Export limit exceeded: 410624 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (410624 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-9825 2026-04-15 5.4 Medium
The Chef Habitat builder-api on-prem-builder package  with any version lower than habitat/builder-api/10315/20240913162802 is vulnerable to indirect object reference (IDOR) by un-authorized deletion of personal token.  Habitat builder consumes builder-api habitat package as a dependency and the vulnerability was specifically due to builder-api habitat package. The fix was made available in habitat/builder-api/10315/20240913162802 and all the subsequent versions after that. We would recommend user to always use on-prem stable channel.
CVE-2024-9162 1 Yaniiliev 1 All In One Wp Migration And Backup 2026-04-15 7.2 High
The All-in-One WP Migration and Backup plugin for WordPress is vulnerable to arbitrary PHP Code Injection due to missing file type validation during the export in all versions up to, and including, 7.86. This makes it possible for authenticated attackers, with Administrator-level access and above, to create an export file with the .php extension on the affected site's server, adding an arbitrary PHP code to it, which may make remote code execution possible.
CVE-2024-58101 2026-04-15 8.1 High
Samsung Galaxy Buds and Galaxy Buds 2 audio devices are Bluetooth pairable by default without user input nor a way to stop this mode. As a consequence, audio playback takeover or even microphone recording without user consent or notification is achieved. Note: This is considered a low severity vulnerability by the vendor.
CVE-2024-56113 2026-04-15 7.5 High
Smart Toilet Lab - Motius 1.3.11 is running with debug mode turned on (DEBUG = True) and exposing sensitive information defined in Django settings file through verbose error page.
CVE-2025-24325 2 Intel, Linux 2 Ethernet 800 Series Software, Linux Kernel 2026-04-15 8.8 High
Improper input validation in the Linux kernel-mode driver for some Intel(R) 800 Series Ethernet before version 1.17.2 may allow an authenticated user to potentially enable escalation of privilege via local access.
CVE-2024-48465 1 Mrbs 1 Mrbs 2026-04-15 9.8 Critical
The MRBS version 1.5.0 has an SQL injection vulnerability in the edit_entry_handler.php file, specifically in the rooms%5B%5D parameter
CVE-2025-5028 2026-04-15 N/A
Installation file of ESET security products on Windows allow an attacker to misuse to delete an arbitrary file without having the permissions to do so.
CVE-2025-43007 2026-04-15 6.3 Medium
SAP Service Parts Management (SPM) does not perform necessary authorization checks for an authenticated user, allowing an attacker to escalate privileges. This has low impact on confidentiality, integrity and availability of the application.
CVE-2025-24323 1 Intel 1 Pcie Switch Software 2026-04-15 6.5 Medium
Improper access control in some firmware package and LED mode toggle tool for some Intel(R) PCIe Switch software before version MR4_1.0b1 may allow a privileged user to potentially enable escalation of privilege via local access.
CVE-2024-45067 2026-04-15 8.2 High
Incorrect default permissions in some Intel(R) Gaudi(R) software installers before version 1.18 may allow an authenticated user to potentially enable escalation of privilege via local access.
CVE-2024-48806 2026-04-15 6.8 Medium
Buffer Overflow vulnerability in Neat Board NFC v.1.20240620.0015 allows a physically proximate attackers to escalate privileges via a crafted payload to the password field
CVE-2025-42998 2026-04-15 5.3 Medium
The security settings in the SAP Business One Integration Framework are not adequately checked, allowing attackers to bypass the 403 Forbidden error and access restricted pages. This leads to low impact on confidentiality of the application, there is no impact on integrity and availability.
CVE-2025-24313 2 Intel, Kubernetes 2 Device Plugins For Kubernetes, Kubernetes 2026-04-15 4.4 Medium
Improper access control for some Device Plugins for Kubernetes software maintained by Intel before version 0.32.0 may allow a privileged user to potentially enable denial of service via local access.
CVE-2025-24303 2 Intel, Linux 2 Ethernet 800 Series Software, Linux Kernel 2026-04-15 7.8 High
Improper check for unusual or exceptional conditions in the Linux kernel-mode driver for some Intel(R) 800 Series Ethernet before version 1.17.2 may allow an authenticated user to potentially enable escalation of privilege via local access.
CVE-2025-24302 1 Intel 1 Tinycbor 2026-04-15 6.7 Medium
Uncontrolled recursion for some TinyCBOR libraries maintained by Intel(R) before version 0.6.1 may allow an authenticated user to potentially enable escalation of privilege via local access.
CVE-2024-43651 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
CVE-2024-42818 1 Fastapi-admin 1 Fastapi-admin Pro 2026-04-15 6.1 Medium
A cross-site scripting (XSS) vulnerability in the Config-Create function of fastapi-admin pro v0.1.4 allows attackers to execute arbitrary web scripts or HTML via a crafted payload injected into the Product Name parameter.
CVE-2024-43650 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-42028 1 Ubiquiti 1 Unifi Network Application 2026-04-15 8.8 High
A Local privilege escalation vulnerability found in a Self-Hosted UniFi Network Server with UniFi Network Application (Version 8.4.62 and earlier) allows a malicious actor with a local operational system user to execute high privilege actions on UniFi Network Server.
CVE-2024-42011 1 Spotify 1 Spotify App 2026-04-15 7.5 High
The Spotify app 8.9.58 for iOS has a buffer overflow in its use of strcat.