Export limit exceeded: 365581 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (365581 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-40752 | 1 Siemens | 2 Q100, Q200 | 2026-04-15 | 6.2 Medium |
| A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices store the password for the SMTP account as plain text. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes. | ||||
| CVE-2025-40753 | 1 Siemens | 2 Q100, Q200 | 2026-04-15 | 6.2 Medium |
| A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices export the password for the SMTP account as plain text in the Configuration File. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes. | ||||
| CVE-2025-40757 | 1 Siemens | 2 Apogee Pxc, Talon Tc | 2026-04-15 | 5.3 Medium |
| A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC Series (BACnet) (All versions). Affected devices connected to the network allow unrestricted access to sensitive files, such as databases. This could allow an attacker to download encrypted .db file containing passwords. | ||||
| CVE-2025-40758 | 1 Mendix | 2 Mendix, Saml | 2026-04-15 | 8.7 High |
| A vulnerability has been identified in Mendix SAML (Mendix 10.12 compatible) (All versions < V4.0.3), Mendix SAML (Mendix 10.21 compatible) (All versions < V4.1.2), Mendix SAML (Mendix 9.24 compatible) (All versions < V3.6.21). Affected versions of the module insufficiently enforce signature validation and binding checks. This could allow unauthenticated remote attackers to hijack an account in specific SSO configurations. | ||||
| CVE-2025-40759 | 2026-04-15 | 7.8 High | ||
| A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2). Affected products do not properly sanitize stored security properties when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. | ||||
| CVE-2025-40761 | 1 Siemens | 11 Ruggedcom Rox Mx5000, Ruggedcom Rox Mx5000re, Ruggedcom Rox Rx1400 and 8 more | 2026-04-15 | 7.6 High |
| A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions), RUGGEDCOM ROX MX5000RE (All versions), RUGGEDCOM ROX RX1400 (All versions), RUGGEDCOM ROX RX1500 (All versions), RUGGEDCOM ROX RX1501 (All versions), RUGGEDCOM ROX RX1510 (All versions), RUGGEDCOM ROX RX1511 (All versions), RUGGEDCOM ROX RX1512 (All versions), RUGGEDCOM ROX RX1524 (All versions), RUGGEDCOM ROX RX1536 (All versions), RUGGEDCOM ROX RX5000 (All versions). Affected devices do not properly limit access through its Built-In-Self-Test (BIST) mode. This could allow an attacker with physical access to the serial interface to bypass authentication and get access to a root shell on the device. | ||||
| CVE-2025-4076 | 2026-04-15 | 6.3 Medium | ||
| A vulnerability classified as critical has been found in LB-LINK BL-AC3600 up to 1.0.22. This affects the function easy_uci_set_option_string_0 of the file /cgi-bin/lighttpd.cgi of the component Password Handler. The manipulation of the argument routepwd leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2025-40769 | 1 Siemens | 1 Sinec Traffic Analyzer | 2026-04-15 | 7.4 High |
| A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V3.0). The affected application uses a Content Security Policy that allows unsafe script execution methods. This could allow an attacker to execute unauthorized scripts, potentially leading to cross-site scripting attacks. | ||||
| CVE-2025-40771 | 1 Siemens | 6 Simatic Cp 1542sp-1, Simatic Cp 1542sp-1 Irc, Simatic Cp 1543sp-1 and 3 more | 2026-04-15 | 9.8 Critical |
| A vulnerability has been identified in SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.4.24). Affected devices do not properly authenticate configuration connections. This could allow an unauthenticated remote attacker to access the configuration data. | ||||
| CVE-2025-40778 | 1 Isc | 1 Bind 9 | 2026-04-15 | 8.6 High |
| Under certain circumstances, BIND is too lenient when accepting records from answers, allowing an attacker to inject forged data into the cache. This issue affects BIND 9 versions 9.11.0 through 9.16.50, 9.18.0 through 9.18.39, 9.20.0 through 9.20.13, 9.21.0 through 9.21.12, 9.11.3-S1 through 9.16.50-S1, 9.18.11-S1 through 9.18.39-S1, and 9.20.9-S1 through 9.20.13-S1. | ||||
| CVE-2025-40779 | 1 Isc | 1 Kea | 2026-04-15 | 7.5 High |
