Export limit exceeded: 382413 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (382413 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-12420 | 2026-04-15 | 6.5 Medium | ||
| The The WPMobile.App — Android and iOS Mobile Application plugin for WordPress is vulnerable to arbitrary shortcode execution in all versions up to, and including, 11.52. This is due to the software allowing users to execute an action that does not properly validate a value before running do_shortcode. This makes it possible for unauthenticated attackers to execute arbitrary shortcodes. | ||||
| CVE-2025-27244 | 2026-04-15 | N/A | ||
| AssetView and AssetView CLOUD contain an issue with acquiring sensitive information from sent data to the developer. If exploited, sensitive information may be obtained by a remote unauthenticated attacker. | ||||
| CVE-2025-22373 | 2026-04-15 | N/A | ||
| Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in SicommNet BASEC on SaaS allows Reflected XSS, XSS Through HTTP Query Strings, Rendering of Arbitrary HTML and alternation of CSS Styles This issue affects BASEC: from 14 Dec 2021. | ||||
| CVE-2025-22234 | 1 Spring | 1 Spring | 2026-04-15 | 5.3 Medium |
| The fix applied in CVE-2025-22228 inadvertently broke the timing attack mitigation implemented in DaoAuthenticationProvider. This can allow attackers to infer valid usernames or other authentication behavior via response-time differences under certain configurations. | ||||
| CVE-2025-27212 | 2 Ubiquiti, Ui | 5 Unifi Access Points, Unifi Os, Intercom and 2 more | 2026-04-15 | 9.8 Critical |
| An Improper Input Validation in certain UniFi Access devices could allow a Command Injection by a malicious actor with access to UniFi Access management network. Affected Products: UniFi Access Reader Pro (Version 2.14.21 and earlier) UniFi Access G2 Reader Pro (Version 1.10.32 and earlier) UniFi Access G3 Reader Pro (Version 1.10.30 and earlier) UniFi Access Intercom (Version 1.7.28 and earlier) UniFi Access G3 Intercom (Version 1.7.29 and earlier) UniFi Access Intercom Viewer (Version 1.3.20 and earlier) Mitigation: Update UniFi Access Reader Pro Version 2.15.9 or later Update UniFi Access G2 Reader Pro Version 1.11.23 or later Update UniFi Access G3 Reader Pro Version 1.11.22 or later Update UniFi Access Intercom Version 1.8.22 or later Update UniFi Access G3 Intercom Version 1.8.22 or later Update UniFi Access Intercom Viewer Version 1.4.39 or later | ||||
| CVE-2025-9228 | 1 Mobile-industrial-robots | 5 Mir100, Mir1000, Mir200 and 2 more | 2026-04-15 | 4.3 Medium |
| MiR software versions prior to version 3.0.0 have insufficient authorization controls when creating text notes, allowing low-privilege users to create notes which are intended only for administrative users. | ||||
| CVE-2025-9225 | 1 Mobile-industrial-robots | 5 Mir100, Mir1000, Mir200 and 2 more | 2026-04-15 | 5.5 Medium |
| Stored cross-site scripting (XSS) in the web interface of MiR software versions prior to 3.0.0 on MiR Robots and MiR Fleet allows execution of arbitrary JavaScript code in a victim’s browser | ||||
| CVE-2025-9193 | 2026-04-15 | 3.5 Low | ||
| A flaw has been found in TOTVS Portal Meu RH up to 12.1.17. Impacted is an unknown function of the component Password Reset Handler. Executing manipulation of the argument redirectUrl can lead to open redirect. The attack may be performed from a remote location. The exploit has been published and may be used. Upgrading to version 12.1.2410.274, 12.1.2502.178 and 12.1.2506.121 is recommended to address this issue. It is recommended to upgrade the affected component. The vendor explains, that "[o]ur internal validation (...) confirms that the reported behavior does not exist in currently supported releases. In these tests, the redirectUrl parameter is ignored, and no malicious redirection occurs." This vulnerability only affects products that are no longer supported by the maintainer. | ||||
