Export limit exceeded: 29196 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (29196 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-43652 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. | ||||
| CVE-2024-43655 | 2026-04-15 | N/A | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43656 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43657 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43658 | 2026-04-15 | N/A | ||
| Patch traversal, External Control of File Name or Path vulnerability in Iocharger Home allows deletion of arbitrary files This issue affects Iocharger firmware for AC model before firmware version 25010801. Likelihood: High, but requires authentication Impact: Critical – The vulnerability can be used to delete any file on the charging station, severely impacting the integrity of the charging station. Furthermore, the vulnerability could be used to delete binaries required for the functioning of the charging station, severely impacting the availability of the charging station. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads compromised of the integrity and availability of the device (VVC:N/VI:H/VA:H), with no effect on subsequent systems (SC:N/SI:N/SA:N). We do not forsee a safety impact (S:N). This attack can be automated (AU:Y). | ||||
| CVE-2024-43660 | 2026-04-15 | 7.5 High | ||
| The CGI script <redacted>.sh can be used to download any file on the filesystem. This issue affects Iocharger firmware for AC model chargers beforeversion 24120701. Likelihood: High, but credentials required. Impact: Critical – The script can be used to download any file on the filesystem, including sensitive files such as /etc/shadow, the CGI script source code or binaries and configuration files. CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/S:P/AU:Y CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The confidentiality of all files of the devicd can be compromised (VC:H/VI:N/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, this attack in isolation does not have a safety impact. The attack can be automated (AU:Y). | ||||
| CVE-2024-43662 | 2026-04-15 | N/A | ||
| The <redacted>.exe or <redacted>.exe CGI binary can be used to upload arbitrary files to /tmp/upload/ or /tmp/ respectively as any user, although the user interface for uploading files is only shown to the iocadmin user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – An attacker will need to have knowledge of this CGI binary, e.g. by finding it in firmware. Furthermore, the attacker will need a (low privilege) account to gain access to the <redacted>.exe or <redacted>.exe CGI binary and upload the file, or convince a user with such access to upload it. Impact: Low – The attacker can upload arbitrary files to /tmp/upload/ or /tmp/. However, the attacker is unable to access or use these files without other vulnerabilities. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). Artitrary files can be uploaded, be these files will not be in a location where they can influence confidentiality or availability and have a minimal impact on device integrity (VC:N/VI:L/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, we do not expect this vulnerability to have a safety impact. The attack can be automated (AU:Y). | ||||
| CVE-2024-48806 | 2026-04-15 | 6.8 Medium | ||
| Buffer Overflow vulnerability in Neat Board NFC v.1.20240620.0015 allows a physically proximate attackers to escalate privileges via a crafted payload to the password field | ||||
| CVE-2024-45036 | 2026-04-15 | N/A | ||
| Tophat is a mobile applications testing harness. An Improper Access Control vulnerability can expose the `TOPHAT_APP_TOKEN` token stored in `~/.tophatrc` through use of a malicious Tophat URL controlled by the attacker. The vulnerability allows Tophat to send this token to the attacker's server without any checks to ensure that the server is trusted. This token can then be used to access internal build artifacts, for mobile applications, not intended to be public. The issue has been patched as of version 1.10.0. The ability to request artifacts using a Tophat API has been deprecated as this flow was inherently insecure. Systems that have implemented this kind of endpoint should cease use and invalidate the token immediately. There are no workarounds and all users should update as soon as possible. | ||||
| CVE-2024-45067 | 2026-04-15 | 8.2 High | ||
| Incorrect default permissions in some Intel(R) Gaudi(R) software installers before version 1.18 may allow an authenticated user to potentially enable escalation of privilege via local access. | ||||
| CVE-2024-46464 | 2026-04-15 | 7.8 High | ||
| In PRIMX ZED Enterprise up to 2024.3, technical files stored in local folders with common user access can be manipulated to render the host computer unavailable or to execute programs with an elevation of privilege. | ||||
| CVE-2024-46505 | 2026-04-15 | 9.1 Critical | ||
| Infoblox BloxOne v2.4 was discovered to contain a business logic flaw due to thick client vulnerabilities. | ||||
| CVE-2024-48465 | 1 Mrbs | 1 Mrbs | 2026-04-15 | 9.8 Critical |
| The MRBS version 1.5.0 has an SQL injection vulnerability in the edit_entry_handler.php file, specifically in the rooms%5B%5D parameter | ||||
| CVE-2024-49755 | 2026-04-15 | 3.1 Low | ||
| Duende IdentityServer is an OpenID Connect and OAuth 2.x framework for ASP.NET Core. IdentityServer's local API authentication handler performs insufficient validation of the cnf claim in DPoP access tokens. This allows an attacker to use leaked DPoP access tokens at local api endpoints even without possessing the private key for signing proof tokens. Note that this only impacts custom endpoints within an IdentityServer implementation that have explicitly used the LocalApiAuthenticationHandler for authentication. This vulnerability is patched in IdentityServer 7.0.8. Version 6.3 and below are unaffected, as they do not support DPoP in Local APIs. | ||||
| CVE-2024-49771 | 1 Mpxj | 1 Mpxj | 2026-04-15 | 5.3 Medium |
| MPXJ is an open source library to read and write project plans from a variety of file formats and databases. The patch for the historical vulnerability CVE-2020-35460 in MPXJ is incomplete as there is still a possibility that a malicious path could be constructed which would not be picked up by the original fix and allow files to be written to arbitrary locations. The issue is addressed in MPXJ version 13.5.1. | ||||
| CVE-2024-50307 | 2026-04-15 | 5.5 Medium | ||
| Use of potentially dangerous function issue exists in Chatwork Desktop Application (Windows) versions prior to 2.9.2. If a user clicks a specially crafted link in the application, an arbitrary file may be downloaded from an external website and executed. As a result, arbitrary code may be executed on the device that runs Chatwork Desktop Application (Windows). | ||||
| CVE-2024-51482 | 1 Zoneminder | 1 Zoneminder | 2026-04-15 | 10 Critical |
| ZoneMinder is a free, open source closed-circuit television software application. ZoneMinder v1.37.* <= 1.37.64 is vulnerable to boolean-based SQL Injection in function of web/ajax/event.php. This is fixed in 1.37.65. | ||||
| CVE-2024-53705 | 2026-04-15 | 7.5 High | ||
| A Server-Side Request Forgery vulnerability in the SonicOS SSH management interface allows a remote attacker to establish a TCP connection to an IP address on any port when the user is logged in to the firewall. | ||||
| CVE-2024-56113 | 2026-04-15 | 7.5 High | ||
| Smart Toilet Lab - Motius 1.3.11 is running with debug mode turned on (DEBUG = True) and exposing sensitive information defined in Django settings file through verbose error page. | ||||
| CVE-2024-56826 | 1 Redhat | 1 Enterprise Linux | 2026-04-15 | 5.6 Medium |
| A flaw was found in the OpenJPEG project. A heap buffer overflow condition may be triggered when certain options are specified while using the opj_decompress utility. This can lead to an application crash or other undefined behavior. | ||||