| If a DHCPv4 client sends a request with some specific options, and Kea fails to find an appropriate subnet for the client, the `kea-dhcp4` process will abort with an assertion failure. This happens only if the client request is unicast directly to Kea; broadcast messages do not cause the problem. This issue affects Kea versions 2.7.1 through 2.7.9, 3.0.0, and 3.1.0. | ||||
| CVE-2025-4078 | 2026-04-15 | 4.3 Medium | ||
| A vulnerability, which was classified as problematic, has been found in Wangshen SecGate 3600 2400. This issue affects some unknown processing of the file ?g=log_export_file. The manipulation of the argument file_name leads to path traversal. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. | ||||
| CVE-2025-40780 | 1 Isc | 1 Bind 9 | 2026-04-15 | 8.6 High |
| In specific circumstances, due to a weakness in the Pseudo Random Number Generator (PRNG) that is used, it is possible for an attacker to predict the source port and query ID that BIND will use. This issue affects BIND 9 versions 9.16.0 through 9.16.50, 9.18.0 through 9.18.39, 9.20.0 through 9.20.13, 9.21.0 through 9.21.12, 9.16.8-S1 through 9.16.50-S1, 9.18.11-S1 through 9.18.39-S1, and 9.20.9-S1 through 9.20.13-S1. | ||||
| CVE-2025-40804 | 1 Siemens | 1 Simatic | 2026-04-15 | 9.1 Critical |
| A vulnerability has been identified in SIMATIC Virtualization as a Service (SIVaaS) (All versions). The affected application exposes a network share without any authentication. This could allow an attacker to access or alter sensitive data without proper authorization. | ||||
| CVE-2025-40816 | 1 Siemens | 2 Logo!, Siplus Logo! | 2026-04-15 | 7.6 High |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable. | ||||
| CVE-2025-40817 | 1 Siemens | 2 Logo!, Siplus Logo! | 2026-04-15 | 6.5 Medium |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to change time of the device, which means the device could behave differently. | ||||
| CVE-2025-40827 | 1 Siemens | 2 Software Center, Solid Edge Se2025 | 2026-04-15 | 7.8 High |
| A vulnerability has been identified in Siemens Software Center (All versions < V3.5), Solid Edge SE2025 (All versions < V225.0 Update 10). The affected application is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code via placing a crafted DLL file on the system. | ||||
| CVE-2025-40846 | 2026-04-15 | N/A | ||
| Improper Input Validation, the returnUrl parameter in Account Security Settings lacks proper input validation, allowing attackers to redirect users to malicious websites (Open Redirect) and inject JavaScript code to perform cross site scripting attack. The vulnerability affects Halo versions up to 2.174.101 and all versions between 2.175.1 and 2.184.21 | ||||
| CVE-2025-40890 | 1 Nozomi Networks | 2 Cmc, Guardian | 2026-04-15 | 7.9 High |
| A Stored Cross-Site Scripting vulnerability was discovered in the Dashboards functionality due to improper validation of an input parameter. An authenticated low-privilege user can craft a malicious dashboard containing a JavaScript payload and share it with victim users, or a victim can be socially engineered to import a malicious dashboard template. When the victim views or imports the dashboard, the XSS executes in their browser context, allowing the attacker to perform unauthorized actions as the victim, such as modify application data, disrupt application availability, and access limited sensitive information. | ||||
| CVE-2025-3445 | 1 Mholt | 1 Archiver | 2026-04-15 | 8.1 High |
| A Path Traversal "Zip Slip" vulnerability has been identified in mholt/archiver in Go. This vulnerability allows using a crafted ZIP file containing path traversal symlinks to create or overwrite files with the user's privileges or application utilizing the library. When using the archiver.Unarchive functionality with ZIP files, like this: archiver.Unarchive(zipFile, outputDir), A crafted ZIP file can be extracted in such a way that it writes files to the affected system with the same privileges as the application executing this vulnerable functionality. Consequently, sensitive files may be overwritten, potentially leading to privilege escalation, code execution, and other severe outcomes in some cases. It's worth noting that a similar vulnerability was found in TAR files (CVE-2024-0406). Although a fix was implemented, it hasn't been officially released, and the affected project has since been deprecated. The successor to mholt/archiver is a new project called mholt/archives, and its initial release (v0.1.0) removes the Unarchive() functionality. | ||||