Search

Search Results (366574 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-42978 2026-04-15 3.5 Low
The widely used component that establishes outbound TLS connections in SAP NetWeaver Application Server Java does not reliably match the hostname that is used for the connection against the wildcard hostname defined in the received certificate of remote TLS server. This might lead to the outbound connection being established to a possibly malicious remote TLS server and hence disclose information. Integrity and Availability are not impacted.
CVE-2024-28335 2026-04-15 9.1 Critical
Lektor before 3.3.11 does not sanitize DB path traversal. Thus, shell commands might be executed via a file that is added to the templates directory, if the victim's web browser accesses an untrusted website that uses JavaScript to send requests to localhost port 5000, and the web browser is running on the same machine as the "lektor server" command.
CVE-2024-30516 2 Saasproject, Wordpress 2 Booking Package, Wordpress 2026-04-15 7.5 High
Improper Validation of Specified Quantity in Input vulnerability in SaasProject Booking Package allows Accessing Functionality Not Properly Constrained by ACLs.This issue affects Booking Package: from n/a through 1.6.27.
CVE-2023-41656 3 Elementor, Wordpress, Wpdive 3 Elementor, Wordpress, Better Addons For Elementor 2026-04-15 5.4 Medium
Missing Authorization vulnerability in wpdive Better Elementor Addons allows Exploiting Incorrectly Configured Access Control Security Levels.This issue affects Better Elementor Addons: from n/a through 1.3.7.
CVE-2024-37372 2026-04-15 3.6 Low
The Permission Model assumes that any path starting with two backslashes \ has a four-character prefix that can be ignored, which is not always true. This subtle bug leads to vulnerable edge cases.
CVE-2024-38821 1 Spring 1 Webflux 2026-04-15 9.1 Critical
Spring WebFlux applications that have Spring Security authorization rules on static resources can be bypassed under certain circumstances. For this to impact an application, all of the following must be true: * It must be a WebFlux application * It must be using Spring's static resources support * It must have a non-permitAll authorization rule applied to the static resources support
CVE-2024-40762 1 Sonicwall 1 Sonicos 2026-04-15 9.8 Critical
Use of Cryptographically Weak Pseudo-Random Number Generator (PRNG) in the SonicOS SSLVPN authentication token generator that, in certain cases, can be predicted by an attacker potentially resulting in authentication bypass.
CVE-2024-42011 1 Spotify 1 Spotify App 2026-04-15 7.5 High
The Spotify app 8.9.58 for iOS has a buffer overflow in its use of strcat.
CVE-2024-42028 1 Ubiquiti 1 Unifi Network Application 2026-04-15 8.8 High
A Local privilege escalation vulnerability found in a Self-Hosted UniFi Network Server with UniFi Network Application (Version 8.4.62 and earlier) allows a malicious actor with a local operational system user to execute high privilege actions on UniFi Network Server.
CVE-2025-42985 2026-04-15 6.1 Medium
Due to insufficient sanitization in the SAP BusinessObjects Content Administrator Workbench, attackers could craft malicious URLs and execute scripts in a victim�s browser. This could potentially lead to the exposure or modification of web client data, resulting in low impact on confidentiality and integrity, with no impact on application availability.
CVE-2024-43650 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-42818 1 Fastapi-admin 1 Fastapi-admin Pro 2026-04-15 6.1 Medium
A cross-site scripting (XSS) vulnerability in the Config-Create function of fastapi-admin pro v0.1.4 allows attackers to execute arbitrary web scripts or HTML via a crafted payload injected into the Product Name parameter.
CVE-2025-42987 2026-04-15 4.3 Medium
SAP Manage Processing Rules (For Bank Statement) allows an attacker with basic privileges to edit shared rules of any user by tampering the request parameter. Due to missing authorization check, the attacker can edit rules that should be restricted, compromising the integrity of the application.
CVE-2024-43651 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
CVE-2024-43656 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43657 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43660 2026-04-15 7.5 High
The CGI script <redacted>.sh can be used to download any file on the filesystem. This issue affects Iocharger firmware for AC model chargers beforeversion 24120701. Likelihood: High, but credentials required. Impact: Critical – The script can be used to download any file on the filesystem, including sensitive files such as /etc/shadow, the CGI script source code or binaries and configuration files. CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/S:P/AU:Y CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The confidentiality of all files of the devicd can be compromised (VC:H/VI:N/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, this attack in isolation does not have a safety impact. The attack can be automated (AU:Y).
CVE-2025-42991 2026-04-15 4.3 Medium
SAP S/4HANA (Bank Account Application) does not perform necessary authorization checks. This allows an authenticated 'approver' user to delete attachment from bank account application of other user, leading to a low impact on integrity, with no impact on the confidentiality of the data or the availability of the application.
CVE-2025-42992 1 Sap 1 Sapcar 2026-04-15 6.9 Medium
SAPCAR allows an attacker logged in with high privileges to create a malicious SAR archive in SAPCAR. This could enable the attacker to exploit critical files and directory permissions without breaking signature validation, resulting in potential privilege escalation. This has high impact on integrity, but low impact on confidentiality and availability of the system.
CVE-2025-42998 2026-04-15 5.3 Medium
The security settings in the SAP Business One Integration Framework are not adequately checked, allowing attackers to bypass the 403 Forbidden error and access restricted pages. This leads to low impact on confidentiality of the application, there is no impact on integrity and availability.