Export limit exceeded: 368012 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Export limit exceeded: 368012 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (368012 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-30234 2026-04-15 8.3 High
SmartOS, as used in Triton Data Center and other products, has static host SSH keys in the 60f76fd2-143f-4f57-819b-1ae32684e81b image (a Debian 12 LX zone image from 2024-07-26).
CVE-2025-30235 1 Securenvoy 1 Securaccess 2026-04-15 3.5 Low
Shearwater SecurEnvoy SecurAccess Enrol before 9.4.515 is intended to disable accounts that have had more than 10 failed authentication attempts, but instead allows hundreds of failed authentication attempts, because concurrent attempts are mishandled.
CVE-2025-30236 1 Securenvoy 1 Securaccess 2026-04-15 8.6 High
Shearwater SecurEnvoy SecurAccess Enrol before 9.4.515 allows authentication through only a six-digit TOTP code (skipping a password check) if an HTTP POST request contains a SESSION parameter.
CVE-2025-30259 2026-04-15 3.5 Low
The WhatsApp cloud service before late 2024 did not block certain crafted PDF content that can defeat a sandbox protection mechanism and consequently allow remote access to messaging applications by third parties, as exploited in the wild in 2024 for installation of Android malware associated with BIGPRETZEL.
CVE-2025-31510 1 Lemonldap-ng 1 Lemonldap::ng 2026-04-15 7.2 High
In the portal in LemonLDAP::NG before 2.21.0, cross-site scripting (XSS) allows remote attackers to inject arbitrary web script or HTML (into the login page) via the tab parameter, for Choice authentication.
CVE-2025-32067 2026-04-15 5.4 Medium
Improper Input Validation vulnerability in The Wikimedia Foundation Mediawiki - Growth Experiments Extension allows Cross-Site Scripting (XSS).This issue affects Mediawiki - Growth Experiments Extension: from 1.39 through 1.43.
CVE-2025-32069 2026-04-15 5.4 Medium
Improper Input Validation vulnerability in The Wikimedia Foundation Mediawiki - Wikibase Media Info Extension allows Cross-Site Scripting (XSS).This issue affects Mediawiki - Wikibase Media Info Extension: from 1.39 through 1.43.
CVE-2025-32070 2026-04-15 5.4 Medium
Improper Input Validation vulnerability in The Wikimedia Foundation Mediawiki - AJAX Poll Extension allows Cross-Site Scripting (XSS).This issue affects Mediawiki - AJAX Poll Extension: from 1.39 through 1.43.
CVE-2025-32071 2026-04-15 5.4 Medium
Improper Input Validation vulnerability in The Wikimedia Foundation Mediawiki - Wikidata Extension allows Cross-Site Scripting (XSS) from widthheight message via ImageHandler::getDimensionsString()This issue affects Mediawiki - Wikidata Extension: from 1.39 through 1.43.
CVE-2025-32073 2026-04-15 5.4 Medium
Improper Input Validation vulnerability in The Wikimedia Foundation Mediawiki - HTML Tags allows Cross-Site Scripting (XSS).This issue affects Mediawiki - HTML Tags: from 1.39 through 1.43.
CVE-2025-32074 2026-04-15 5.4 Medium
Improper Encoding or Escaping of Output vulnerability in The Wikimedia Foundation Mediawiki - Confirm Account Extension allows Cross-Site Scripting (XSS).This issue affects Mediawiki - Confirm Account Extension: from 1.39 through 1.43.
CVE-2025-29930 2026-04-15 N/A
imFAQ is an advanced questions and answers management system for ImpressCMS. Prior to 1.0.1, if the $_GET['seoOp'] parameter is manipulated to include malicious input (e.g., seoOp=php://filter/read=convert.base64-encode/resource=/var/www/html/config.php), the application could allow an attacker to read sensitive files on the server (Local File Inclusion, LFI). The $_GET['seoOp'] and $_GET['seoArg'] parameters are directly used without sanitization or validation. This is partly mitigated by the fact that the ImpressCMS sensitive files are stored outside the web root, in a folder with a randomized name. The issue has been resolved in imFaq 1.0.1.
CVE-2025-30106 2026-04-15 8.8 High
On IROAD v9 devices, the dashcam has hardcoded default credentials ("qwertyuiop") that cannot be changed by the user. This allows an attacker within Wi-Fi range to connect to the device's network to perform sniffing.
CVE-2025-30109 2026-04-15 6.5 Medium
In the IROAD APK 5.2.5, there are Hardcoded Credentials in the APK for ports 9091 and 9092. The mobile application for the dashcam contains hardcoded credentials that allow an attacker on the local Wi-Fi network to access API endpoints and retrieve sensitive device information, including live and recorded footage.
CVE-2025-30111 2026-04-15 7.5 High
On IROAD v9 devices, one can Remotely Dump Video Footage and the Live Video Stream. The dashcam exposes endpoints that allow unauthorized users, who gained access through other means, to list and download recorded videos, as well as access live video streams without proper authentication.
CVE-2025-30122 2026-04-15 9.8 Critical
An issue was discovered on ROADCAM X3 devices. It has a uniform default credential set that cannot be modified by users, making it easy for attackers to gain unauthorized access to multiple devices.
CVE-2025-30137 2026-04-15 9.8 Critical
An issue was discovered in the G-Net GNET APK 2.6.2. Hardcoded credentials exist in in APK for ports 9091 and 9092. The GNET mobile application contains hardcoded credentials that provide unauthorized access to the dashcam's API endpoints on ports 9091 and 9092. Once the GNET SSID is connected to, the attacker sends a crafted authentication command with TibetList and 000000 to list settings of the dashcam at port 9091. There's a separate set of credentials for port 9092 (stream) that is also exposed in cleartext: admin + tibet. For settings, the required credentials are adim + 000000.
CVE-2025-31929 2026-04-15 4.2 Medium
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions), UL Resi High End 40A w/15118 Hw (8EM1312-4CF18-0FA3) (All versions), UL Resi High End 48A w/15118 Hw (8EM1312-5CF18-0FA3) (All versions), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions). Affected devices do not contain an Immutable Root of Trust in M0 Hardware. An attacker with physical access to the device could use this to execute arbitrary code.
CVE-2025-31930 2026-04-15 8.8 High
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.
CVE-2025-32469 1 Siemens 11 Ruggedcom Rox Mx5000, Ruggedcom Rox Mx5000re, Ruggedcom Rox Rx1400 and 8 more 2026-04-15 9.9 Critical
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX RX1400 (All versions < V2.16.5), RUGGEDCOM ROX RX1500 (All versions < V2.16.5), RUGGEDCOM ROX RX1501 (All versions < V2.16.5), RUGGEDCOM ROX RX1510 (All versions < V2.16.5), RUGGEDCOM ROX RX1511 (All versions < V2.16.5), RUGGEDCOM ROX RX1512 (All versions < V2.16.5), RUGGEDCOM ROX RX1524 (All versions < V2.16.5), RUGGEDCOM ROX RX1536 (All versions < V2.16.5), RUGGEDCOM ROX RX5000 (All versions < V2.16.5). The 'ping' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.