Export limit exceeded: 370601 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (370601 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-24008 2026-04-15 6.5 Medium
A vulnerability has been identified in SIRIUS 3RK3 Modular Safety System (MSS) (All versions), SIRIUS Safety Relays 3SK2 (All versions). The affected devices do not encrypt data in transit. An attacker with network access could eavesdrop the connection and retrieve sensitive information, including obfuscated safety passwords.
CVE-2025-24308 2026-04-15 7.5 High
Improper input validation in the UEFI firmware error handler for the Intel(R) Server D50DNP and M50FCP may allow a privileged user to potentially enable escalation of privilege via local access.
CVE-2024-56803 2026-04-15 N/A
Ghostty is a cross-platform terminal emulator. Ghostty, as allowed by default in 1.0.0, allows attackers to modify the window title via a certain character escape sequence and then insert it back to the command line in the user's terminal, e.g. when the user views a file containing the malicious sequence, which could allow the attacker to execute arbitrary commands. This attack requires an attacker to send malicious escape sequences followed by convincing the user to physically press the "enter" key. Fixed in Ghostty v1.0.1.
CVE-2025-24510 2026-04-15 6.5 Medium
A vulnerability has been identified in MS/TP Point Pickup Module (All versions). Affected devices improperly handle specific incoming BACnet MSTP messages. This could allow an attacker residing in the same BACnet network to send a specially crafted MSTP message that results in a denial of service condition of the targeted device. A power cycle is required to restore the device's normal operation.
CVE-2025-24811 2026-04-15 7.5 High
A vulnerability has been identified in SIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0), SIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0), SIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1HE40-0XB0), SIMATIC S7-1200 CPU 1212C AC/DC/Rly (6ES7212-1BE40-0XB0), SIMATIC S7-1200 CPU 1212C DC/DC/DC (6ES7212-1AE40-0XB0), SIMATIC S7-1200 CPU 1212C DC/DC/Rly (6ES7212-1HE40-0XB0), SIMATIC S7-1200 CPU 1212FC DC/DC/DC (6ES7212-1AF40-0XB0), SIMATIC S7-1200 CPU 1212FC DC/DC/Rly (6ES7212-1HF40-0XB0), SIMATIC S7-1200 CPU 1214C AC/DC/Rly (6ES7214-1BG40-0XB0), SIMATIC S7-1200 CPU 1214C DC/DC/DC (6ES7214-1AG40-0XB0), SIMATIC S7-1200 CPU 1214C DC/DC/Rly (6ES7214-1HG40-0XB0), SIMATIC S7-1200 CPU 1214FC DC/DC/DC (6ES7214-1AF40-0XB0), SIMATIC S7-1200 CPU 1214FC DC/DC/Rly (6ES7214-1HF40-0XB0), SIMATIC S7-1200 CPU 1215C AC/DC/Rly (6ES7215-1BG40-0XB0), SIMATIC S7-1200 CPU 1215C DC/DC/DC (6ES7215-1AG40-0XB0), SIMATIC S7-1200 CPU 1215C DC/DC/Rly (6ES7215-1HG40-0XB0), SIMATIC S7-1200 CPU 1215FC DC/DC/DC (6ES7215-1AF40-0XB0), SIMATIC S7-1200 CPU 1215FC DC/DC/Rly (6ES7215-1HF40-0XB0), SIMATIC S7-1200 CPU 1217C DC/DC/DC (6ES7217-1AG40-0XB0), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-2XB0), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-4XB0), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-2XB0), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-4XB0), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-2XB0), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-4XB0), SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL (6AG2212-1AE40-1XB0), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-2XB0), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-4XB0), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-5XB0), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-2XB0), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-4XB0), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-5XB0), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-2XB0), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-4XB0), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-5XB0), SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL (6AG2214-1AG40-1XB0), SIPLUS S7-1200 CPU 1214FC DC/DC/DC (6AG1214-1AF40-5XB0), SIPLUS S7-1200 CPU 1214FC DC/DC/RLY (6AG1214-1HF40-5XB0), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-2XB0), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-4XB0), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-5XB0), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-2XB0), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-4XB0), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-2XB0), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-4XB0), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-5XB0), SIPLUS S7-1200 CPU 1215C DC/DC/DC (6AG1215-1AG40-5XB0), SIPLUS S7-1200 CPU 1215FC DC/DC/DC (6AG1215-1AF40-5XB0). Affected devices do not process correctly certain special crafted packets sent to port 80/tcp, which could allow an unauthenticated attacker to cause a denial of service in the device.
CVE-2025-24869 2026-04-15 4.3 Medium
SAP NetWeaver Application Server Java allows an attacker to access an endpoint that can disclose information about deployed server components, including their XML definitions. This information should ideally be restricted to customer administrators, even though they may not need it. These XML files are not entirely SAP-internal as they are deployed with the server. In such a scenario, sensitive information could be exposed without compromising its integrity or availability.