| CVE-2024-1142 | 2026-04-15 | 5.4 Medium | ||
| Path Traversal in Sonatype IQ Server from version 143 allows remote authenticated attackers to overwrite or delete files via a specially crafted request. Version 171 fixes this issue. | ||||
| CVE-2020-36925 | 2026-04-15 | 9.8 Critical | ||
| Arteco Web Client DVR/NVR contains a session hijacking vulnerability with insufficient session ID complexity that allows remote attackers to bypass authentication. Attackers can brute force session IDs within a specific numeric range to obtain valid sessions and access live camera streams without authorization. | ||||
| CVE-2025-21065 | 2026-04-15 | 6.6 Medium | ||
| Improper input validation in Retail Mode prior to version 5.59.11 allows self attackers to execute privileged commands on their own devices. | ||||
| CVE-2020-36921 | 2026-04-15 | 7.5 High | ||
| RED-V Super Digital Signage System 5.1.1 contains an information disclosure vulnerability that allows unauthenticated attackers to access sensitive webserver log files. Attackers can visit multiple endpoints to retrieve system resources and debug log information without authentication. | ||||
| CVE-2024-52787 | 1 Librechat | 1 Librechat | 2026-04-15 | 9.1 Critical |
| An issue in the upload_documents method of libre-chat v0.0.6 allows attackers to execute a path traversal via supplying a crafted filename in an uploaded file. | ||||
| CVE-2020-36920 | 2026-04-15 | 8.8 High | ||
| iDS6 DSSPro Digital Signage System 6.2 contains an improper access control vulnerability that allows authenticated users to elevate privileges through console JavaScript functions. Attackers can create users, modify roles and permissions, and potentially achieve full application takeover by exploiting insecure direct object references. | ||||
| CVE-2025-8449 | 1 Schneider-electric | 3 Ecostruxure Building Operation Enterprise Server, Ecostruxure Enterprise Server, Ecostruxure Workstation | 2026-04-15 | N/A |
| CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause a denial of service when an authenticated user sends a specially crafted request to a specific endpoint from within the BMS network. | ||||
| CVE-2020-36916 | 2026-04-15 | 8.8 High | ||
| TDM Digital Signage PC Player 4.1.0.4 contains an elevation of privileges vulnerability that allows authenticated users to modify executable files. Attackers can leverage the 'Modify' permissions for authenticated users to replace executable files with malicious binaries and gain elevated system access. | ||||
| CVE-2025-8448 | 1 Schneider-electric | 2 Ecostruxure Building Operation Enterprise Server, Ecostruxure Workstation | 2026-04-15 | N/A |
| CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause unauthorized access to sensitive credential data when an attacker is able to capture local SMB traffic between a valid user within the BMS network and the vulnerable products. | ||||
| CVE-2020-36915 | 2026-04-15 | 7.5 High | ||
| Adtec Digital SignEdje Digital Signage Player v2.08.28 contains multiple hardcoded default credentials that allow unauthenticated remote access to web, telnet, and SSH interfaces. Attackers can exploit these credentials to gain root-level access and execute system commands across multiple Adtec Digital product versions. | ||||
| CVE-2025-8286 | 1 Guralp | 1 Fmus | 2026-04-15 | N/A |
| The affected products expose an unauthenticated Telnet-based command line interface that could allow an attacker to modify hardware configurations, manipulate data, or factory reset the device. | ||||
| CVE-2020-36912 | 2026-04-15 | 9.8 Critical | ||
| Plexus anblick Digital Signage Management 3.1.13 contains an open redirect vulnerability in the 'PantallaLogin' script that allows attackers to manipulate the 'pagina' GET parameter. Attackers can craft malicious links that redirect users to arbitrary websites by exploiting improper input validation in the parameter. | ||||