Export limit exceeded: 366060 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (366060 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2023-0348 | 1 Akuvox | 2 E11, E11 Firmware | 2025-01-16 | 7.5 High |
| Akuvox E11 allows direct SIP calls. No access control is enforced by the SIP servers, which could allow an attacker to contact any device within Akuvox to call any other device. | ||||
| CVE-2023-0347 | 1 Akuvox | 2 E11, E11 Firmware | 2025-01-16 | 7.5 High |
| The Akuvox E11 Media Access Control (MAC) address, a primary identifier, combined with the Akuvox E11 IP address, could allow an attacker to identify the device on the Akuvox cloud. | ||||
| CVE-2023-0355 | 1 Akuvox | 2 E11, E11 Firmware | 2025-01-16 | 6.5 Medium |
| Akuvox E11 uses a hard-coded cryptographic key, which could allow an attacker to decrypt sensitive information. | ||||
| CVE-2023-0354 | 1 Akuvox | 2 E11, E11 Firmware | 2025-01-16 | 9.1 Critical |
| The Akuvox E11 web server can be accessed without any user authentication, and this could allow an attacker to access sensitive information, as well as create and download packet captures with known default URLs. | ||||
| CVE-2023-0353 | 1 Akuvox | 2 E11, E11 Firmware | 2025-01-16 | 7.2 High |
| Akuvox E11 uses a weak encryption algorithm for stored passwords and uses a hard-coded password for decryption which could allow the encrypted passwords to be decrypted from the configuration file. | ||||
| CVE-2023-0346 | 1 Akuvox | 2 E11, E11 Firmware | 2025-01-16 | 7.5 High |
| Akuvox E11 cloud login is performed through an unencrypted HTTP connection. An attacker could gain access to the Akuvox cloud and device if the MAC address of a device if known. | ||||
| CVE-2023-0345 | 1 Akuvox | 2 E11, E11 Firmware | 2025-01-16 | 9.8 Critical |
| The Akuvox E11 secure shell (SSH) server is enabled by default and can be accessed by the root user. This password cannot be changed by the user. | ||||
| CVE-2023-0811 | 1 Omron | 256 Sysmac Cj2h-cpu64, Sysmac Cj2h-cpu64-eip, Sysmac Cj2h-cpu64-eip Firmware and 253 more | 2025-01-16 | 9.1 Critical |
| Omron CJ1M unit v4.0 and prior has improper access controls on the memory region where the UM password is stored. If an adversary issues a PROGRAM AREA WRITE command to a specific memory region, they could overwrite the password. This may lead to disabling UM protections or setting a non-ASCII password (non-keyboard characters) and preventing an engineer from viewing or modifying the user program. | ||||
| CVE-2023-1256 | 1 Aveva | 2 Aveva Plant Scada, Telemetry Server | 2025-01-16 | 9.8 Critical |
| The listed versions of AVEVA Plant SCADA and AVEVA Telemetry Server are vulnerable to an improper authorization exploit which could allow an unauthenticated user to remotely read data, cause denial of service, and tamper with alarm states. | ||||
| CVE-2023-0598 | 1 Ge | 1 Ifix | 2025-01-16 | 7.8 High |
| GE Digital Proficy iFIX 2022, GE Digital Proficy iFIX v6.1, and GE Digital Proficy iFIX v6.5 are vulnerable to code injection, which may allow an attacker to insert malicious configuration files in the expected web server execution path and gain full control of the HMI software. | ||||
| CVE-2023-1139 | 1 Deltaww | 1 Infrasuite Device Master | 2025-01-16 | 8.8 High |
| Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targeting the Device-gateway service, which could allow deserialization of requests prior to authentication, resulting in remote code execution. | ||||
| CVE-2023-1138 | 1 Deltaww | 1 Infrasuite Device Master | 2025-01-16 | 7.5 High |
| Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain an improper access control vulnerability, which could allow an attacker to retrieve Gateway configuration files to obtain plaintext credentials. | ||||
| CVE-2023-1144 | 1 Deltaww | 1 Infrasuite Device Master | 2025-01-16 | 8.8 High |
| Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contains an improper access control vulnerability in which an attacker can use the Device-Gateway service and bypass authorization, which could result in privilege escalation. | ||||
| CVE-2023-1137 | 1 Deltaww | 1 Infrasuite Device Master | 2025-01-16 | 6.5 Medium |
| Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which a low-level user could extract files and plaintext credentials of administrator users, resulting in privilege escalation. | ||||
| CVE-2023-1143 | 1 Deltaww | 1 Infrasuite Device Master | 2025-01-16 | 8.8 High |
| In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use Lua scripts, which could allow an attacker to remotely execute arbitrary code. | ||||
| CVE-2023-1134 | 1 Deltaww | 1 Infrasuite Device Master | 2025-01-16 | 7.1 High |
| Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a path traversal vulnerability, which could allow an attacker to read local files, disclose plaintext credentials, and escalate privileges. | ||||
| CVE-2023-1142 | 1 Deltaww | 1 Infrasuite Device Master | 2025-01-16 | 7.5 High |
| In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use URL decoding to retrieve system files, credentials, and bypass authentication resulting in privilege escalation. | ||||
| CVE-2023-1136 | 1 Deltaww | 1 Infrasuite Device Master | 2025-01-16 | 9.8 Critical |
| In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an unauthenticated attacker could generate a valid token, which would lead to authentication bypass. | ||||
| CVE-2023-1141 | 1 Deltaww | 1 Infrasuite Device Master | 2025-01-16 | 8.8 High |
| Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a command injection vulnerability that could allow an attacker to inject arbitrary commands, which could result in remote code execution. | ||||
| CVE-2023-1140 | 1 Deltaww | 1 Infrasuite Device Master | 2025-01-16 | 9.8 Critical |
| Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability that could allow an attacker to achieve unauthenticated remote code execution in the context of an administrator. | ||||