CVE-2025-24876 2026-04-15 8.1 High
The SAP Approuter Node.js package version v16.7.1 and before is vulnerable to Authentication bypass. When trading an authorization code an attacker can steal the session of the victim by injecting malicious payload causing High impact on confidentiality and integrity of the application
CVE-2024-53943 2026-04-15 6.1 Medium
An issue was discovered in NRadio N8-180 NROS-1.9.2.n3.c5 devices. The /cgi-bin/luci/nradio/basic/radio endpoint is vulnerable to XSS via the 2.4 GHz and 5 GHz name parameters, allowing an attacker to execute JavaScript within the context of the current user by injecting JavaScript into the SSID field. If an administrator logs into the device, the injected script runs in their browser, executing the malicious payload.
CVE-2024-53522 2026-04-15 7.5 High
Bangkok Medical Software HOSxP XE v4.64.11.3 was discovered to contain a hardcoded IDEA Key-IV pair in the HOSxPXE4.exe and HOS-WIN32.INI components. This allows attackers to access sensitive information.
CVE-2024-52814 1 Argoproj 1 Argo-helm 2026-04-15 2.8 Low
Argo Helm is a collection of community maintained charts for `argoproj.github.io` projects. Prior to version 0.45.0, the `workflow-role`) lacks granularity in its privileges, giving permissions to `workflowtasksets` and `workflowartifactgctasks` to all workflow Pods, when only certain types of Pods created by the Controller require these privileges. The impact is minimal, as an attack could only affect status reporting for certain types of Pods and templates. Version 0.45.0 fixes the issue.
CVE-2019-20472 2026-04-15 6.2 Medium
An issue was discovered on One2Track 2019-12-08 devices. Any SIM card used with the device cannot have a PIN configured. If a PIN is configured, the device simply produces a "Remove PIN and restart!" message, and cannot be used. This makes it easier for an attacker to use the SIM card by stealing the device.
CVE-2019-20469 2026-04-15 4.6 Medium
An issue was discovered on One2Track 2019-12-08 devices. Confidential information is needlessly stored on the smartwatch. Audio files are stored in .amr format, in the audior directory. An attacker who has physical access can retrieve all audio files by connecting via a USB cable.
CVE-2019-20462 2026-04-15 5.3 Medium
An issue was discovered on Alecto IVM-100 2019-11-12 devices. The device comes with a serial interface at the board level. By attaching to this serial interface and rebooting the device, a large amount of information is disclosed. This includes the view password and the password of the Wi-Fi access point that the device used.
CVE-2019-20461 1 Alecto 1 Ivm-100 Firmware 2026-04-15 9.8 Critical
An issue was discovered on Alecto IVM-100 2019-11-12 devices. The device uses a custom UDP protocol to start and control video and audio services. The protocol has been partially reverse engineered. Based upon the reverse engineering, no password or username is ever transferred over this protocol. Thus, one can set up the camera connection feed with only the encoded UID. It is possible to set up sessions with the camera over the Internet by using the encoded UID and the custom UDP protocol, because authentication happens at the client side.
CVE-2019-20460 1 Epson 1 Xp-255 2026-04-15 8.8 High
An issue was discovered on Epson Expression Home XP255 20.08.FM10I8 devices. POST requests don't require (anti-)CSRF tokens or other mechanisms for validating that the request is from a legitimate source. In addition, CSRF attacks can be used to send text directly to the RAW printer interface. For example, an attack could deliver a worrisome printout to an end user.
CVE-2019-20459 1 Epson 1 Xp-255 2026-04-15 8.4 High
An issue was discovered on Epson Expression Home XP255 20.08.FM10I8 devices. With the SNMPv1 public community, all values can be read, and with the epson community, all the changeable values can be written/updated, as demonstrated by permanently disabling the network card or changing the DNS servers.
CVE-2019-20458 1 Epson 1 Xp-255 2026-04-15 8.8 High
An issue was discovered on Epson Expression Home XP255 20.08.FM10I8 devices. By default, the device comes (and functions) without a password. The user is at no point prompted to set up a password on the device (leaving a number of devices without a password). In this case, anyone connecting to the web admin panel is capable of becoming admin without using any credentials.
CVE-2019-20457 1 Brother 1 Mfc-j491dw 2026-04-15 9.1 Critical
An issue was discovered on Brother MFC-J491DW C1806180757 devices. The printer's web-interface password hash can be retrieved without authentication, because the response header of any failed login attempt returns an incomplete authorization cookie. The value of the authorization cookie is the MD5 hash of the password in hexadecimal. An attacker can easily derive the true MD5 hash from this, and use offline cracking attacks to obtain administrative access to the device.
CVE-2024-52034 1 Myscada 2 Mypro Manager, Mypro Runtime 2026-04-15 10 Critical
An OS Command Injection vulnerability exists within myPRO Manager. A parameter within a command can be exploited by an unauthenticated remote attacker to inject arbitrary operating system commands.
CVE-2024-51074 2026-04-15 6.7 Medium
Incorrect access control in KIA Seltos vehicle instrument cluster with software and hardware v1.0 allows attackers to arbitrarily change odometer readings in the vehicle by targeting the instrument cluster through the unsecured CAN network. NOTE: this is disputed by the supplier because the CAN bus is not externally exposed, and because the packets can only increase the odometer reading (which typically has no value to an adversary). Also, this is disputed by the Supplier because the findings came from a potentially unrealistic test environment (an isolated ECU part that was not in a vehicle), and because the observed behavior follows the UDS (Unified Diagnostic Services) specification.