Export limit exceeded: 365060 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Export limit exceeded: 365060 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (365060 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-35106 | 2026-04-15 | 4.6 Medium | ||
| NEXTU FLETA AX1500 WIFI6 v1.0.3 was discovered to contain a buffer overflow at /boafrm/formIpQoS. This vulnerability allows attackers to cause a Denial of Service (DoS) or potentially arbitrary code execution via a crafted POST request. | ||||
| CVE-2024-35168 | 2026-04-15 | 4.3 Medium | ||
| Missing Authorization vulnerability in Discourse WP Discourse.This issue affects WP Discourse: from n/a through 2.5.1. | ||||
| CVE-2024-35214 | 1 Blackberry | 1 Cylanceoptics | 2026-04-15 | N/A |
| A tampering vulnerability in the CylanceOPTICS Windows Installer Package of CylanceOPTICS for Windows version 3.2 and 3.3 could allow an attacker to potentially uninstall CylanceOPTICS from a system thereby leaving it with only the protection of CylancePROTECT. | ||||
| CVE-2024-35241 | 2 Fedoraproject, Getcomposer | 2 Fedora, Composer | 2026-04-15 | 8.8 High |
| Composer is a dependency manager for PHP. On the 2.x branch prior to versions 2.2.24 and 2.7.7, the `status`, `reinstall` and `remove` commands with packages installed from source via git containing specially crafted branch names in the repository can be used to execute code. Patches for this issue are available in version 2.2.24 for 2.2 LTS or 2.7.7 for mainline. As a workaround, avoid installing dependencies via git by using `--prefer-dist` or the `preferred-install: dist` config setting. | ||||
| CVE-2024-35242 | 2 Fedoraproject, Getcomposer | 2 Fedora, Composer | 2026-04-15 | 8.8 High |
| Composer is a dependency manager for PHP. On the 2.x branch prior to versions 2.2.24 and 2.7.7, the `composer install` command running inside a git/hg repository which has specially crafted branch names can lead to command injection. This requires cloning untrusted repositories. Patches are available in version 2.2.24 for 2.2 LTS or 2.7.7 for mainline. As a workaround, avoid cloning potentially compromised repositories. | ||||
| CVE-2024-35244 | 2026-04-15 | 9.1 Critical | ||
| There are several hidden accounts. Some of them are intended for maintenance engineers, and with the knowledge of their passwords (e.g., by examining the coredump), these accounts can be used to re-configure the device. As for the details of affected product names, model numbers, and versions, refer to the information provided by the respective vendors listed under [References]. | ||||
| CVE-2024-35245 | 1 Intel | 1 Proset\/wireless Wifi | 2026-04-15 | 6.7 Medium |
| Uncontrolled search path element in some Intel(R) PROSet/Wireless WiFi software for Windows before version 23.60 may allow an authenticated user to potentially enable escalation of privilege via local access. | ||||
| CVE-2024-35288 | 1 Gonitro | 1 Nitro Pdf Pro | 2026-04-15 | 7.8 High |
| Nitro PDF Pro before 13.70.8.82 and 14.x before 14.26.1.0 allows Local Privilege Escalation in the MSI Installer because custom actions occur unsafely in repair mode. CertUtil is run in a conhost.exe window, and there is a mechanism allowing CTRL+o to launch cmd.exe as NT AUTHORITY\SYSTEM. | ||||
| CVE-2024-35292 | 1 Siemens | 10 Simatic S7-200 Smart Cpu Cr40, Simatic S7-200 Smart Cpu Cr60, Simatic S7-200 Smart Cpu Sr20 and 7 more | 2026-04-15 | 8.2 High |
| A vulnerability has been identified in SIMATIC S7-200 SMART CPU CR40 (6ES7288-1CR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU CR60 (6ES7288-1CR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA1) (All versions). Affected devices are using a predictable IP ID sequence number. This leaves the system susceptible to a family of attacks which rely on the use of predictable IP ID sequence numbers as their base method of attack and eventually could allow an attacker to create a denial of service condition. | ||||
| CVE-2024-35293 | 2026-04-15 | 9.1 Critical | ||
| An unauthenticated remote attacker may use a missing authentication for critical function vulnerability to reboot or erase the affected devices resulting in data loss and/or a DoS. | ||||
| CVE-2024-35294 | 2026-04-15 | 6.5 Medium | ||
| An unauthenticated remote attacker may use the devices traffic capture without authentication to grab plaintext administrative credentials. | ||||
| CVE-2024-35295 | 2026-04-15 | 6.1 Medium | ||
| A vulnerability has been identified in Perfect Harmony GH180 (All versions >= V8.0 < V8.3.3 with NXGPro+ controller manufactured between April 2020 to April 2025). The maintenance connection of affected devices fails to protect access to the device's control unit configuration. This could allow an attacker with physical access to the maintenance connection's door port to perform arbitrary configuration changes. | ||||
| CVE-2024-35298 | 2026-04-15 | 4.3 Medium | ||
| Improper authorization in handler for custom URL scheme issue in 'ZOZOTOWN' App for Android versions prior to 7.39.6 allows an attacker to lead a user to access an arbitrary website via another application installed on the user's device. As a result, the user may become a victim of a phishing attack. | ||||
| CVE-2024-35303 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2026-04-15 | 7.8 High |
| A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0012), Tecnomatix Plant Simulation V2404 (All versions < V2404.0001). The affected applications contain a type confusion vulnerability while parsing specially crafted MODEL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-22958) | ||||
| CVE-2024-35371 | 1 Ant-media | 1 Ant-media-server | 2026-04-15 | 7.5 High |
| Ant-Media-Serverv2.8.2 is affected by Improper Output Neutralization for Logs. The vulnerability stems from insufficient input sanitization in the logging mechanism. Without proper filtering or validation, user-controllable data, such as identifiers or other sensitive information, can be included in log entries without restrictions. | ||||
| CVE-2024-35526 | 2026-04-15 | 5.9 Medium | ||
| An issue in Daemon PTY Limited FarCry Core framework before 7.2.14 allows attackers to access sensitive information in the /facade directory. | ||||
| CVE-2024-35474 | 2026-04-15 | 6.5 Medium | ||
| A Directory Traversal vulnerability in iceice666 ResourcePack Server before v1.0.8 allows a remote attacker to disclose files on the server, via setPath in ResourcePackFileServer.kt. | ||||
| CVE-2024-35495 | 2026-04-15 | 4.3 Medium | ||
| An Information Disclosure vulnerability in the Telemetry component in TP-Link Kasa KP125M V1.0.0 and Tapo P125M 1.0.0 Build 220930 Rel.143947 allows attackers to observe device state via observing network traffic. | ||||
| CVE-2024-35515 | 1 Sqlitedict | 1 Sqlitedict | 2026-04-15 | 9.8 Critical |
| Insecure deserialization in sqlitedict up to v2.1.0 allows attackers to execute arbitrary code. | ||||
| CVE-2024-35532 | 2026-04-15 | 9.1 Critical | ||
| An XML External Entity (XXE) injection vulnerability in Intersec Geosafe-ea 2022.12, 2022.13, and 2022.14 allows attackers to perform arbitrary file reading under the privileges of the running process, make SSRF requests, or cause a Denial of Service (DoS) via unspecified vectors. | ||||