Export limit exceeded: 422168 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (422168 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-37742 | 1 Ethz | 1 Safe Exam Browser | 2026-04-15 | 8.2 High |
| Insecure Access Control in Safe Exam Browser (SEB) = 3.5.0 on Windows. The vulnerability allows an attacker to share clipboard data between the SEB kiosk mode and the underlying system, compromising exam integrity. By exploiting this flaw, an attacker can bypass exam controls and gain an unfair advantage during exams. | ||||
| CVE-2025-3758 | 2026-04-15 | N/A | ||
| WF2220 exposes endpoint /cgi-bin-igd/netcore_get.cgi that returns configuration of the device to unauthorized users. Returned configuration includes cleartext password. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-35710 | 1 Wordpress | 1 Wordpress | 2026-04-15 | 5.3 Medium |
| Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Podlove Podlove Web Player.This issue affects Podlove Web Player: from n/a through 5.7.3. | ||||
| CVE-2025-6225 | 2026-04-15 | N/A | ||
| Kieback&Peter Neutrino-GLT product is used for building management. It's web component "SM70 PHWEB" is vulnerable to shell command injection via login form. The injected commands would execute with low privileges. The vulnerability has been fixed in version 9.40.02 | ||||
| CVE-2024-56113 | 2026-04-15 | 7.5 High | ||
| Smart Toilet Lab - Motius 1.3.11 is running with debug mode turned on (DEBUG = True) and exposing sensitive information defined in Django settings file through verbose error page. | ||||
| CVE-2025-23403 | 1 Siemens | 2 Simatic Ipc Diagbase, Simatic Ipc Diagmonitor | 2026-04-15 | 7 High |
| A vulnerability has been identified in SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions). The affected device do not properly restrict the user permission for the registry key. This could allow an authenticated attacker to load vulnerable drivers into the system leading to privilege escalation or bypassing endpoint protection and other security measures. | ||||
| CVE-2025-23189 | 2026-04-15 | 4.3 Medium | ||
| Due to missing authorization check in an RFC enabled function module in transaction SDCCN, an authenticated attacker could generate technical meta-data. This leads to a low impact on integrity. There is no impact on confidentiality or availability | ||||
| CVE-2024-48465 | 1 Mrbs | 1 Mrbs | 2026-04-15 | 9.8 Critical |
| The MRBS version 1.5.0 has an SQL injection vulnerability in the edit_entry_handler.php file, specifically in the rooms%5B%5D parameter | ||||
| CVE-2025-5028 | 2026-04-15 | N/A | ||
| Installation file of ESET security products on Windows allow an attacker to misuse to delete an arbitrary file without having the permissions to do so. | ||||
| CVE-2024-45067 | 2026-04-15 | 8.2 High | ||
| Incorrect default permissions in some Intel(R) Gaudi(R) software installers before version 1.18 may allow an authenticated user to potentially enable escalation of privilege via local access. | ||||
| CVE-2024-48806 | 2026-04-15 | 6.8 Medium | ||
| Buffer Overflow vulnerability in Neat Board NFC v.1.20240620.0015 allows a physically proximate attackers to escalate privileges via a crafted payload to the password field | ||||
| CVE-2025-42998 | 2026-04-15 | 5.3 Medium | ||
| The security settings in the SAP Business One Integration Framework are not adequately checked, allowing attackers to bypass the 403 Forbidden error and access restricted pages. This leads to low impact on confidentiality of the application, there is no impact on integrity and availability. | ||||
| CVE-2025-24313 | 2 Intel, Kubernetes | 2 Device Plugins For Kubernetes, Kubernetes | 2026-04-15 | 4.4 Medium |
| Improper access control for some Device Plugins for Kubernetes software maintained by Intel before version 0.32.0 may allow a privileged user to potentially enable denial of service via local access. | ||||
| CVE-2024-43651 | 2026-04-15 | N/A | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y). | ||||
| CVE-2024-43650 | 2026-04-15 | N/A | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y). | ||||
| CVE-2024-42028 | 1 Ubiquiti | 1 Unifi Network Application | 2026-04-15 | 8.8 High |
| A Local privilege escalation vulnerability found in a Self-Hosted UniFi Network Server with UniFi Network Application (Version 8.4.62 and earlier) allows a malicious actor with a local operational system user to execute high privilege actions on UniFi Network Server. | ||||
| CVE-2024-42011 | 1 Spotify | 1 Spotify App | 2026-04-15 | 7.5 High |
| The Spotify app 8.9.58 for iOS has a buffer overflow in its use of strcat. | ||||
| CVE-2025-59343 | 1 Tar-fs Project | 1 Tar-fs | 2026-04-15 | 7.5 High |
| tar-fs provides filesystem bindings for tar-stream. Versions prior to 3.1.1, 2.1.3, and 1.16.5 are vulnerable to symlink validation bypass if the destination directory is predictable with a specific tarball. This issue has been patched in version 3.1.1, 2.1.4, and 1.16.6. A workaround involves using the ignore option on non files/directories. | ||||
| CVE-2024-23843 | 2026-04-15 | 2.2 Low | ||
| Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability in Genians Genian NAC V5.0, Genians Genian NAC LTS V5.0.This issue affects Genian NAC V5.0: from V5.0.0 through V5.0.60; Genian NAC LTS V5.0: from 5.0.0 LTS through 5.0.55 LTS(Revision 125558), from 5.0.0 LTS through 5.0.56 LTS(Revision 125560). | ||||
| CVE-2024-37728 | 1 Officeweb365 | 1 Officeweb365 | 2026-04-15 | 7.5 High |
| Arbitrary File Read vulnerability in Xi'an Daxi Information Technology Co., Ltd OfficeWeb365 v.7.18.23.0 and v8.6.1.0 allows a remote attacker to obtain sensitive information via the "Pic/Indexes" interface | ||||