issue affects some unknown processing of the file /birthing_form.php. The manipulation of the argument birth_id leads to sql injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. | ||||
| CVE-2017-16266 | 1 Insteon | 2 Hub, Hub Firmware | 2025-04-08 | 9.9 Critical |
| Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_b, at 0x9d016530, the value for the `grp` key is copied using `strcpy` to the buffer at `$sp+0x1b4`.This buffer is 8 bytes large, sending anything longer will cause a buffer overflow. | ||||
| CVE-2017-16267 | 1 Insteon | 2 Hub, Hub Firmware | 2025-04-08 | 9.9 Critical |
| Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_b, at 0x9d016578, the value for the `val` key is copied using `strcpy` to the buffer at `$sp+0x2b0`.This buffer is 32 bytes large, sending anything longer will cause a buffer overflow. | ||||
| CVE-2017-16268 | 1 Insteon | 2 Hub, Hub Firmware | 2025-04-08 | 9.9 Critical |
| Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_b, at 0x9d0165c0, the value for the `id` key is copied using `strcpy` to the buffer at `$sp+0x270`.This buffer is 16 bytes large, sending anything longer will cause a buffer overflow. | ||||
| CVE-2017-16269 | 1 Insteon | 2 Hub, Hub Firmware | 2025-04-08 | 9.9 Critical |
| Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_b, at 0x9d01672c, the value for the `s_speaker` key is copied using `strcpy` to the buffer at `$sp+0x2d0`.This buffer is 100 bytes large, sending anything longer will cause a buffer overflow. | ||||
| CVE-2017-16270 | 1 Insteon | 2 Hub, Hub Firmware | 2025-04-08 | 9.9 Critical |
| Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_b, at 0x9d01679c, the value for the `s_sonos_cmd` key is copied using `strcpy` to the buffer at `$sp+0x290`.This buffer is 32 bytes large, sending anything longer will cause a buffer overflow. | ||||
| CVE-2017-16279 | 1 Insteon | 2 Hub, Hub Firmware | 2025-04-08 | 9.9 Critical |
| Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_net, at 0x9d0181a4, the value for the `port` key is copied using `strcpy` to the buffer at `$sp+0x280`.This buffer is 16 bytes large, sending anything longer will cause a buffer overflow. | ||||
| CVE-2017-16280 | 1 Insteon | 2 Hub, Hub Firmware | 2025-04-08 | 9.9 Critical |
| Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_net, at 0x9d0181ec, the value for the `gate` key is copied using `strcpy` to the buffer at `$sp+0x290`.This buffer is 32 bytes large, sending anything longer will cause a buffer overflow. | ||||
| CVE-2017-16281 | 1 Insteon | 2 Hub, Hub Firmware | 2025-04-08 | 9.9 Critical |
| Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_net, at 0x9d018234, the value for the `sub` key is copied using `strcpy` to the buffer at `$sp+0x2b0`.This buffer is 32 bytes large, sending anything longer will cause a buffer overflow. | ||||
| CVE-2017-16282 | 1 Insteon | 2 Hub, Hub Firmware | 2025-04-08 | 9.9 Critical |
| Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_net, at 0x9d01827c, the value for the `dhcp` key is copied using `strcpy` to the buffer at `$sp+0x270`.This buffer is 16 bytes large, sending anything longer will cause a buffer overflow. | ||||
| CVE-2025-3208 | 1 Code-projects | 1 Patient Record Management System | 2025-04-08 | 6.3 Medium |
| A vulnerability was found in code-projects Patient Record Management System 1.0. It has been classified as critical. Affected is an unknown function of the file /xray_print.php. The manipulation of the argument itr_no leads to sql injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. | ||||
| CVE-2017-16283 | 1 Insteon | 2 Hub, Hub Firmware | 2025-04-08 | 9.9 Critical |
| Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_name, at 0x9d0188a8, the value for the `name` key is copied using `strcpy` to the buffer at `$sp+0x2b0`.This buffer is 32 bytes large, sending anything longer will cause a buffer overflow. | ||||
| CVE-2025-3210 | 1 Code-projects | 1 Patient Record Management System | 2025-04-08 | 6.3 Medium |
| A vulnerability was found in code-projects Patient Record Management System 1.0. It has been rated as critical. Affected by this issue is some unknown functionality of the file /birthing_pending.php. The manipulation of the argument birth_id leads to sql injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. | ||||
| CVE-2025-3308 | 1 Adonesevangelista | 1 Online Blood Bank Management System | 2025-04-08 | 7.3 High |
| A vulnerability was found in code-projects Blood Bank Management System 1.0. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file /viewrequest.php. The manipulation of the argument ID leads to sql injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. | ||||
| CVE-2025-32369 | 1 Kentico | 1 Xperience | 2025-04-08 | 6.4 Medium |
| Kentico Xperience before 13.0.181 allows authenticated users to distribute malicious content (for stored XSS) via certain interactions with the media library file upload feature. | ||||
| CVE-2022-4167 | 1 Gitlab | 1 Gitlab | 2025-04-08 | 5.3 Medium |
| Incorrect Authorization check affecting all versions of GitLab EE from 13.11 prior to 15.5.7, 15.6 prior to 15.6.4, and 15.7 prior to 15.7.2 allows group access tokens to continue working even after the group owner loses the ability to revoke them. | ||||
| CVE-2022-4131 | 1 Gitlab | 1 Gitlab | 2025-04-08 | 4.3 Medium |
| An issue has been discovered in GitLab CE/EE affecting all versions starting from 10.8 before 15.5.7, all versions starting from 15.6 before 15.6.4, all versions starting from 15.7 before 15.7.2. An attacker may cause Denial of Service on a GitLab instance by exploiting a regex issue in how the application parses user agents. | ||||