Export limit exceeded: 372376 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (372376 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2022-28085 | 1 Htmldoc Project | 1 Htmldoc | 2025-02-05 | 7.8 High |
| A flaw was found in htmldoc commit 31f7804. A heap buffer overflow in the function pdf_write_names in ps-pdf.cxx may lead to arbitrary code execution and Denial of Service (DoS). | ||||
| CVE-2022-32513 | 1 Schneider-electric | 12 5500ac2, 5500ac2 Firmware, 5500nac and 9 more | 2025-02-05 | 9.8 Critical |
| A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0) | ||||
| CVE-2022-32514 | 1 Schneider-electric | 12 5500ac2, 5500ac2 Firmware, 5500nac and 9 more | 2025-02-05 | 9.8 Critical |
| A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0) | ||||
| CVE-2022-32522 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
| A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted mathematically reduced data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
| CVE-2022-32523 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
| A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted online data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
| CVE-2022-32524 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
| A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted time reduced data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
| CVE-2022-32525 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
| A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
| CVE-2022-32526 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
| A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted setting value messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
| CVE-2022-32527 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
| A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm cache data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
| CVE-2022-32529 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
| A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted log data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
| CVE-2022-24324 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
| A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073) | ||||
| CVE-2022-2329 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
| A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073) | ||||
| CVE-2022-42970 | 2 Microsoft, Schneider-electric | 8 Windows 10, Windows 11, Windows 7 and 5 more | 2025-02-05 | 9.8 Critical |
| A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261) | ||||
| CVE-2022-42971 | 2 Microsoft, Schneider-electric | 8 Windows 10, Windows 11, Windows 7 and 5 more | 2025-02-05 | 9.8 Critical |
| A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could cause remote code execution when the attacker uploads a malicious JSP file. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261) | ||||
| CVE-2023-29916 | 1 H3c | 1 Magic R200 Firmware | 2025-02-05 | 4.9 Medium |
| H3C Magic R200 version R200V100R004 was discovered to contain a stack overflow via the UpdateWanParams interface at /goform/aspForm. | ||||
| CVE-2023-29915 | 1 H3c | 1 Magic R200 Firmware | 2025-02-05 | 4.9 Medium |
| H3C Magic R200 version R200V100R004 was discovered to contain a stack overflow via CMD parameter at /goform/aspForm. | ||||
| CVE-2023-26100 | 1 Progress | 1 Flowmon Os | 2025-02-05 | 6.1 Medium |
| In Progress Flowmon before 12.2.0, an application endpoint failed to sanitize user-supplied input. A threat actor could leverage a reflected XSS vulnerability to execute arbitrary code within the context of a Flowmon user's web browser. | ||||
| CVE-2023-21086 | 1 Google | 1 Android | 2025-02-05 | 7.8 High |
| In isToggleable of SecureNfcEnabler.java and SecureNfcPreferenceController.java, there is a possible way to enable NFC from a secondary account due to a permissions bypass. This could lead to local escalation of privilege from the Guest account with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-11 Android-12 Android-12L Android-13Android ID: A-238298970 | ||||
| CVE-2023-21085 | 1 Google | 1 Android | 2025-02-05 | 8.8 High |
| In nci_snd_set_routing_cmd of nci_hmsgs.cc, there is a possible out of bounds write due to a missing bounds check. This could lead to remote (proximal/adjacent) code execution with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-11 Android-12 Android-12L Android-13Android ID: A-264879662 | ||||
| CVE-2023-21084 | 1 Google | 1 Android | 2025-02-05 | 6.7 Medium |
| In buildPropFile of filesystem.go, there is a possible insecure hash due to an improperly used crypto. This could lead to local escalation of privilege with System execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-13Android ID: A-262892300 | ||||