Export limit exceeded: 37252 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (37252 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2021-33021 1 Xarrow 1 Xarrow 2025-04-16 6.1 Medium
xArrow SCADA versions 7.2 and prior is vulnerable to cross-site scripting due to parameter ‘edate’ of the resource xhisalarm.htm, which may allow an unauthorized attacker to execute arbitrary code.
CVE-2022-1357 1 Cambiumnetworks 1 Cnmaestro 2025-04-16 9.8 Critical
The affected On-Premise cnMaestro allows an unauthenticated attacker to access the cnMaestro server and execute arbitrary code in the privileges of the web server. This lack of validation could allow an attacker to append arbitrary data to the logger command.
CVE-2022-1359 1 Cambiumnetworks 1 Cnmaestro 2025-04-16 5.7 Medium
The affected On-Premise cnMaestro is vulnerable to an arbitrary file-write through improper limitation of a pathname to a restricted directory inside a specific route. If an attacker supplied path traversal charters (../) as part of a filename, the server will save the file where the attacker chooses. This could allow an attacker to write any data to any file in the server.
CVE-2022-1360 1 Cambiumnetworks 1 Cnmaestro 2025-04-16 8.2 High
The affected On-Premise cnMaestro is vulnerable to execution of code on the cnMaestro hosting server. This could allow a remote attacker to change server configuration settings.
CVE-2022-1362 1 Cambiumnetworks 1 Cnmaestro 2025-04-16 5 Medium
The affected On-Premise cnMaestro is vulnerable inside a specific route where a user can upload a crafted package to the system. An attacker could abuse this user-controlled data to execute arbitrary commands on the server.
CVE-2021-42700 1 Inkscape 1 Inkscape 2025-04-16 3.3 Low
Inkscape 0.91 is vulnerable to an out-of-bounds read, which may allow an attacker to have access to unauthorized information.
CVE-2021-42702 1 Inkscape 1 Inkscape 2025-04-16 3.3 Low
Inkscape version 0.91 can access an uninitialized pointer, which may allow an attacker to have access to unauthorized information.
CVE-2021-42704 1 Inkscape 1 Inkscape 2025-04-16 7.8 High
Inkscape version 0.91 is vulnerable to an out-of-bounds write, which may allow an attacker to arbitrary execute code.
CVE-2020-16209 1 Fieldcommgroup 3 Hart-ip Developer Kit, Hart-ip Developer Kit Firmware, Hipserver 2025-04-16 9.8 Critical
A malicious attacker could exploit the interface of the Fieldcomm Group HART-IP (release 1.0.0.0) by constructing messages with sufficiently large payloads to overflow the internal buffer and crash the device, or obtain control of the device.
CVE-2021-32934 1 Throughtek 1 Kalay P2p Software Development Kit 2025-04-16 9.1 Critical
The affected ThroughTek P2P products (SDKs using versions before 3.1.5, any versions with nossl tag, device firmware not using AuthKey for IOTC conneciton, firmware using AVAPI module without enabling DTLS mechanism, and firmware using P2PTunnel or RDT module) do not sufficiently protect data transferred between the local device and ThroughTek servers. This can allow an attacker to access sensitive information, such as camera feeds.
CVE-2022-34150 1 Micodus 2 Mv720, Mv720 Firmware 2025-04-16 7.1 High
The main MiCODUS MV720 GPS tracker web server has an authenticated insecure direct object reference vulnerability on endpoint and parameter device IDs, which accept arbitrary device IDs without further verification.
CVE-2022-2141 1 Micodus 2 Mv720, Mv720 Firmware 2025-04-16 9.8 Critical
SMS-based GPS commands can be executed by MiCODUS MV720 GPS tracker without authentication.
CVE-2022-33944 1 Micodus 2 Mv720, Mv720 Firmware 2025-04-16 6.5 Medium
The main MiCODUS MV720 GPS tracker web server has an authenticated insecure direct object references vulnerability on endpoint and POST parameter “Device ID,” which accepts arbitrary device IDs.
CVE-2022-2107 1 Micodus 2 Mv720, Mv720 Firmware 2025-04-16 9.8 Critical
The MiCODUS MV720 GPS tracker API server has an authentication mechanism that allows devices to use a hard-coded master password. This may allow an attacker to send SMS commands directly to the GPS tracker as if they were coming from the GPS owner’s mobile number.
CVE-2022-1264 1 Inductiveautomation 1 Ignition 2025-04-16 6.8 Medium
The affected product may allow an attacker with access to the Ignition web configuration to run arbitrary code.
CVE-2022-2179 1 Rockwellautomation 4 Micrologix 1100, Micrologix 1100 Firmware, Micrologix 1400 and 1 more 2025-04-16 6.5 Medium
The X-Frame-Options header in Rockwell Automation MicroLogix 1100/1400 Versions 21.007 and prior is not configured in the HTTP response, which could allow clickjacking attacks.
CVE-2022-1704 1 Inductiveautomation 1 Ignition 2025-04-16 7.6 High
Due to an XML external entity reference, the software parses XML in the backup/restore functionality without XML security flags, which may lead to a XXE attack while restoring the backup.
CVE-2022-2634 1 Digi 2 Connectport X2d, Connectport X2d Firmware 2025-04-16 10 Critical
An attacker may be able to execute malicious actions due to the lack of device access protections and device permissions when using the web application. This could lead to uploading python files which can be later executed.
CVE-2022-2005 1 Automationdirect 24 C-more Ea9-pgmsw, C-more Ea9-pgmsw Firmware, C-more Ea9-rhmi and 21 more 2025-04-16 7.5 High
AutomationDirect C-more EA9 HTTP webserver uses an insecure mechanism to transport credentials from client to web server, which may allow an attacker to obtain the login credentials and login as a valid user. This issue affects: AutomationDirect C-more EA9 EA9-T6CL versions prior to 6.73; EA9-T6CL-R versions prior to 6.73; EA9-T7CL versions prior to 6.73; EA9-T7CL-R versions prior to 6.73; EA9-T8CL versions prior to 6.73; EA9-T10CL versions prior to 6.73; EA9-T10WCL versions prior to 6.73; EA9-T12CL versions prior to 6.73; EA9-T15CL versions prior to 6.73; EA9-RHMI versions prior to 6.73; EA9-PGMSW versions prior to 6.73;
CVE-2022-1404 1 Deltaww 1 Cncsoft 2025-04-16 3.3 Low
Delta Electronics CNCSoft (All versions prior to 1.01.32) does not properly sanitize input while processing a specific project file, allowing a possible out-of-bounds read condition.