Export limit exceeded: 366014 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (366014 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2023-4215 | 1 Advantech | 1 Webaccess | 2025-01-16 | 6.5 Medium |
| Advantech WebAccess version 9.1.3 contains an exposure of sensitive information to an unauthorized actor vulnerability that could leak user credentials. | ||||
| CVE-2023-34437 | 1 Bakerhughes | 2 Bentley Nevada 3500 System, Bentley Nevada 3500 System Firmware | 2025-01-16 | 7.5 High |
| Baker Hughes – Bently Nevada 3500 System TDI Firmware version 5.05 contains a vulnerability in their password retrieval functionality which could allow an attacker to access passwords stored on the device. | ||||
| CVE-2023-36857 | 1 Bakerhughes | 2 Bentley Nevada 3500 System, Bentley Nevada 3500 System Firmware | 2025-01-16 | 5.4 Medium |
| Baker Hughes – Bently Nevada 3500 System TDI Firmware version 5.05 contains a replay vulnerability which could allow an attacker to replay older captured packets of traffic to the device to gain access. | ||||
| CVE-2023-5059 | 1 Santesoft | 1 Fft Imaging | 2025-01-16 | 7.8 High |
| Santesoft Sante FFT Imaging lacks proper validation of user-supplied data when parsing DICOM files. This could lead to an out-of-bounds read. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process. | ||||
| CVE-2023-39431 | 1 Santesoft | 1 Dicom Viewer Pro | 2025-01-16 | 7.8 High |
| Sante DICOM Viewer Pro lacks proper validation of user-supplied data when parsing DICOM files. This could lead to an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process. | ||||
| CVE-2023-35986 | 1 Santesoft | 1 Dicom Viewer Pro | 2025-01-16 | 7.8 High |
| Sante DICOM Viewer Pro lacks proper validation of user-supplied data when parsing DICOM files. This could lead to a stack-based buffer overflow. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process. | ||||
| CVE-2023-38584 | 1 Weintek | 14 Cmt-fhd, Cmt-fhd Firmware, Cmt-hdm and 11 more | 2025-01-16 | 9.8 Critical |
| In Weintek's cMT3000 HMI Web CGI device, the cgi-bin command_wb.cgi contains a stack-based buffer overflow, which could allow an anonymous attacker to hijack control flow and bypass login authentication. | ||||
| CVE-2023-40145 | 1 Weintek | 14 Cmt-fhd, Cmt-fhd Firmware, Cmt-hdm and 11 more | 2025-01-16 | 8.8 High |
| In Weintek's cMT3000 HMI Web CGI device, an anonymous attacker can execute arbitrary commands after login to the device. | ||||
| CVE-2023-43492 | 1 Weintek | 14 Cmt-fhd, Cmt-fhd Firmware, Cmt-hdm and 11 more | 2025-01-16 | 9.8 Critical |
| In Weintek's cMT3000 HMI Web CGI device, the cgi-bin codesys.cgi contains a stack-based buffer overflow, which could allow an anonymous attacker to hijack control flow and bypass login authentication. | ||||
| CVE-2023-42769 | 1 Sielco | 30 Analog Fm Transmitter Exc1000gt, Analog Fm Transmitter Exc1000gt Firmware, Analog Fm Transmitter Exc1000gx and 27 more | 2025-01-16 | 9.8 Critical |
| The cookie session ID is of insufficient length and can be exploited by brute force, which may allow a remote attacker to obtain a valid session, bypass authentication, and manipulate the transmitter. | ||||
| CVE-2023-45317 | 1 Sielco | 30 Analog Fm Transmitter Exc1000gt, Analog Fm Transmitter Exc1000gt Firmware, Analog Fm Transmitter Exc1000gx and 27 more | 2025-01-16 | 8.8 High |
| The application interface allows users to perform certain actions via HTTP requests without performing any validity checks to verify the requests. This can be exploited to perform certain actions with administrative privileges if a logged-in user visits a malicious web site. | ||||
| CVE-2023-45228 | 1 Sielco | 30 Analog Fm Transmitter Exc1000gt, Analog Fm Transmitter Exc1000gt Firmware, Analog Fm Transmitter Exc1000gx and 27 more | 2025-01-16 | 6.5 Medium |
| The application suffers from improper access control when editing users. A user with read permissions can manipulate users, passwords, and permissions by sending a single HTTP POST request with modified parameters. | ||||
| CVE-2023-41966 | 1 Sielco | 30 Analog Fm Transmitter Exc1000gt, Analog Fm Transmitter Exc1000gt Firmware, Analog Fm Transmitter Exc1000gx and 27 more | 2025-01-16 | 6.5 Medium |
| The application suffers from a privilege escalation vulnerability. A user with read permissions can elevate privileges by sending a HTTP POST to set a parameter. | ||||
| CVE-2023-0897 | 1 Sielco | 6 Polyeco1000, Polyeco1000 Firmware, Polyeco300 and 3 more | 2025-01-16 | 8.8 High |
| Sielco PolyEco1000 is vulnerable to a session hijack vulnerability due to the cookie being vulnerable to a brute force attack, lack of SSL, and the session being visible in requests. | ||||
| CVE-2023-5754 | 1 Sielco | 6 Polyeco1000, Polyeco1000 Firmware, Polyeco300 and 3 more | 2025-01-16 | 9.1 Critical |
| Sielco PolyEco1000 uses a weak set of default administrative credentials that can be easily guessed in remote password attacks and gain full control of the system. | ||||
| CVE-2023-46661 | 1 Sielco | 6 Polyeco1000, Polyeco1000 Firmware, Polyeco300 and 3 more | 2025-01-16 | 9.8 Critical |
| Sielco PolyEco1000 is vulnerable to an attacker escalating their privileges by modifying passwords in POST requests. | ||||
| CVE-2023-46662 | 1 Sielco | 6 Polyeco1000, Polyeco1000 Firmware, Polyeco300 and 3 more | 2025-01-16 | 7.5 High |
| Sielco PolyEco1000 is vulnerable to an information disclosure vulnerability due to improper access control enforcement. An unauthenticated remote attacker can exploit this via a specially crafted request to gain access to sensitive information. | ||||
| CVE-2023-46663 | 1 Sielco | 6 Polyeco1000, Polyeco1000 Firmware, Polyeco300 and 3 more | 2025-01-16 | 7.5 High |
| Sielco PolyEco1000 is vulnerable to an attacker bypassing authorization and accessing resources behind protected pages. The application interface allows users to perform certain actions via HTTP requests without performing any validity checks to verify the requests. | ||||
| CVE-2023-46664 | 1 Sielco | 6 Polyeco1000, Polyeco1000 Firmware, Polyeco300 and 3 more | 2025-01-16 | 7.5 High |
| Sielco PolyEco1000 is vulnerable to an improper access control vulnerability when the application provides direct access to objects based on user-supplied input. As a result of this vulnerability attackers can bypass authorization and access resources behind protected pages. | ||||
| CVE-2023-46665 | 1 Sielco | 6 Polyeco1000, Polyeco1000 Firmware, Polyeco300 and 3 more | 2025-01-16 | 9.8 Critical |
| Sielco PolyEco1000 is vulnerable to an authentication bypass vulnerability due to an attacker modifying passwords in a POST request and gain unauthorized access to the affected device with administrative privileges. | ||||